111 related articles for article (PubMed ID: 31000367)
21. Simulation of late inspiratory rise in airway pressure during pressure support ventilation. Yu CH; Su PL; Lin WC; Lin SH; Chen CW Respir Care; 2015 Feb; 60(2):201-9. PubMed ID: 25371401 [TBL] [Abstract][Full Text] [Related]
22. Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease. Kimball WR; Leith DE; Robins AG Am Rev Respir Dis; 1982 Dec; 126(6):991-5. PubMed ID: 6960747 [TBL] [Abstract][Full Text] [Related]
23. Evaluation of the Pneupac Ventipac portable ventilator: comparison of performance in a mechanical lung and anaesthetized patients. McCluskey A; Gwinnutt CL Br J Anaesth; 1995 Nov; 75(5):645-50. PubMed ID: 7577298 [TBL] [Abstract][Full Text] [Related]
24. [The appraisal of role of power in end-inspiratory plateau (EIP) on ventilator, and airway dynamics (author's transl)]. Mima M; Imanishi T; Taguchi H Kokyu To Junkan; 1981 Sep; 29(9):949-55. PubMed ID: 6948334 [No Abstract] [Full Text] [Related]
25. Comparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators. Gonzales JF; Russian CJ; Gregg Marshall S; Collins KP Respir Care; 2013 Mar; 58(3):465-73. PubMed ID: 22781498 [TBL] [Abstract][Full Text] [Related]
26. Validation of respiratory mechanics software in microprocessor-controlled ventilators. Korst RJ; Orlando R; Yeston NS; Molin M; de Graff AC; Gluck E Crit Care Med; 1992 Aug; 20(8):1152-6. PubMed ID: 1643895 [TBL] [Abstract][Full Text] [Related]
27. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. Craven DE; Connolly MG; Lichtenberg DA; Primeau PJ; McCabe WR N Engl J Med; 1982 Jun; 306(25):1505-9. PubMed ID: 7043269 [TBL] [Abstract][Full Text] [Related]
28. Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration. Campbell RS; Johannigman JA; Branson RD; Austin PN; Matacia G; Banks GR Respir Care; 2002 Oct; 47(10):1173-83. PubMed ID: 12354337 [TBL] [Abstract][Full Text] [Related]
30. Leak compensation in positive pressure ventilators: a lung model study. Mehta S; McCool FD; Hill NS Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129 [TBL] [Abstract][Full Text] [Related]
31. Laboratory evaluation of the SAVe simplified automated resuscitator. Blakeman T; Rodriquez D; Petro M; Dorlac W; Branson R Mil Med; 2011 Jan; 176(1):84-8. PubMed ID: 21305965 [TBL] [Abstract][Full Text] [Related]
32. Compression volume during mechanical ventilation: comparison of ventilators and tubing circuits. Bartel LP; Bazik JR; Powner DJ Crit Care Med; 1985 Oct; 13(10):851-4. PubMed ID: 3861291 [TBL] [Abstract][Full Text] [Related]
33. Bench performance of ventilators during simulated paediatric ventilation. Park MA; Freebairn RC; Gomersall CD Anaesth Intensive Care; 2013 May; 41(3):349-58. PubMed ID: 23659397 [TBL] [Abstract][Full Text] [Related]
34. Performance of transport ventilator with patient-triggered ventilation. Miyoshi E; Fujino Y; Mashimo T; Nishimura M Chest; 2000 Oct; 118(4):1109-15. PubMed ID: 11035686 [TBL] [Abstract][Full Text] [Related]
35. Effects of inspiratory rise time on triggering work load during pressure-support ventilation: a lung model study. Murata S; Yokoyama K; Sakamoto Y; Yamashita K; Oto J; Imanaka H; Nishimura M Respir Care; 2010 Jul; 55(7):878-84. PubMed ID: 20587100 [TBL] [Abstract][Full Text] [Related]
36. The effect of insufflation leaks upon ventilation. A quantified comparison of ventilators. Watt JW; Fraser MH Anaesthesia; 1994 Apr; 49(4):320-3. PubMed ID: 8179141 [TBL] [Abstract][Full Text] [Related]
37. An investigation of the early effects of manual lung hyperinflation in critically ill patients. Hodgson C; Denehy L; Ntoumenopoulos G; Santamaria J; Carroll S Anaesth Intensive Care; 2000 Jun; 28(3):255-61. PubMed ID: 10853205 [TBL] [Abstract][Full Text] [Related]
38. Performance of neonatal ventilators in volume targeted ventilation mode. Sharma A; Milner AD; Greenough A Acta Paediatr; 2007 Feb; 96(2):176-80. PubMed ID: 17429900 [TBL] [Abstract][Full Text] [Related]
39. The MIE Carden ventilator. A description and laboratory assessment. Fletcher IR; Carden E; Healy TE; Poole TR Anaesthesia; 1983 Nov; 38(11):1082-9. PubMed ID: 6579861 [TBL] [Abstract][Full Text] [Related]
40. Modified interface between pediatric ventilator and Ayre's T-piece for use in neonates. el-Attar AM Middle East J Anaesthesiol; 1996 Feb; 13(4):395-403. PubMed ID: 8713634 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]