These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 31000367)

  • 21. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.
    Yu CH; Su PL; Lin WC; Lin SH; Chen CW
    Respir Care; 2015 Feb; 60(2):201-9. PubMed ID: 25371401
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease.
    Kimball WR; Leith DE; Robins AG
    Am Rev Respir Dis; 1982 Dec; 126(6):991-5. PubMed ID: 6960747
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of the Pneupac Ventipac portable ventilator: comparison of performance in a mechanical lung and anaesthetized patients.
    McCluskey A; Gwinnutt CL
    Br J Anaesth; 1995 Nov; 75(5):645-50. PubMed ID: 7577298
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [The appraisal of role of power in end-inspiratory plateau (EIP) on ventilator, and airway dynamics (author's transl)].
    Mima M; Imanishi T; Taguchi H
    Kokyu To Junkan; 1981 Sep; 29(9):949-55. PubMed ID: 6948334
    [No Abstract]   [Full Text] [Related]  

  • 25. Comparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators.
    Gonzales JF; Russian CJ; Gregg Marshall S; Collins KP
    Respir Care; 2013 Mar; 58(3):465-73. PubMed ID: 22781498
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Validation of respiratory mechanics software in microprocessor-controlled ventilators.
    Korst RJ; Orlando R; Yeston NS; Molin M; de Graff AC; Gluck E
    Crit Care Med; 1992 Aug; 20(8):1152-6. PubMed ID: 1643895
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours.
    Craven DE; Connolly MG; Lichtenberg DA; Primeau PJ; McCabe WR
    N Engl J Med; 1982 Jun; 306(25):1505-9. PubMed ID: 7043269
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration.
    Campbell RS; Johannigman JA; Branson RD; Austin PN; Matacia G; Banks GR
    Respir Care; 2002 Oct; 47(10):1173-83. PubMed ID: 12354337
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reliability of Tidal Volume in Average Volume Assured Pressure Support Mode.
    Stagnara A; Baboi L; Nesme P; Subtil F; Louis B; Guérin C
    Respir Care; 2018 Sep; 63(9):1139-1146. PubMed ID: 29921607
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Leak compensation in positive pressure ventilators: a lung model study.
    Mehta S; McCool FD; Hill NS
    Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Laboratory evaluation of the SAVe simplified automated resuscitator.
    Blakeman T; Rodriquez D; Petro M; Dorlac W; Branson R
    Mil Med; 2011 Jan; 176(1):84-8. PubMed ID: 21305965
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Compression volume during mechanical ventilation: comparison of ventilators and tubing circuits.
    Bartel LP; Bazik JR; Powner DJ
    Crit Care Med; 1985 Oct; 13(10):851-4. PubMed ID: 3861291
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Bench performance of ventilators during simulated paediatric ventilation.
    Park MA; Freebairn RC; Gomersall CD
    Anaesth Intensive Care; 2013 May; 41(3):349-58. PubMed ID: 23659397
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Performance of transport ventilator with patient-triggered ventilation.
    Miyoshi E; Fujino Y; Mashimo T; Nishimura M
    Chest; 2000 Oct; 118(4):1109-15. PubMed ID: 11035686
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of inspiratory rise time on triggering work load during pressure-support ventilation: a lung model study.
    Murata S; Yokoyama K; Sakamoto Y; Yamashita K; Oto J; Imanaka H; Nishimura M
    Respir Care; 2010 Jul; 55(7):878-84. PubMed ID: 20587100
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of insufflation leaks upon ventilation. A quantified comparison of ventilators.
    Watt JW; Fraser MH
    Anaesthesia; 1994 Apr; 49(4):320-3. PubMed ID: 8179141
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An investigation of the early effects of manual lung hyperinflation in critically ill patients.
    Hodgson C; Denehy L; Ntoumenopoulos G; Santamaria J; Carroll S
    Anaesth Intensive Care; 2000 Jun; 28(3):255-61. PubMed ID: 10853205
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance of neonatal ventilators in volume targeted ventilation mode.
    Sharma A; Milner AD; Greenough A
    Acta Paediatr; 2007 Feb; 96(2):176-80. PubMed ID: 17429900
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The MIE Carden ventilator. A description and laboratory assessment.
    Fletcher IR; Carden E; Healy TE; Poole TR
    Anaesthesia; 1983 Nov; 38(11):1082-9. PubMed ID: 6579861
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Modified interface between pediatric ventilator and Ayre's T-piece for use in neonates.
    el-Attar AM
    Middle East J Anaesthesiol; 1996 Feb; 13(4):395-403. PubMed ID: 8713634
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.