162 related articles for article (PubMed ID: 31027275)
1. Multifunctional Operation of an Organic Device with Three-Dimensional Architecture.
Tarabella G; Marasso SL; Bertana V; Vurro D; D'Angelo P; Iannotta S; Cocuzza M
Materials (Basel); 2019 Apr; 12(8):. PubMed ID: 31027275
[TBL] [Abstract][Full Text] [Related]
2. Enhancement-Mode PEDOT:PSS Organic Electrochemical Transistors Using Molecular De-Doping.
Keene ST; van der Pol TPA; Zakhidov D; Weijtens CHL; Janssen RAJ; Salleo A; van de Burgt Y
Adv Mater; 2020 May; 32(19):e2000270. PubMed ID: 32202010
[TBL] [Abstract][Full Text] [Related]
3. PEDOT:PSS Morphostructure and Ion-To-Electron Transduction and Amplification Mechanisms in Organic Electrochemical Transistors.
D'Angelo P; Tarabella G; Romeo A; Marasso SL; Verna A; Cocuzza M; Peruzzi C; Vurro D; Iannotta S
Materials (Basel); 2018 Dec; 12(1):. PubMed ID: 30577510
[TBL] [Abstract][Full Text] [Related]
4. Electrochemical Fabrication and Characterization of Organic Electrochemical Transistors Using poly(3,4-ethylenedioxythiophene) with Various Counterions.
Lee J; Chhatre S; Sitarik P; Wu Y; Baugh Q; Martin DC
ACS Appl Mater Interfaces; 2022 Sep; 14(37):42289-42297. PubMed ID: 36095248
[TBL] [Abstract][Full Text] [Related]
5. Oxygen Gas Sensing Using a Hydrogel-Based Organic Electrochemical Transistor for Work Safety Applications.
Decataldo F; Bonafè F; Mariani F; Serafini M; Tessarolo M; Gualandi I; Scavetta E; Fraboni B
Polymers (Basel); 2022 Mar; 14(5):. PubMed ID: 35267844
[TBL] [Abstract][Full Text] [Related]
6. Cleanroom-Free Direct Laser Micropatterning of Polymers for Organic Electrochemical Transistors in Logic Circuits and Glucose Biosensors.
Enrico A; Buchmann S; De Ferrari F; Lin Y; Wang Y; Yue W; Mårtensson G; Stemme G; Hamedi MM; Niklaus F; Herland A; Zeglio E
Adv Sci (Weinh); 2024 Jan; ():e2307042. PubMed ID: 38225700
[TBL] [Abstract][Full Text] [Related]
7. PEDOT:PSS versus Polyaniline: A Comparative Study of Conducting Polymers for Organic Electrochemical Transistors.
Kawamura R; Michinobu T
Polymers (Basel); 2023 Dec; 15(24):. PubMed ID: 38139909
[TBL] [Abstract][Full Text] [Related]
8. Concentric-Electrode Organic Electrochemical Transistors: Case Study for Selective Hydrazine Sensing.
Pecqueur S; Lenfant S; Guérin D; Alibart F; Vuillaume D
Sensors (Basel); 2017 Mar; 17(3):. PubMed ID: 28287475
[TBL] [Abstract][Full Text] [Related]
9. Surface Functionalization with (3-Glycidyloxypropyl)trimethoxysilane (GOPS) as an Alternative to Blending for Enhancing the Aqueous Stability and Electronic Performance of PEDOT:PSS Thin Films.
Osazuwa PO; Lo CY; Feng X; Nolin A; Dhong C; Kayser LV
ACS Appl Mater Interfaces; 2023 Nov; 15(47):54711-54720. PubMed ID: 37962428
[TBL] [Abstract][Full Text] [Related]
10. Water-Based PEDOT:Nafion Dispersion for Organic Bioelectronics.
Carli S; Di Lauro M; Bianchi M; Murgia M; De Salvo A; Prato M; Fadiga L; Biscarini F
ACS Appl Mater Interfaces; 2020 Jul; 12(26):29807-29817. PubMed ID: 32512998
[TBL] [Abstract][Full Text] [Related]
11. Biocompatible Ionic Liquids in High-Performing Organic Electrochemical Transistors for Ion Detection and Electrophysiological Monitoring.
Li T; Cheryl Koh JY; Moudgil A; Cao H; Wu X; Chen S; Hou K; Surendran A; Stephen M; Tang C; Wang C; Wang QJ; Tay CY; Leong WL
ACS Nano; 2022 Aug; 16(8):12049-12060. PubMed ID: 35939084
[TBL] [Abstract][Full Text] [Related]
12. Efficient Fabrication of Organic Electrochemical Transistors via Wet Chemical Processing.
Nguyen-Dang T; Chae S; Harrison K; Llanes LC; Yi A; Kim HJ; Biswas S; Visell Y; Bazan GC; Nguyen TQ
ACS Appl Mater Interfaces; 2022 Mar; 14(10):12469-12478. PubMed ID: 35230814
[TBL] [Abstract][Full Text] [Related]
13. Organic electrochemical transistors printed from degradable materials as disposable biochemical sensors.
Fumeaux N; Almeida CP; Demuru S; Briand D
Sci Rep; 2023 Jul; 13(1):11467. PubMed ID: 37454190
[TBL] [Abstract][Full Text] [Related]
14. PEDOT Composite with Ionic Liquid and Its Application to Deformable Electrochemical Transistors.
Lee S; Jang J; Lee S; Jung D; Shin M; Son D
Gels; 2022 Aug; 8(9):. PubMed ID: 36135246
[TBL] [Abstract][Full Text] [Related]
15. Characterization of Screen-Printed Organic Electrochemical Transistors to Detect Cations of Different Sizes.
Contat-Rodrigo L; Pérez-Fuster C; Lidón-Roger JV; Bonfiglio A; García-Breijo E
Sensors (Basel); 2016 Sep; 16(10):. PubMed ID: 27690032
[TBL] [Abstract][Full Text] [Related]
16. Crown ether enabled enhancement of ionic-electronic properties of PEDOT:PSS.
Stephen M; Wu X; Li T; Salim T; Hou K; Chen S; Leong WL
Mater Horiz; 2022 Aug; 9(9):2408-2415. PubMed ID: 35801931
[TBL] [Abstract][Full Text] [Related]
17. Organic Electrochemical Transistors/SERS-Active Hybrid Biosensors Featuring Gold Nanoparticles Immobilized on Thiol-Functionalized PEDOT Films.
Chou JA; Chung CL; Ho PC; Luo CH; Tsai YH; Wu CK; Kuo CW; Hsiao YS; Yu HH; Chen P
Front Chem; 2019; 7():281. PubMed ID: 31106195
[TBL] [Abstract][Full Text] [Related]
18. Realizing Ultrahigh Transconductance in Organic Electrochemical Transistor by Co-Doping PEDOT:PSS with Ionic Liquid and Dodecylbenzenesulfonate.
Wang L; Sun Q; Zhang L; Wang J; Ren G; Yu L; Wang K; Zhu Y; Lu G; Yu HD
Macromol Rapid Commun; 2022 Sep; 43(17):e2200212. PubMed ID: 35318764
[TBL] [Abstract][Full Text] [Related]
19. Fabrication and Characterization of Humidity Sensors Based on Graphene Oxide-PEDOT:PSS Composites on a Flexible Substrate.
Romero FJ; Rivadeneyra A; Becherer M; Morales DP; Rodríguez N
Micromachines (Basel); 2020 Jan; 11(2):. PubMed ID: 32013153
[TBL] [Abstract][Full Text] [Related]
20. Rapid prototyping of 3D Organic Electrochemical Transistors by composite photocurable resin.
Bertana V; Scordo G; Parmeggiani M; Scaltrito L; Ferrero S; Gomez MG; Cocuzza M; Vurro D; D'Angelo P; Iannotta S; Pirri CF; Marasso SL
Sci Rep; 2020 Aug; 10(1):13335. PubMed ID: 32770035
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]