These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 31002752)

  • 21. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.
    Arda T; Arikan A
    J Prosthet Dent; 2005 Sep; 94(3):267-74. PubMed ID: 16126079
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials.
    Beuer F; Steff B; Naumann M; Sorensen JA
    Eur J Oral Sci; 2008 Aug; 116(4):381-6. PubMed ID: 18705807
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Zirconia-based fixed partial dentures: a clinical review.
    Bachhav VC; Aras MA
    Quintessence Int; 2011 Feb; 42(2):173-82. PubMed ID: 21359252
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique.
    Zhang M; Gan N; Qian H; Jiao T
    J Prosthodont Res; 2022 Jul; 66(3):459-465. PubMed ID: 34615841
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Interface compatibility between tooth-like yttria-stabilized tetragonal zirconia polycrystal by adding rare-earth oxide and Vita VM9 veneering porcelain].
    Gao Y; Zhang FQ; He F
    Shanghai Kou Qiang Yi Xue; 2011 Oct; 20(5):486-9. PubMed ID: 22109365
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics.
    Fraga S; Amaral M; Bottino MA; Valandro LF; Kleverlaan CJ; May LG
    Dent Mater; 2017 Nov; 33(11):1286-1297. PubMed ID: 28818339
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Macedo AP; de Torres EM; de Mattos Mda G; Ribeiro RF
    Braz Dent J; 2008; 19(3):209-13. PubMed ID: 18949292
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Sintering behavior of tooth-like yttria-stabilized tetragonal zirconia polycrystal by adding rare-earth oxide].
    Gao Y; Zhang FQ; Gao JH
    Shanghai Kou Qiang Yi Xue; 2015 Dec; 24(6):679-86. PubMed ID: 27063118
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.
    Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B
    Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fatigue behavior of removable partial denture cast and laser-sintered cobalt-chromium (CoCr) and polyetheretherketone (PEEK) clasp materials.
    Zheng J; Aarts JM; Ma S; Waddell JN; Choi JJE
    Clin Exp Dent Res; 2022 Dec; 8(6):1496-1504. PubMed ID: 35938907
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering.
    Schweiger J; Güth JF; Erdelt KJ; Edelhoff D; Schubert O
    J Prosthodont Res; 2020 Apr; 64(2):210-216. PubMed ID: 31680054
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sintered Characteristics of 3 Mole% Yttria-Stabilized Zirconia Polycrystals (3Y-TZP) Implants Manufactured by Slip-Casting and Computer Aided Design/Computer Aided Manufacturing (CAD/CAM).
    Kim DS; Lee JK
    J Nanosci Nanotechnol; 2021 Jul; 21(7):3877-3881. PubMed ID: 33715709
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal-Ceramic, Monolithic, and Veneered Zirconia Posterior Fixed Partial Dentures.
    Lopez-Suarez C; Tobar C; Sola-Ruiz MF; Pelaez J; Suarez MJ
    J Prosthodont; 2019 Feb; 28(2):171-178. PubMed ID: 30548895
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp.
    Vallittu PK; Kokkonen M
    J Prosthet Dent; 1995 Oct; 74(4):412-9. PubMed ID: 8531162
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Change in the retentive force of Akers clasp for zirconia crown by repetitive insertion and removal test.
    Tanaka A; Miyake N; Hotta H; Takemoto S; Yoshinari M; Yamashita S
    J Prosthodont Res; 2019 Oct; 63(4):447-452. PubMed ID: 30904359
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fracture strength of yttria-stabilized zirconium-dioxide (Y-TZP) fixed dental prostheses (FDPs) with different abutment core thicknesses and connector dimensions.
    Ambré MJ; Aschan F; Vult von Steyern P
    J Prosthodont; 2013 Jul; 22(5):377-82. PubMed ID: 23289522
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of different polishing protocols on the surface roughness of Y-TZP surfaces used for custom-made implant abutments: a controlled morphologic SEM and profilometric pilot study.
    Happe A; Röling N; Schäfer A; Rothamel D
    J Prosthet Dent; 2015 May; 113(5):440-7. PubMed ID: 25749083
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses.
    Cheng H; Xu M; Zhang H; Wu W; Zheng M; Li X
    J Prosthet Dent; 2010 Dec; 104(6):389-96. PubMed ID: 21095402
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
    Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K
    Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures.
    Tribst JPM; Dal Piva AMO; Borges ALS; Araújo RM; da Silva JMF; Bottino MA; Kleverlaan CJ; de Jager N
    Dent Mater; 2020 Feb; 36(2):179-186. PubMed ID: 31791736
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]