These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 31004852)

  • 21. The silk flow-diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and midterm results in 24 consecutive patients.
    Tähtinen OI; Manninen HI; Vanninen RL; Seppänen J; Niskakangas T; Rinne J; Keski-Nisula L
    Neurosurgery; 2012 Mar; 70(3):617-23; discussion 623-4. PubMed ID: 21866071
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Endovascular management of adjacent tandem intracranial aneurysms: utilization of stent-assisted coiling and flow diversion.
    Lin N; Brouillard AM; Xiang J; Sonig A; Mokin M; Natarajan SK; Krishna C; Hopkins LN; Snyder KV; Siddiqui AH; Levy EI
    Acta Neurochir (Wien); 2015 Mar; 157(3):379-87. PubMed ID: 25572632
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Flow diverter devices in ruptured intracranial aneurysms: a single-center experience.
    Lozupone E; Piano M; Valvassori L; Quilici L; Pero G; Visconti E; Boccardi E
    J Neurosurg; 2018 Apr; 128(4):1037-1043. PubMed ID: 28387623
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Use of flow diverters in the treatment of unruptured saccular aneurysms of the anterior cerebral artery.
    Bhogal P; Martinez Moreno R; Ganslandt O; Bäzner H; Henkes H; Perez MA
    J Neurointerv Surg; 2017 Mar; 9(3):283-289. PubMed ID: 27789789
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Flow diversion of bifurcation aneurysms is more effective when the jailed branch is occluded: an experimental study in a novel canine model.
    Fahed R; Gentric JC; Salazkin I; Gevry G; Raymond J; Darsaut TE
    J Neurointerv Surg; 2017 Mar; 9(3):311-315. PubMed ID: 27067714
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pipeline flow diversion of ruptured blister aneurysms of the supraclinoid carotid artery using a single-device strategy.
    Ryan RW; Khan AS; Barco R; Choulakian A
    Neurosurg Focus; 2017 Jun; 42(6):E11. PubMed ID: 28565992
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Flow Diverter Devices for Treatment of Intracranial Aneurysms in Small Parent Vessels-A Systematic Review of Literature.
    Dabhi N; Sarathy D; Snyder MH; Kellogg RT; Park MS
    World Neurosurg; 2022 Jun; 162():183-194.e7. PubMed ID: 35176522
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents.
    O'kelly CJ; Krings T; Fiorella D; Marotta TR
    Interv Neuroradiol; 2010 Jun; 16(2):133-7. PubMed ID: 20642887
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Management of Unruptured Saccular Aneurysms of the M1 Segment with Flow Diversion : A Single Centre Experience.
    Bhogal P; Martinez R; Gansladt O; Bäzner H; Henkes H; Aguilar M
    Clin Neuroradiol; 2018 Jun; 28(2):209-216. PubMed ID: 27942770
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Endovascular Treatment of Posterior Cerebral Artery Aneurysms With Flow Diversion: Case Series and Systematic Review.
    Wallace AN; Grossberg JA; Almandoz JED; Kamran M; Roy AK; Kayan Y; Austin MJ; Howard BM; Moran CJ; Cawley CM; Cross DT; Dion JE; Kansagra AP; Osbun JW
    Neurosurgery; 2018 Oct; 83(4):790-799. PubMed ID: 29528441
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Diffusion-weighted imaging-detected ischemic lesions associated with flow-diverting stents in intracranial aneurysms: safety, potential mechanisms, clinical outcome, and concerns.
    Iosif C; Camilleri Y; Saleme S; Caire F; Yardin C; Ponomarjova S; Boncoeur-Martel MP; Mounayer C
    J Neurosurg; 2015 Mar; 122(3):627-36. PubMed ID: 25559933
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Single-centre comparison of procedural complications, clinical outcome, and angiographic follow-up between coiling and stent-assisted coiling for posterior communicating artery aneurysms.
    Liu YQ; Wang QJ; Zheng T; Zhang X; Li XF; Cui XB; Gao YY; Lai LF; Su SX; He XY; Duan CZ
    J Clin Neurosci; 2014 Dec; 21(12):2140-4. PubMed ID: 25037315
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up.
    Fiorella D; Albuquerque FC; Deshmukh VR; McDougall CG
    Neurosurgery; 2005 Jun; 56(6):1191-201; discussion 1201-2. PubMed ID: 15918935
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Long-term follow-up in the endovascular treatment of intracranial aneurysms with flow-diverter stents: update of a single-centre experience.
    Guzzardi G; Stanca C; Cerini P; Del Sette B; Divenuto I; Malatesta E; Carriero A; Stecco A
    Radiol Med; 2018 Jun; 123(6):449-455. PubMed ID: 29380260
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Reconstructive endovascular treatment of intracranial aneurysms with the Willis covered stent: medium-term clinical and angiographic follow-up.
    Tan HQ; Li MH; Zhang PL; Li YD; Wang JB; Zhu YQ; Wang W
    J Neurosurg; 2011 Apr; 114(4):1014-20. PubMed ID: 20964596
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of Enterprise Stent-Assisted Coiling and Telescoping Stent Technique as Treatment of Supraclinoid Blister Aneurysms of the Internal Carotid Artery.
    Xu D; Zhang C; Wang T; Wang C; Kallmes DF; Lanzino G; You C; Xie X
    World Neurosurg; 2018 Feb; 110():e890-e896. PubMed ID: 29191548
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Endovascular Treatment of Wide-Necked Intracranial Aneurysms with the Scepter XC Balloon Catheter, with Low-Profile Visualized Intraluminal Support (LVIS) Jr. Deployment as a "Bailout" Technique.
    Wallace AN; Kayan Y; Delgado Almandoz JE; Fease JL; Milner AA; Scholz JM
    World Neurosurg; 2019 Jan; 121():e798-e807. PubMed ID: 30312823
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Neck Remnants and the Risk of Aneurysm Rupture After Endovascular Treatment With Coiling or Stent-Assisted Coiling: Much Ado About Nothing?
    Munich SA; Cress MC; Rangel-Castilla L; Sonig A; Ogilvy CS; Lanzino G; Petr O; Mocco J; Morone PJ; Snyder KV; Hopkins LN; Siddiqui AH; Levy EI
    Neurosurgery; 2019 Feb; 84(2):421-427. PubMed ID: 29528449
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Analysis of cerebrovascular aneurysm treatment cost: retrospective cohort comparison of clipping, coiling, and flow diversion.
    Twitchell S; Abou-Al-Shaar H; Reese J; Karsy M; Eli IM; Guan J; Taussky P; Couldwell WT
    Neurosurg Focus; 2018 May; 44(5):E3. PubMed ID: 29712525
    [TBL] [Abstract][Full Text] [Related]  

  • 40. LVIS Jr. stent for treatment of intracranial aneurysms with parent vessel diameter of 2.5 mm or less.
    Santillan A; Boddu S; Schwarz J; Lin N; Gobin YP; Knopman J; Patsalides A
    Interv Neuroradiol; 2018 Jun; 24(3):246-253. PubMed ID: 29463145
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.