These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 31005055)

  • 21. Assessment of the effectiveness of attenuation of Pb aprons by using TLD dosimetry and Monte Carlo calculations.
    Dávila HO; Díaz Merchán JA; Vega Carrillo HR; Martínez Ovalle SA
    Appl Radiat Isot; 2018 Aug; 138():56-59. PubMed ID: 28511893
    [TBL] [Abstract][Full Text] [Related]  

  • 22. On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.
    Bueno M; Carrasco P; Jornet N; Muñoz-Montplet C; Duch MA
    Med Phys; 2014 Aug; 41(8):081710. PubMed ID: 25086520
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Thermoluminescent dosimetry in electron beams: energy dependence.
    Robar V; Zankowski C; Olivares Pla M; Podgorsak EB
    Med Phys; 1996 May; 23(5):667-73. PubMed ID: 8724739
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.
    Konnai A; Nariyama N; Ohnishi S; Odano N
    Radiat Prot Dosimetry; 2005; 115(1-4):334-6. PubMed ID: 16381741
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In-phantom response of LiF TLD-100 for dosimetry of 192Ir HDR source.
    Pradhan AS; Quast U
    Med Phys; 2000 May; 27(5):1025-9. PubMed ID: 10841406
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
    McCaw TJ; Micka JA; DeWerd LA
    Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of lithium co-dopant on the thermoluminescence response of some phosphors.
    Prokić M
    Appl Radiat Isot; 2000 Jan; 52(1):97-103. PubMed ID: 10670929
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance.
    Liuzzi R; Savino F; D'Avino V; Pugliese M; Cella L
    PLoS One; 2015; 10(10):e0139287. PubMed ID: 26427065
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence.
    Alizadeh M; Mohseni M; Farhood B; Aliasgharzadeh A; Moradi H; Ramazani-Moghaddam-Arani A
    J Biomed Phys Eng; 2022 Apr; 12(2):111-116. PubMed ID: 35433523
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of improved TLD dosimetry on the determination of dose rate constants for (125)I and (103)Pd brachytherapy seeds.
    Rodriguez M; Rogers DW
    Med Phys; 2014 Nov; 41(11):114301. PubMed ID: 25370677
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Calculation of the TLD700:LiF energy response from Ir-192 using novel Monte Carlo and empirical methods.
    Rijken JD; Harris-Phillips W; Lawson JM
    Australas Phys Eng Sci Med; 2015 Mar; 38(1):129-38. PubMed ID: 25663432
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte Carlo simulation of correction factors for IAEA TLD holders.
    Hultqvist M; Fernández-Varea JM; Izewska J
    Phys Med Biol; 2010 Mar; 55(6):N161-6. PubMed ID: 20197601
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The influence of neutron contamination on dosimetry in external photon beam radiotherapy.
    Horst F; Czarnecki D; Zink K
    Med Phys; 2015 Nov; 42(11):6529-36. PubMed ID: 26520743
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Type testing of a locally made LiF:Mg,Ti + PTFE TLD for its use as a personal dosimeter.
    Azorín J; Torijano E; Azorín C
    Appl Radiat Isot; 2018 Nov; 141():246-249. PubMed ID: 29843989
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Analysis of neutron and photon response of a TLD-ALBEDO personal dosemeter on an ISO slab phantom using TRIPOLI-4.3 Monte Carlo code.
    Lee YK
    Radiat Prot Dosimetry; 2005; 115(1-4):329-33. PubMed ID: 16381740
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Addressing Current Challenges in OSL Dosimetry Using MgB
    Bossin L; Plokhikh I; Christensen JB; Gawryluk DJ; Kitagawa Y; Leblans P; Tanabe S; Vandenbroucke D; Yukihara EG
    Materials (Basel); 2023 Apr; 16(8):. PubMed ID: 37109886
    [TBL] [Abstract][Full Text] [Related]  

  • 37. On the effect of updated MCNP photon cross section data on the simulated response of the HPA TLD.
    Eakins J
    Radiat Prot Dosimetry; 2009 Feb; 134(1):66-71. PubMed ID: 19386775
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Modeling the thermoluminescent response of CaSO4:Dy by the MCNPX method.
    Furetta C; Roman J; Rivera T; Azorín J; Azorín CG; Vega-Carrillo HR
    Appl Radiat Isot; 2010; 68(4-5):967-9. PubMed ID: 20079655
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dosimetry at the Portuguese research reactor using thermoluminescence measurements and Monte Carlo calculations.
    Fernandes AC; Gonçalves IC; Santos J; Cardoso J; Santos L; Ferro Carvalho A; Marques JG; Kling A; Ramalho AJ; Osvay M
    Radiat Prot Dosimetry; 2006; 120(1-4):349-53. PubMed ID: 16702246
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.
    Jang SY; Liu HH; Mohan R; Siebers JV
    Med Phys; 2007 Apr; 34(4):1388-97. PubMed ID: 17500470
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.