These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 31013800)

  • 1. On-Line Monitoring of Pipe Wall Thinning by a High Temperature Ultrasonic Waveguide System at the Flow Accelerated Corrosion Proof Facility.
    Oh SB; Cheong YM; Kim DJ; Kim KM
    Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31013800
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Error analysis of self-compensated ultrasound measurements of the thickness loss due to corrosion in pipe walls.
    Matuda MY; Pérez N; Buiochi F; Adamowski JC; Tsuzuki MSG
    Ultrasonics; 2024 Aug; 142():107387. PubMed ID: 38971005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonic monitoring of erosion/corrosion thinning rates in industrial piping systems.
    Honarvar F; Salehi F; Safavi V; Mokhtari A; Sinclair AN
    Ultrasonics; 2013 Sep; 53(7):1251-8. PubMed ID: 23601965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal Design Methodology of Tapered Waveguide Transducers for Thickness Monitoring.
    Jia J; Ren Y; Wang W; Liao Z; Zhang X; Tu ST
    Sensors (Basel); 2020 Mar; 20(7):. PubMed ID: 32235338
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flexible metallic ultrasonic transducers for structural health monitoring of pipes at high temperatures.
    Shih JL; Kobayashi M; Jen CK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Sep; 57(9):2103-10. PubMed ID: 20876000
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-temperature (>500°c) wall thickness monitoring using dry-coupled ultrasonic waveguide transducers.
    Cegla FB; Cawley P; Allin J; Davies J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jan; 58(1):156-67. PubMed ID: 21244983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characteristics of high-temperature equipment monitoring using dry-coupled ultrasonic waveguide transducers.
    Liao Z; Zhang X; Liu T; Jia J; Tu ST
    Ultrasonics; 2020 Dec; 108():106236. PubMed ID: 32866941
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous sound velocity and thickness measurement by the ultrasonic pitch-catch method for corrosion-layer-forming polymeric materials.
    Kusano M; Takizawa S; Sakai T; Arao Y; Kubouchi M
    Ultrasonics; 2018 Jan; 82():178-187. PubMed ID: 28869837
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Commercial Corrosion Sensors for Real-Time Monitoring of Pipe Wall Thickness under Various Operational Conditions.
    Shin DH; Hwang HK; Kim HH; Lee JH
    Sensors (Basel); 2022 Oct; 22(19):. PubMed ID: 36236661
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasonic techniques for imaging and measurements in molten aluminum.
    Ono Y; Moisan JF; Jen CK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Dec; 50(12):1711-21. PubMed ID: 14761042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of Waveguide Bars for Transmitting a Pure Shear Horizontal Wave to Monitor High Temperature Components.
    Jia J; Wang Q; Liao Z; Tu Y; Tu ST
    Materials (Basel); 2017 Sep; 10(9):. PubMed ID: 28869554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EMAT design for minimum remnant thickness gauging using high order shear horizontal modes.
    Thon A; Bélanger P
    Ultrasonics; 2019 May; 95():70-78. PubMed ID: 30897386
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Instability of streaks in pipe flow of shear-thinning fluids.
    López Carranza SN; Jenny M; Nouar C
    Phys Rev E Stat Nonlin Soft Matter Phys; 2013 Aug; 88(2):023005. PubMed ID: 24032922
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Applications of flexible ultrasonic transducer array for defect detection at 150 °C.
    Shih JL; Wu KT; Jen CK; Chiu CH; Tzeng JC; Liaw JW
    Sensors (Basel); 2013 Jan; 13(1):975-83. PubMed ID: 23322101
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acoustic Forward Model for Guided Wave Propagation and Scattering in a Pipe Bend.
    Rasgado-Moreno CO; Rist M; Land R; Ratassepp M
    Sensors (Basel); 2022 Jan; 22(2):. PubMed ID: 35062447
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High Temperature Ultrasonic Transducers: A Review.
    Kazys R; Vaskeliene V
    Sensors (Basel); 2021 May; 21(9):. PubMed ID: 34062979
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters.
    Massaad J; van Neer PLMJ; van Willigen DM; Pertijs MAP; de Jong N; Verweij MD
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35890749
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Critical Excitation of the Fundamental Quasi-Shear Mode Wave in Waveguide Bars for Elevated Temperature Applications.
    Jia J; Liao Z; Cai X; Tu Y; Tu ST
    Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30781384
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol.
    Heifetz A; Shribak D; Huang X; Wang B; Saniie J; Young J; Bakhtiari S; Vilim RB
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Jun; 67(6):1192-1200. PubMed ID: 31995480
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of Pipe and Fluid Properties With a Matrix Array-Based Ultrasonic Clamp-On Flow Meter.
    Massaad J; van Neer PLMJ; van Willigen DM; Sabbadini A; de Jong N; Pertijs MAP; Verweij MD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jan; 69(1):309-322. PubMed ID: 34506280
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.