438 related articles for article (PubMed ID: 31038753)
1. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD.
May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R
Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753
[TBL] [Abstract][Full Text] [Related]
2. The Effect of Inflow Cannula Length on the Intraventricular Flow Field: An In Vitro Flow Visualization Study Using the Evaheart Left Ventricular Assist Device.
May-Newman K; Moon J; Ramesh V; Montes R; Campos J; Herold B; Isingoma P; Motomura T; Benkowski R
ASAIO J; 2017; 63(5):592-603. PubMed ID: 28328554
[TBL] [Abstract][Full Text] [Related]
3. The Effect of Inflow Cannula Angle on the Intraventricular Flow Field of the Left Ventricular Assist Device-Assisted Heart: An In Vitro Flow Visualization Study.
May-Newman K; Marquez-Maya N; Montes R; Salim S
ASAIO J; 2019 Feb; 65(2):139-147. PubMed ID: 29613888
[TBL] [Abstract][Full Text] [Related]
4. Intraventricular flow patterns and stasis in the LVAD-assisted heart.
Wong K; Samaroo G; Ling I; Dembitsky W; Adamson R; del Álamo JC; May-Newman K
J Biomech; 2014 Apr; 47(6):1485-94. PubMed ID: 24612721
[TBL] [Abstract][Full Text] [Related]
5. The influence of left ventricular assist device inflow cannula position on thrombosis risk.
Ghodrati M; Maurer A; Schlöglhofer T; Khienwad T; Zimpfer D; Beitzke D; Zonta F; Moscato F; Schima H; Aigner P
Artif Organs; 2020 Sep; 44(9):939-946. PubMed ID: 32302423
[TBL] [Abstract][Full Text] [Related]
6. Left Ventricular Flow Dynamics with the HeartMate3 Left Ventricular Assist Device: Effect of Inflow Cannula Position and Speed Modulation.
Ortiz S; Vu V; Montes R; May-Newman K
ASAIO J; 2021 Dec; 67(12):1301-1311. PubMed ID: 34261878
[TBL] [Abstract][Full Text] [Related]
7. Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk.
Chivukula VK; Beckman JA; Li S; Masri SC; Levy WC; Lin S; Cheng RK; Farris SD; Wood G; Dardas TF; Kirkpatrick JN; Koomalsingh K; Zimpfer D; Mackensen GB; Chassagne F; Mahr C; Aliseda A
ASAIO J; 2020 Jul; 66(7):766-773. PubMed ID: 31453832
[TBL] [Abstract][Full Text] [Related]
8. Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk.
Chivukula VK; Beckman JA; Prisco AR; Dardas T; Lin S; Smith JW; Mokadam NA; Aliseda A; Mahr C
Circ Heart Fail; 2018 Apr; 11(4):e004325. PubMed ID: 29666072
[TBL] [Abstract][Full Text] [Related]
9. Proposing a novel technique to exclude the left ventricle with an assist device: insights from 4-dimensional flow magnetic resonance imaging.
Klotz S; Meyer-Saraei R; Frydrychowicz A; Scharfschwerdt M; Putman LM; Halder S; Sievers HH
Eur J Cardiothorac Surg; 2016 Sep; 50(3):439-45. PubMed ID: 27107046
[TBL] [Abstract][Full Text] [Related]
10. A Computational Investigation of the Effects of Temporal Synchronization of Left Ventricular Assist Device Speed Modulation with the Cardiac Cycle on Intraventricular Hemodynamics.
Straccia A; Chassagne F; Barbour MC; Beckman J; Li S; Mahr C; Aliseda A
Ann Biomed Eng; 2024 Jun; 52(6):1763-1778. PubMed ID: 38517620
[TBL] [Abstract][Full Text] [Related]
11. Numerical study of the effect of LVAD inflow cannula positioning on thrombosis risk.
He G; Han L; Zhang J; Shah A; Kaczorowski DJ; Griffith BP; Wu Z
Comput Methods Biomech Biomed Engin; 2022 Jun; 25(8):852-860. PubMed ID: 34592878
[TBL] [Abstract][Full Text] [Related]
12. Virtual Fitting and Hemodynamic Simulation of the EVAHEART 2 Left Ventricular Assist Device and Double-Cuff Tipless Inflow Cannula.
Sonntag SJ; Lipinski E; Neidlin M; Hugenroth K; Benkowski R; Motomura T; Kaufmann TAS
ASAIO J; 2019; 65(7):698-706. PubMed ID: 30134259
[TBL] [Abstract][Full Text] [Related]
13. Ventricular flow dynamics with varying LVAD inflow cannula lengths: In-silico evaluation in a multiscale model.
Liao S; Neidlin M; Li Z; Simpson B; Gregory SD
J Biomech; 2018 Apr; 72():106-115. PubMed ID: 29567308
[TBL] [Abstract][Full Text] [Related]
14. Analysis of flow within a left ventricle model fully assisted with continuous flow through the aortic valve.
Yano T; Funayama M; Sudo S; Mitamura Y
Artif Organs; 2012 Aug; 36(8):714-23. PubMed ID: 22882441
[TBL] [Abstract][Full Text] [Related]
15. Numerical prediction of thrombus risk in an anatomically dilated left ventricle: the effect of inflow cannula designs.
Liao S; Simpson B; Neidlin M; Kaufmann TA; Li Z; Woodruff MA; Gregory SD
Biomed Eng Online; 2016 Dec; 15(Suppl 2):136. PubMed ID: 28155674
[TBL] [Abstract][Full Text] [Related]
16. Surgical Techniques for Implanting the EVAHEART 2 Double Cuff Tipless Inflow Cannula.
Motomura T; Kelly B
ASAIO J; 2019; 65(8):e86-e89. PubMed ID: 30394886
[TBL] [Abstract][Full Text] [Related]
17. In Vitro Investigation of the Effect of Left Ventricular Assist Device Speed and Pulsatility Mode on Intraventricular Hemodynamics.
Chassagne F; Miramontes M; Chivukula VK; Li S; Beckman JA; Mahr C; Aliseda A
Ann Biomed Eng; 2021 May; 49(5):1318-1332. PubMed ID: 33128182
[TBL] [Abstract][Full Text] [Related]
18. In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.
Hanke JS; Krabatsch T; Rojas SV; Deniz E; Ismail I; Martens A; Shrestha M; Haverich A; Netuka I; Schmitto JD
Artif Organs; 2017 Mar; 41(3):272-275. PubMed ID: 27087560
[TBL] [Abstract][Full Text] [Related]
19. Potential of the EVAHEART 2 Double-Cuff Tipless Inflow Cannula for Prevention of Thromboembolic Events.
Ushijima T; Tanoue Y; Sonoda H; Kan-O M; Oda S; Kimura S; Hashimoto T; Fujino T; Shiose A
ASAIO J; 2022 Oct; 68(10):e168-e171. PubMed ID: 35239535
[TBL] [Abstract][Full Text] [Related]
20. Thrombus on the inflow cannula of the HeartWare HVAD: an update.
Glass CH; Christakis A; Fishbein GA; Watkins JC; Strickland KC; Mitchell RN; Padera RF
Cardiovasc Pathol; 2019; 38():14-20. PubMed ID: 30399526
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]