These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 31000909)

  • 1. Preliminary Results Comparing Thin Plate Splines with Finite Element Methods for Modeling Brain Deformation during Neurosurgery using Intraoperative Ultrasound.
    Frisken S; Luo M; Machado I; Unadkat P; Juvekar P; Bunevicius A; Toews M; Wells WM; Miga MI; Golby AJ
    Proc SPIE Int Soc Opt Eng; 2019 Feb; 10951():. PubMed ID: 31000909
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of thin-plate spline deformation and finite element modeling to compensate for brain shift during tumor resection.
    Frisken S; Luo M; Juvekar P; Bunevicius A; Machado I; Unadkat P; Bertotti MM; Toews M; Wells WM; Miga MI; Golby AJ
    Int J Comput Assist Radiol Surg; 2020 Jan; 15(1):75-85. PubMed ID: 31444624
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Estimation of intraoperative brain shift by combination of stereovision and doppler ultrasound: phantom and animal model study.
    Mohammadi A; Ahmadian A; Azar AD; Sheykh AD; Amiri F; Alirezaie J
    Int J Comput Assist Radiol Surg; 2015 Nov; 10(11):1753-64. PubMed ID: 25958061
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Non-rigid registration of 3D ultrasound for neurosurgery using automatic feature detection and matching.
    Machado I; Toews M; Luo J; Unadkat P; Essayed W; George E; Teodoro P; Carvalho H; Martins J; Golland P; Pieper S; Frisken S; Golby A; Wells W
    Int J Comput Assist Radiol Surg; 2018 Oct; 13(10):1525-1538. PubMed ID: 29869321
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative image updating for brain shift following dural opening.
    Fan X; Roberts DW; Schaewe TJ; Ji S; Holton LH; Simon DA; Paulsen KD
    J Neurosurg; 2017 Jun; 126(6):1924-1933. PubMed ID: 27611206
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Serial registration of intraoperative MR images of the brain.
    Ferrant M; Nabavi A; Macq B; Black PM; Jolesz FA; Kikinis R; Warfield SK
    Med Image Anal; 2002 Dec; 6(4):337-59. PubMed ID: 12426109
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accounting for intraoperative brain shift ascribable to cavity collapse during intracranial tumor resection.
    Narasimhan S; Weis JA; Luo M; Simpson AL; Thompson RC; Miga MI
    J Med Imaging (Bellingham); 2020 May; 7(3):031506. PubMed ID: 32613027
    [No Abstract]   [Full Text] [Related]  

  • 8. Clinical evaluation of a model-updated image-guidance approach to brain shift compensation: experience in 16 cases.
    Miga MI; Sun K; Chen I; Clements LW; Pheiffer TS; Simpson AL; Thompson RC
    Int J Comput Assist Radiol Surg; 2016 Aug; 11(8):1467-74. PubMed ID: 26476637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 2D XFEM-based modeling of retraction and successive resections for preoperative image update.
    Vigneron LM; Duflot MP; Robe PA; Warfield SK; Verly JG
    Comput Aided Surg; 2009; 14(1-3):1-20. PubMed ID: 19634040
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Brain-shift compensation using intraoperative ultrasound and constraint-based biomechanical simulation.
    Morin F; Courtecuisse H; Reinertsen I; Le Lann F; Palombi O; Payan Y; Chabanas M
    Med Image Anal; 2017 Aug; 40():133-153. PubMed ID: 28651099
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy.
    van de Ven WJ; Hu Y; Barentsz JO; Karssemeijer N; Barratt D; Huisman HJ
    Med Phys; 2015 May; 42(5):2470-81. PubMed ID: 25979040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-rigid deformation pipeline for compensation of superficial brain shift.
    Marreiros FM; Rossitti S; Wang C; Smedby Ö
    Med Image Comput Comput Assist Interv; 2013; 16(Pt 2):141-8. PubMed ID: 24579134
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fast and adaptive finite element approach for modeling brain shift.
    Soza G; Grosso R; Labsik U; Nimsky C; Fahlbusch R; Greiner G; Hastreiter P
    Comput Aided Surg; 2003; 8(5):241-6. PubMed ID: 15529953
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A machine learning approach for real-time modelling of tissue deformation in image-guided neurosurgery.
    Tonutti M; Gras G; Yang GZ
    Artif Intell Med; 2017 Jul; 80():39-47. PubMed ID: 28750949
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A robust brain deformation framework based on a finite element model in IGNS.
    Liu Y; Song Z
    Int J Med Robot; 2008 Jun; 4(2):146-57. PubMed ID: 18383503
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Augment low-field intra-operative MRI with preoperative MRI using a hybrid non-rigid registration method.
    Yao C; Liu Y; Yao J; Zhuang D; Wu J; Qin Z; Mao Y; Zhou L
    Comput Methods Programs Biomed; 2014 Nov; 117(2):114-24. PubMed ID: 25178268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrospective study comparing model-based deformation correction to intraoperative magnetic resonance imaging for image-guided neurosurgery.
    Luo M; Frisken SF; Weis JA; Clements LW; Unadkat P; Thompson RC; Golby AJ; Miga MI
    J Med Imaging (Bellingham); 2017 Jul; 4(3):035003. PubMed ID: 28924573
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Model-Updated Image-Guided Neurosurgery: Preliminary Analysis Using Intraoperative MR.
    Miga MI; Staubert A; Paulsen KD; Kennedy FE; Tronnier VM; Roberts DW; Hartov A; Platenik LA; Lunn KE
    Med Image Comput Comput Assist Interv; 2000 Oct; 1935():115-124. PubMed ID: 26317120
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperatively updated neuroimaging using brain modeling and sparse data.
    Roberts DW; Miga MI; Hartov A; Eisner S; Lemery JM; Kennedy FE; Paulsen KD
    Neurosurgery; 1999 Nov; 45(5):1199-206; discussion 1206-7. PubMed ID: 10549938
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical modeling of the human head for physically based, nonrigid image registration.
    Hagemann A; Rohr K; Stiehl HS; Spetzger U; Gilsbach JM
    IEEE Trans Med Imaging; 1999 Oct; 18(10):875-84. PubMed ID: 10628947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.