These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 31034638)

  • 41. [Metabolic monitoring: can monitoring of brain tissue oxygen partial pressure replace measurement of jugular venous oxymetry?].
    Meixensberger J; Dings J; Jäger A; BaunachS ; Roosen K
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1999 Sep; 34 Suppl 1():S48-53. PubMed ID: 10542910
    [No Abstract]   [Full Text] [Related]  

  • 42. Implantable microchip containing oxygen-sensing paramagnetic crystals for long-term, repeated, and multisite in vivo oximetry.
    Kmiec MM; Tse D; Mast JM; Ahmad R; Kuppusamy P
    Biomed Microdevices; 2019 Jul; 21(3):71. PubMed ID: 31286244
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Detection of free radicals in reperfused dog skin flaps using electron paramagnetic resonance spectroscopy: a pilot study.
    Miller CW; Chen G; Janzen EG
    Microsurgery; 1999; 19(4):171-5. PubMed ID: 10336245
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Continuous free-flap monitoring with tissue-oxygen measurements: experiences of the last years].
    Kamolz LP; Schrögendorfer KF; Giovanoli P; Koller R; Frey M
    Handchir Mikrochir Plast Chir; 2002 May; 34(3):195-200. PubMed ID: 12203156
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The transcutaneous oxygen challenge test: a noninvasive method for detecting low cardiac output in septic patients.
    He HW; Liu DW; Long Y; Wang XT; Chai WZ; Zhou X
    Shock; 2012 Feb; 37(2):152-5. PubMed ID: 22089202
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Pre-clinical evaluation of OxyChip for long-term EPR oximetry.
    Hou H; Khan N; Gohain S; Kuppusamy ML; Kuppusamy P
    Biomed Microdevices; 2018 Mar; 20(2):29. PubMed ID: 29549438
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A comparative evaluation of EPR and OxyLite oximetry using a random sampling of pO(2) in a murine tumor.
    Vikram DS; Bratasz A; Ahmad R; Kuppusamy P
    Radiat Res; 2007 Sep; 168(3):308-15. PubMed ID: 17705635
    [TBL] [Abstract][Full Text] [Related]  

  • 48. EPR oximetry in the beating heart: myocardial oxygen consumption rate as an index of postischemic recovery.
    Ilangovan G; Liebgott T; Kutala VK; Petryakov S; Zweier JL; Kuppusamy P
    Magn Reson Med; 2004 Apr; 51(4):835-42. PubMed ID: 15065258
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Dynamic monitoring of localized tumor oxygenation changes using RF pulsed electron paramagnetic resonance in conscious mice.
    Matsumoto S; Espey MG; Utsumi H; Devasahayam N; Matsumoto K; Matsumoto A; Hirata H; Wink DA; Kuppusamy P; Subramanian S; Mitchell JB; Krishna MC
    Magn Reson Med; 2008 Mar; 59(3):619-25. PubMed ID: 18224698
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Application of in vivo EPR in brain research: monitoring tissue oxygenation, blood flow, and oxidative stress.
    Liu S; Timmins GS; Shi H; Gasparovic CM; Liu KJ
    NMR Biomed; 2004 Aug; 17(5):327-34. PubMed ID: 15366032
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A molecular paramagnetic spin-doped biopolymeric oxygen sensor.
    Meenakshisundaram G; Eteshola E; Blank A; Lee SC; Kuppusamy P
    Biosens Bioelectron; 2010 Jun; 25(10):2283-9. PubMed ID: 20371170
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Clinical hyperbaric oxygen therapy, wound perfusion, and transcutaneous oximetry.
    Niinikoski JH
    World J Surg; 2004 Mar; 28(3):307-11. PubMed ID: 14961187
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Oxygen-Sensing Paramagnetic Probes for Clinical Oximetry.
    Kmiec MM; Tse D; Kuppusamy P
    Adv Exp Med Biol; 2021; 1269():259-263. PubMed ID: 33966227
    [TBL] [Abstract][Full Text] [Related]  

  • 54. In vivo colocalization of 2-nitroimidazole EF5 fluorescence intensity and electron paramagnetic resonance oximetry in mouse tumors.
    Mahy P; De Bast M; Gallez B; Gueulette J; Koch CJ; Scalliet P; Grégoire V
    Radiother Oncol; 2003 Apr; 67(1):53-61. PubMed ID: 12758240
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Cerebral oxygenation of the cortex and striatum following normobaric hyperoxia and mild hypoxia in rats by EPR oximetry using multi-probe implantable resonators.
    Hou H; Li H; Dong R; Mupparaju S; Khan N; Swartz H
    Adv Exp Med Biol; 2011; 701():61-7. PubMed ID: 21445770
    [TBL] [Abstract][Full Text] [Related]  

  • 56. High spatial resolution multi-site EPR oximetry. The use of convolution-based fitting method.
    Grinberg OY; Smirnov AI; Swartz HM
    J Magn Reson; 2001 Oct; 152(2):247-58. PubMed ID: 11567578
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Intracellular hypoxia of tumor tissue estimated by noninvasive electron paramagnetic resonance oximetry technique using paramagnetic probes.
    Matsumoto A; Matsumoto K; Matsumoto S; Hyodo F; Sowers AL; Koscielniak JW; Devasahayam N; Subramanian S; Mitchell JB; Krishna MC
    Biol Pharm Bull; 2011; 34(1):142-5. PubMed ID: 21212532
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reproducibility of parameters of postocclusive reactive hyperemia measured by near infrared spectroscopy and transcutaneous oximetry.
    Kragelj R; Jarm T; Miklavcic D
    Ann Biomed Eng; 2000 Feb; 28(2):168-73. PubMed ID: 10710188
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry.
    Gallez B; Jordan BF; Baudelet C
    Magn Reson Med; 1999 Jul; 42(1):193-6. PubMed ID: 10398966
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Advances in probes and methods for clinical EPR oximetry.
    Swartz HM; Hou H; Khan N; Jarvis LA; Chen EY; Williams BB; Kuppusamy P
    Adv Exp Med Biol; 2014; 812():73-79. PubMed ID: 24729217
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.