These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 30999138)

  • 1. Electrocoagulation using stainless steel anodes: Simultaneous removal of phosphates, Orange II and zinc ions.
    Dura A; Breslin CB
    J Hazard Mater; 2019 Jul; 374():152-158. PubMed ID: 30999138
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrocoagulation using aluminium anodes activated with Mg, In and Zn alloying elements.
    Dura A; Breslin CB
    J Hazard Mater; 2019 Mar; 366():39-45. PubMed ID: 30502571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metal release rate from AISI 316L stainless steel and pure Fe, Cr and Ni into a synthetic biological medium--a comparison.
    Herting G; Wallinder IO; Leygraf C
    J Environ Monit; 2008 Sep; 10(9):1092-8. PubMed ID: 18728903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Corrosion Resistance of AISI 442 and AISI 446 Ferritic Stainless Steels as a Support for PEMWE Bipolar Plates.
    Dan ML; Kellenberger A; Duca D; Vaszilcsin N; Craciunescu CM; Mitelea I; Ercuta A; Lædre S; Khoza T
    Materials (Basel); 2023 Feb; 16(4):. PubMed ID: 36837131
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Particles, sweat, and tears: a comparative study on bioaccessibility of ferrochromium alloy and stainless steel particles, the pure metals and their metal oxides, in simulated skin and eye contact.
    Hedberg Y; Midander K; Wallinder IO
    Integr Environ Assess Manag; 2010 Jul; 6(3):456-68. PubMed ID: 20821707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nickel release from stainless steels.
    Haudrechy P; Mantout B; Frappaz A; Rousseau D; Chabeau G; Faure M; Claudy A
    Contact Dermatitis; 1997 Sep; 37(3):113-7. PubMed ID: 9330816
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Adsorption and protein-induced metal release from chromium metal and stainless steel.
    Lundin M; Hedberg Y; Jiang T; Herting G; Wang X; Thormann E; Blomberg E; Wallinder IO
    J Colloid Interface Sci; 2012 Jan; 366(1):155-164. PubMed ID: 22014396
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro osteoblastic differentiation of human bone marrow cells in the presence of metal ions.
    Morais S; Dias N; Sousa JP; Fernandes MH; Carvalho GS
    J Biomed Mater Res; 1999 Feb; 44(2):176-90. PubMed ID: 10397919
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Remediation of phosphate-contaminated water by electrocoagulation with aluminium, aluminium alloy and mild steel anodes.
    Vasudevan S; Lakshmi J; Jayaraj J; Sozhan G
    J Hazard Mater; 2009 May; 164(2-3):1480-6. PubMed ID: 18977084
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion behavior of 2205 duplex stainless steel.
    Platt JA; Guzman A; Zuccari A; Thornburg DW; Rhodes BF; Oshida Y; Moore BK
    Am J Orthod Dentofacial Orthop; 1997 Jul; 112(1):69-79. PubMed ID: 9228844
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion Behavior of AISI 304 Stainless Steel Reinforcements in SCBA-SF Ternary Ecological Concrete Exposed to MgSO
    Ariza-Figueroa HA; Bosch J; Baltazar-Zamora MA; Croche R; Santiago-Hurtado G; Landa-Ruiz L; Mendoza-Rangel JM; Bastidas JM; Almeraya-Calderón F; Bastidas DM
    Materials (Basel); 2020 May; 13(10):. PubMed ID: 32456331
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of Cathodic Polarisation Switch-Off on the Passivity and Stability to Crevice Corrosion of AISI 304L Stainless Steel.
    Shubina Helbert V; Nazarov A; Vucko F; Larché N; Thierry D
    Materials (Basel); 2021 May; 14(11):. PubMed ID: 34071568
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laser Dissimilar Welding of AISI 430F and AISI 304 Stainless Steels.
    Pańcikiewicz K; Świerczyńska A; Hućko P; Tumidajewicz M
    Materials (Basel); 2020 Oct; 13(20):. PubMed ID: 33066116
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of pH and chloride concentration on the removal of hexavalent chromium in a batch electrocoagulation reactor.
    Arroyo MG; Pérez-Herranz V; Montañés MT; García-Antón J; Guiñón JL
    J Hazard Mater; 2009 Sep; 169(1-3):1127-33. PubMed ID: 19464794
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Enhanced Pitting Corrosion Resistance of Nanostructured AISI 304 Stainless Steel via Pipe Inner Surface Grinding Treatment.
    Han X; Wei P; Zhao Y; Wang Z; Li C; Wu X; Zhang H
    Nanomaterials (Basel); 2023 Jan; 13(2):. PubMed ID: 36678073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Datasets on the corrosion behaviour of nanostructured AISI 316 stainless steel treated by SMAT.
    Olugbade T
    Data Brief; 2019 Aug; 25():104033. PubMed ID: 31194140
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Structural and Micromechanical Properties of Nd:YAG Laser Marking Stainless Steel (AISI 304 and AISI 316).
    Dywel P; Szczesny R; Domanowski P; Skowronski L
    Materials (Basel); 2020 May; 13(9):. PubMed ID: 32397117
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores.
    Black E; Owens K; Staub R; Li J; Mills K; Valenstein J; Hilgren J
    PLoS One; 2017; 12(10):e0187074. PubMed ID: 29065168
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The mechanism of transcatheter electrocoagulation (TCEC).
    Philpott CC; Hirschfeld B; Clark HC; Thompson WM
    Invest Radiol; 1983; 18(1):100-4. PubMed ID: 6832924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamics of Chromium(VI) Removal from Drinking Water by Iron Electrocoagulation.
    Pan C; Troyer LD; Catalano JG; Giammar DE
    Environ Sci Technol; 2016 Dec; 50(24):13502-13510. PubMed ID: 27993045
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.