These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 30997755)

  • 1. Carbon dioxide diffusion coefficient in noninvasive high-frequency oscillatory ventilation.
    Schäfer C; Schumann S; Fuchs H; Klotz D
    Pediatr Pulmonol; 2019 Jun; 54(6):759-764. PubMed ID: 30997755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Leakage in nasal high-frequency oscillatory ventilation improves carbon dioxide clearance-A bench study.
    Klotz D; Schaefer C; Stavropoulou D; Fuchs H; Schumann S
    Pediatr Pulmonol; 2017 Mar; 52(3):367-372. PubMed ID: 27526104
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of amplitude and inspiratory time in a bench model of non-invasive HFOV through nasal prongs.
    De Luca D; Piastra M; Pietrini D; Conti G
    Pediatr Pulmonol; 2012 Oct; 47(10):1012-8. PubMed ID: 22328295
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effective Tidal Volume for Normocapnia in Very-Low-Birth-Weight Infants Using High-Frequency Oscillatory Ventilation.
    Lee SM; Namgung R; Eun HS; Lee SM; Park MS; Park KI
    Yonsei Med J; 2018 Jan; 59(1):101-106. PubMed ID: 29214783
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Weight-correction of carbon dioxide diffusion coefficient (DCO
    Belteki G; Lin B; Morley CJ
    Pediatr Pulmonol; 2017 Oct; 52(10):1316-1322. PubMed ID: 28682001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive high frequency oscillatory ventilation through nasal prongs: bench evaluation of efficacy and mechanics.
    De Luca D; Carnielli VP; Conti G; Piastra M
    Intensive Care Med; 2010 Dec; 36(12):2094-100. PubMed ID: 20857278
    [TBL] [Abstract][Full Text] [Related]  

  • 7. DCO
    González-Pacheco N; Sánchez-Luna M; Arribas-Sánchez C; Santos-González M; Orden-Quinto C; Tendillo-Cortijo F
    Eur J Pediatr; 2020 Mar; 179(3):499-506. PubMed ID: 31823075
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nasal high-frequency oscillatory ventilation and CO
    Bottino R; Pontiggia F; Ricci C; Gambacorta A; Paladini A; Chijenas V; Liubsys A; Navikiene J; Pliauckiene A; Mercadante D; Colnaghi M; Tana M; Tirone C; Lio A; Aurilia C; Pastorino R; Purcaro V; Maffei G; Liberatore P; Consigli C; Haass C; Lista G; Agosti M; Mosca F; Vento G
    Pediatr Pulmonol; 2018 Sep; 53(9):1245-1251. PubMed ID: 29999596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nasal high-frequency oscillatory ventilation impairs heated humidification: A neonatal bench study.
    Ullrich TL; Czernik C; Bührer C; Schmalisch G; Fischer HS
    Pediatr Pulmonol; 2017 Nov; 52(11):1455-1460. PubMed ID: 28881101
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
    Delgado E; Hete B; Hoffman LA; Tasota FJ; Pinsky MR
    Respir Care; 2001 Jun; 46(6):577-85. PubMed ID: 11353546
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of the I/E ratio on CO2 removal during high-frequency oscillatory ventilation with volume guarantee in a neonatal animal model of RDS.
    Sánchez-Luna M; González-Pacheco N; Santos M; Blanco Á; Orden C; Belik J; Tendillo FJ
    Eur J Pediatr; 2016 Oct; 175(10):1343-51. PubMed ID: 27595847
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study.
    Singh R; Courtney SE; Weisner MD; Habib RH
    J Appl Physiol (1985); 2012 Apr; 112(7):1105-13. PubMed ID: 22207721
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Oscillation transmission and volume delivery during face mask-delivered HFOV in infants: Bench and in vivo study.
    De Luca D; Costa R; Visconti F; Piastra M; Conti G
    Pediatr Pulmonol; 2016 Jul; 51(7):705-12. PubMed ID: 26918535
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A noninvasive high frequency oscillation ventilator: Achieved by utilizing a blower and a valve.
    Yuan Y; Sun J; Wang B; Feng P; Yang C
    Rev Sci Instrum; 2016 Feb; 87(2):025113. PubMed ID: 26931897
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accumulation of CO(2) in reservoir devices during simulated neonatal mechanical ventilation.
    Lugo RA; Keenan J; Salyer JW
    Pediatr Pulmonol; 2000 Dec; 30(6):470-5. PubMed ID: 11109059
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unpredictability of delivered bubble nasal continuous positive airway pressure: role of bias flow magnitude and nares-prong air leaks.
    Kahn DJ; Courtney SE; Steele AM; Habib RH
    Pediatr Res; 2007 Sep; 62(3):343-7. PubMed ID: 17622958
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inspiratory limb carbon dioxide entrainment during high-frequency oscillatory ventilation: characterization in a mechanical test lung and swine model.
    Bostick AW; Naworol GA; Britton TJ; Ori TR; French SK; Derdak S
    Respir Care; 2012 Nov; 57(11):1865-72. PubMed ID: 22613503
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of Reported Tidal Volume During Neonatal Ventilation With Airway Leak: A Lung Model Study.
    Moon K; Takeuchi M; Tachibana K; Mizuguchi S; Hirano S
    Pediatr Crit Care Med; 2019 Jan; 20(1):e37-e45. PubMed ID: 30335665
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model.
    Johannes A; Zollhoefer B; Eujen U; Kredel M; Rauch S; Roewer N; Muellenbach RM
    Exp Lung Res; 2013 Apr; 39(3):130-5. PubMed ID: 23458472
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance.
    Grazioli S; Karam O; Rimensberger PC
    Respir Care; 2015 Mar; 60(3):363-70. PubMed ID: 25406342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.