These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 31004921)

  • 1. On-line regeneration of electrochemical biosensor for in vivo repetitive measurements of striatum Cu
    Gu H; Hou Q; Liu Y; Cai Y; Guo Y; Xiang H; Chen S
    Biosens Bioelectron; 2019 Jun; 135():111-119. PubMed ID: 31004921
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A selective and accurate ratiometric electrochemical biosensor for monitoring of Cu2+ ions in a rat brain.
    Zhang L; Han Y; Zhao F; Shi G; Tian Y
    Anal Chem; 2015 Mar; 87(5):2931-6. PubMed ID: 25630826
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Regenerative field effect transistor biosensor for in vivo monitoring of dopamine in fish brains.
    Liu N; Xiang X; Fu L; Cao Q; Huang R; Liu H; Han G; Wu L
    Biosens Bioelectron; 2021 Sep; 188():113340. PubMed ID: 34030092
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Functionalized poly (ionic liquid) as the support to construct a ratiometric electrochemical biosensor for the selective determination of copper ions in AD rats.
    Yu Y; Yu C; Yin T; Ou S; Sun X; Wen X; Zhang L; Tang D; Yin X
    Biosens Bioelectron; 2017 Jan; 87():278-284. PubMed ID: 27567254
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Physiologically relevant online electrochemical method for continuous and simultaneous monitoring of striatum glucose and lactate following global cerebral ischemia/reperfusion.
    Lin Y; Zhu N; Yu P; Su L; Mao L
    Anal Chem; 2009 Mar; 81(6):2067-74. PubMed ID: 19281258
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly selective electrochemical strategy for monitoring of cerebral Cu2+ based on a carbon Dot-TPEA hybridized surface.
    Shao X; Gu H; Wang Z; Chai X; Tian Y; Shi G
    Anal Chem; 2013 Jan; 85(1):418-25. PubMed ID: 23214718
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time monitoring of peroxynitrite (ONOO
    Liu F; Dong H; Tian Y
    Analyst; 2019 Mar; 144(6):2150-2157. PubMed ID: 30747187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Facile Ratiometric Electrochemical Sensor for In Vivo/Online Repetitive Measurements of Cerebral Ascorbic Acid in Brain Microdiaysate.
    Jiang Y; Xiao X; Li C; Luo Y; Chen S; Shi G; Han K; Gu H
    Anal Chem; 2020 Mar; 92(5):3981-3989. PubMed ID: 32037799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Label-Free Electrochemical Biosensor for Monitoring of Chloride Ion in an Animal Model of Alzhemier's Disease.
    Dong H; Zhang L; Liu W; Tian Y
    ACS Chem Neurosci; 2017 Feb; 8(2):339-346. PubMed ID: 27992175
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of an Efficient Biosensor for the In Vivo Monitoring of Cu
    Liu W; Dong H; Zhang L; Tian Y
    Angew Chem Int Ed Engl; 2017 Dec; 56(51):16328-16332. PubMed ID: 29115030
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Single Biosensor for Evaluating the Levels of Copper Ion and L-Cysteine in a Live Rat Brain with Alzheimer's Disease.
    Luo Y; Zhang L; Liu W; Yu Y; Tian Y
    Angew Chem Int Ed Engl; 2015 Nov; 54(47):14053-6. PubMed ID: 26486320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined determination of copper ions and β-amyloid peptide by a single ratiometric electrochemical biosensor.
    Yu Y; Wang P; Zhu X; Peng Q; Zhou Y; Yin T; Liang Y; Yin X
    Analyst; 2017 Dec; 143(1):323-331. PubMed ID: 29192910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hybridization of bioelectrochemically functional infinite coordination polymer nanoparticles with carbon nanotubes for highly sensitive and selective in vivo electrochemical monitoring.
    Lu X; Cheng H; Huang P; Yang L; Yu P; Mao L
    Anal Chem; 2013 Apr; 85(8):4007-13. PubMed ID: 23496088
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative study of change in extracellular ascorbic acid in different brain ischemia/reperfusion models with in vivo microdialysis combined with on-line electrochemical detection.
    Liu K; Lin Y; Xiang L; Yu P; Su L; Mao L
    Neurochem Int; 2008 May; 52(6):1247-55. PubMed ID: 18295377
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Micro Electrochemical pH Sensor Applicable for Real-Time Ratiometric Monitoring of pH Values in Rat Brains.
    Zhou J; Zhang L; Tian Y
    Anal Chem; 2016 Feb; 88(4):2113-8. PubMed ID: 26768309
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemin/G-quadruplex-based DNAzyme concatamers for in situ amplified impedimetric sensing of copper(II) ion coupling with DNAzyme-catalyzed precipitation strategy.
    Xu M; Gao Z; Wei Q; Chen G; Tang D
    Biosens Bioelectron; 2015 Dec; 74():1-7. PubMed ID: 26093122
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ratiometric detection of copper ions and alkaline phosphatase activity based on semiconducting polymer dots assembled with rhodamine B hydrazide.
    Sun J; Mei H; Gao F
    Biosens Bioelectron; 2017 May; 91():70-75. PubMed ID: 28012320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Click Chemistry Reaction-Triggered 3D DNA Walking Machine for Sensitive Electrochemical Detection of Copper Ion.
    Qing M; Xie S; Cai W; Tang D; Tang Y; Zhang J; Yuan R
    Anal Chem; 2018 Oct; 90(19):11439-11445. PubMed ID: 30175577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of an electrochemical metal-ion biosensor using self-assembled peptide nanofibrils.
    Viguier B; Zór K; Kasotakis E; Mitraki A; Clausen CH; Svendsen WE; Castillo-León J
    ACS Appl Mater Interfaces; 2011 May; 3(5):1594-600. PubMed ID: 21443268
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Label-free selective impedimetric detection of Cu2+ ions using catalytic DNA.
    Ocaña C; Malashikhina N; del Valle M; Pavlov V
    Analyst; 2013 Apr; 138(7):1995-9. PubMed ID: 23423467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.