These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

31 related articles for article (PubMed ID: 31045444)

  • 1. Numerical simulation of flow-diverting stent: comparison between branches in bifurcation brain aneurysm.
    Boite Y; Suaiden Klein T; de Andrade Medronho R; Wajnberg E
    Biomech Model Mechanobiol; 2023 Dec; 22(6):1801-1814. PubMed ID: 37335373
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative analysis of hemodynamic changes induced by the discrepancy between the sizes of the flow diverter and parent artery.
    Kim S; Yang H; Oh JH; Kim YB
    Sci Rep; 2024 May; 14(1):10653. PubMed ID: 38724557
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design space exploration of flow diverter hydraulic resistance parameters in sidewall intracranial aneurysms.
    Sándor L; Paál G
    Comput Methods Biomech Biomed Engin; 2024 Jun; 27(8):931-942. PubMed ID: 37231591
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow diverters treatment planning of small- and medium-sized intracranial saccular aneurysms on the internal carotid artery via constraint-based virtual deployment.
    Liu Z; Zhang M; Wang C; Wang Z; Liao X; Ou C; Si W
    Int J Comput Assist Radiol Surg; 2024 Jun; 19(6):1175-1183. PubMed ID: 38619792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Towards Prediction of Blood Flow in Coiled Aneurysms Before Treatment: A Porous Media Approach.
    Romero Bhathal J; Marsh L; Levitt MR; Geindreau C; Aliseda A
    Ann Biomed Eng; 2023 Dec; 51(12):2785-2801. PubMed ID: 37598136
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessing a heterogeneous model for accounting for endovascular devices in hemodynamic simulations of cerebral aneurysms.
    Bérod A; Mut F; Cebral J; Mendez S; Chnafa C; Nicoud F
    Int J Numer Method Biomed Eng; 2023 Nov; 39(11):e3762. PubMed ID: 37515447
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Flow Reduction Efficacy of Nominal and Oversized Flow Diverters Using a Novel Measurement-assisted in Silico Method.
    Csippa B; Sándor L; Závodszky G; Szikora I; Paál G
    Clin Neuroradiol; 2024 Apr; ():. PubMed ID: 38652163
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational fluid dynamics simulation of hemodynamic changes in a hemodialysis patient with central venous stenosis treated with stent.
    Teng B; Fu Q; Wang Z
    Semin Dial; 2023; 36(5):357. PubMed ID: 37548053
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cerebral aneurysm flow diverter modeled as a thin inhomogeneous porous medium in hemodynamic simulations.
    Abdehkakha A; Hammond AL; Patel TR; Siddiqui AH; Dargush GF; Meng H
    Comput Biol Med; 2021 Dec; 139():104988. PubMed ID: 34717230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic impact of cerebral aneurysm endovascular treatment devices: coils and flow diverters.
    Goubergrits L; Schaller J; Kertzscher U; Woelken T; Ringelstein M; Spuler A
    Expert Rev Med Devices; 2014 Jul; 11(4):361-73. PubMed ID: 24918904
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A review on the reliability of hemodynamic modeling in intracranial aneurysms: why computational fluid dynamics alone cannot solve the equation.
    Berg P; Saalfeld S; Voß S; Beuing O; Janiga G
    Neurosurg Focus; 2019 Jul; 47(1):E15. PubMed ID: 31261119
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory.
    Yadollahi-Farsani H; Scougal E; Herrmann M; Wei W; Frakes D; Chong B
    Comput Methods Biomech Biomed Engin; 2019 Aug; 22(11):961-971. PubMed ID: 31045444
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.
    Xiang J; Damiano RJ; Lin N; Snyder KV; Siddiqui AH; Levy EI; Meng H
    J Neurosurg; 2015 Oct; 123(4):832-40. PubMed ID: 26090829
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effects of flow diverter with low porosity on cerebral aneurysms: a numerical stimulative study].
    Huang QH; Yang PF; Zhang X; Shi Y; Shao XM; Liu JM
    Zhonghua Yi Xue Za Zhi; 2010 Apr; 90(15):1024-7. PubMed ID: 20646519
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A pilot validation of CFD model results against PIV observations of haemodynamics in intracranial aneurysms treated with flow-diverting stents.
    Li Y; Verrelli DI; Yang W; Qian Y; Chong W
    J Biomech; 2020 Feb; 100():109590. PubMed ID: 31902608
    [TBL] [Abstract][Full Text] [Related]  

  • 16.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 17.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 18.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 2.