136 related articles for article (PubMed ID: 3099146)
1. Determinations of Ngas and Prepl factors from commercially available parallel-plate chambers: AAPM Task Group 21 protocol.
Kubo H; Kent LJ; Krithivas G
Med Phys; 1986; 13(6):908-12. PubMed ID: 3099146
[TBL] [Abstract][Full Text] [Related]
2. The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams: an extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No. 39.
Almond PR; Attix FH; Humphries LJ; Kubo H; Nath R; Goetsch S; Rogers DW
Med Phys; 1994 Aug; 21(8):1251-60. PubMed ID: 7799867
[TBL] [Abstract][Full Text] [Related]
3. Comparative Ngas measurements for a parallel plate chamber in proton, electron, and 60Co beams.
Wu GN; Sandison GA; Bloch C
Med Phys; 1995 Dec; 22(12):2057-63. PubMed ID: 8746711
[TBL] [Abstract][Full Text] [Related]
4. A comparison of methods for calibrating parallel-plate chambers/.
Reft CS; Kuchnir FT; DeWerd LA; Micka J; Attix FH
Med Phys; 1994 Dec; 21(12):1953-7. PubMed ID: 7700203
[TBL] [Abstract][Full Text] [Related]
5. Replacement correction factors for electron measurements with a parallel-plate chamber.
Casson H; Kiley JP
Med Phys; 1987; 14(2):216-7. PubMed ID: 3587141
[TBL] [Abstract][Full Text] [Related]
6. Ngas determination for a parallel-plate ion chamber.
Krithivas G; Rao SN
Med Phys; 1986; 13(5):674-7. PubMed ID: 3784995
[TBL] [Abstract][Full Text] [Related]
7. Calibration of parallel-plate chambers: resolution of several problems by using Monte Carlo calculations.
Rogers DW
Med Phys; 1992; 19(4):889-99. PubMed ID: 1518477
[TBL] [Abstract][Full Text] [Related]
8. Measurement of the replacement correction factor for parallel-plate chambers in electron fields.
Reft CS; Kuchnir FT
Med Phys; 1991; 18(6):1237-43. PubMed ID: 1753910
[TBL] [Abstract][Full Text] [Related]
9. Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies.
Tailor RC; Hanson WF
Med Phys; 2002 Jul; 29(7):1464-72. PubMed ID: 12148727
[TBL] [Abstract][Full Text] [Related]
10. Measurement of Prepl Pwall factors in electron beams and in a 60Co beam for plane-parallel chambers.
Ding GX; Cygler JE
Med Phys; 1998 Aug; 25(8):1453-7. PubMed ID: 9725133
[TBL] [Abstract][Full Text] [Related]
11. Comparison of IAEA 1987 and AAPM 1983 protocols for dosimetry calibration of radiotherapy beams.
Huq MS; Nath R
Med Phys; 1991; 18(1):26-35. PubMed ID: 1901129
[TBL] [Abstract][Full Text] [Related]
12. Calorimetric determination of the cavity-gas calibration factor Ngas.
Schulz RJ; Weinhous MS
Med Phys; 1985; 12(2):166-8. PubMed ID: 4000071
[TBL] [Abstract][Full Text] [Related]
13. Verification of absorbed doses determined with thimble and parallel-plate ionization chambers in clinical electron beams using ferrous sulphate dosimetry.
Van der Plaetsen A; Seuntjens J; Thierens H; Vynckier S
Med Phys; 1994 Jan; 21(1):37-44. PubMed ID: 8164587
[TBL] [Abstract][Full Text] [Related]
14. Experimental determination of fluence perturbation factors for five parallel-plate ionization chambers.
Kuchnir FT; Reft CS
Med Phys; 1993; 20(2 Pt 1):331-5. PubMed ID: 8497218
[TBL] [Abstract][Full Text] [Related]
15. Ngas values of the Memorial parallel-plate chambers determined in 60Co and high-energy electron beams.
Kubo H
Med Phys; 1991; 18(4):749-52. PubMed ID: 1921881
[TBL] [Abstract][Full Text] [Related]
16. The use of plane-parallel chambers in electron dosimetry without any cross-calibration.
Christ G; Dohm S; Bruggmoser G; Schüle E
Phys Med Biol; 2002 May; 47(9):N121-6. PubMed ID: 12043825
[TBL] [Abstract][Full Text] [Related]
17. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
Saiful Huq M; Song H; Andreo P; Houser CJ
Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769
[TBL] [Abstract][Full Text] [Related]
18. Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols.
Stewart KJ; Seuntjens JP
Med Phys; 2002 Mar; 29(3):284-9. PubMed ID: 11929010
[TBL] [Abstract][Full Text] [Related]
19. Clinical reference dosimetry: comparison between AAPM TG-21 and TG-51 protocols.
Ding GX; Cygler JE; Kwok CB
Med Phys; 2000 Jun; 27(6):1217-25. PubMed ID: 10902550
[TBL] [Abstract][Full Text] [Related]
20. Comparison of high-energy photon and electron dosimetry for various dosimetry protocols.
Araki F; Kubo HD
Med Phys; 2002 May; 29(5):857-68. PubMed ID: 12033582
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]