These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 30989088)

  • 1. Intraoperative 360-deg three-dimensional transvaginal ultrasound during needle insertions for high-dose-rate transperineal interstitial gynecologic brachytherapy of vaginal tumors.
    Rodgers JR; Bax J; Surry K; Velker V; Leung E; D'Souza D; Fenster A
    J Med Imaging (Bellingham); 2019 Apr; 6(2):025001. PubMed ID: 30989088
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.
    Rodgers JR; Surry K; Leung E; D'Souza D; Fenster A
    Med Phys; 2017 May; 44(5):1899-1911. PubMed ID: 28295403
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A semiautomatic segmentation method for interstitial needles in intraoperative 3D transvaginal ultrasound images for high-dose-rate gynecologic brachytherapy of vaginal tumors.
    Rodgers JR; Hrinivich WT; Surry K; Velker V; D'Souza D; Fenster A
    Brachytherapy; 2020; 19(5):659-668. PubMed ID: 32631651
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical implementation of 3D transvaginal ultrasound for intraoperative guidance of needle implant in template interstitial gynecologic high-dose-rate brachytherapy.
    Van Elburg D; Meyer T; Martell K; Quirk S; Banerjee R; Phan T; Fenster A; Roumeliotis M
    Brachytherapy; 2023; 22(6):790-799. PubMed ID: 37722991
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A power Doppler ultrasound method for improving intraoperative tip localization for visually obstructed needles in interstitial prostate brachytherapy.
    Orlando N; Snir J; Barker K; D'Souza D; Velker V; Mendez LC; Fenster A; Hoover DA
    Med Phys; 2023 May; 50(5):2649-2661. PubMed ID: 36846880
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and clinical implementation of simple needle attachment post placement interstitial template (SNAPP-IT) enabling a shorter, more direct needle path while preserving tumor visualization.
    Baniel CC; Hui C; Franco PA; Niedermayr T; Kidd EA
    Brachytherapy; 2024; 23(2):149-153. PubMed ID: 38160101
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new technique for performing interstitial implants for gynecologic malignancies using transvaginal ultrasound guidance.
    Yan XJ; Yang Y; Chen X; Wang SG; Niu SH; Niu HX; Liu H
    Front Oncol; 2022; 12():858620. PubMed ID: 36033491
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical note: Commissioning of an ultrasound-compatible surrogate vaginal cylinder for transvaginal ultrasound-based gynecologic high-dose-rate brachytherapy.
    Van Elburg D; Roumeliotis M; Fenster A; Phan T; Meyer T
    Med Phys; 2022 Apr; 49(4):2203-2211. PubMed ID: 35199856
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outpatient template-guided permanent interstitial brachytherapy using
    Feddock J; Aryal P; Steber C; Edwards J; Cheek D; Randall M
    Brachytherapy; 2017; 16(2):393-401. PubMed ID: 28139423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Verification of needle guidance accuracy in pelvic phantom using registered ultrasound and MRI images for intracavitary/interstitial gynecologic brachytherapy.
    Yang Z; Liu Z; Jiang S; Zeng J; Hu Y; Zhang G
    J Contemp Brachytherapy; 2020 Apr; 12(2):147-159. PubMed ID: 32395139
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new technique for performing Syed-Neblett template interstitial implants for gynecologic malignancies using transrectal-ultrasound guidance.
    Stock RG; Chan K; Terk M; Dewyngaert JK; Stone NN; Dottino P
    Int J Radiat Oncol Biol Phys; 1997 Mar; 37(4):819-25. PubMed ID: 9128957
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of fluoroscopy to guide needle placement in interstitial gynecological brachytherapy.
    Nag S; Martínez-Monge R; Ellis R; Lewandowski G; Vacarello L; Boutselis JG; Copeland L
    Int J Radiat Oncol Biol Phys; 1998 Jan; 40(2):415-20. PubMed ID: 9457830
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional transrectal ultrasound guided high-dose-rate prostate brachytherapy: A comparison of needle segmentation accuracy with two-dimensional image guidance.
    Hrinivich WT; Hoover DA; Surry K; Edirisinghe C; Montreuil J; D'Souza D; Fenster A; Wong E
    Brachytherapy; 2016; 15(2):231-9. PubMed ID: 26832673
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potential decreased morbidity of interstitial brachytherapy for gynecologic malignancies using laparoscopy: A pilot study.
    Choi JC; Ingenito AC; Nanda RK; Smith DH; Wuu CS; Chin LJ; Schiff PB
    Gynecol Oncol; 1999 May; 73(2):210-5. PubMed ID: 10329036
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrasound-guided interstitial brachytherapy in the treatment of advanced vaginal recurrences from cervical and endometrial carcinoma.
    Weitmann HD; Knocke TH; Waldhäusl C; Pötter R
    Strahlenther Onkol; 2006 Feb; 182(2):86-95. PubMed ID: 16447015
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implementation of 3D-virtual brachytherapy in the management of breast cancer: a description of a new method of interstitial brachytherapy.
    Vicini FA; Jaffray DA; Horwitz EM; Edmundson GK; DeBiose DA; Kini VR; Martinez AA
    Int J Radiat Oncol Biol Phys; 1998 Feb; 40(3):629-35. PubMed ID: 9486613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel ultrasound probe calibration method for multimodal image guidance of needle placement in cervical cancer brachytherapy.
    Pu G; Jiang S; Yang Z; Hu Y; Liu Z
    Phys Med; 2022 Aug; 100():81-89. PubMed ID: 35759943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy and variability of high-dose-rate prostate brachytherapy needle tip localization using live two-dimensional and sagittally reconstructed three-dimensional ultrasound.
    Hrinivich WT; Hoover DA; Surry K; Edirisinghe C; Velker V; Bauman G; D'Souza D; Fenster A; Wong E
    Brachytherapy; 2017; 16(5):1035-1043. PubMed ID: 28764882
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperative optimization of needle placement and dwell times for conformal prostate brachytherapy.
    Edmundson GK; Yan D; Martinez AA
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1257-63. PubMed ID: 7493850
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous automatic segmentation of multiple needles using 3D ultrasound for high-dose-rate prostate brachytherapy.
    Hrinivich WT; Hoover DA; Surry K; Edirisinghe C; Montreuil J; D'Souza D; Fenster A; Wong E
    Med Phys; 2017 Apr; 44(4):1234-1245. PubMed ID: 28160517
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.