These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
546 related articles for article (PubMed ID: 3104693)
1. Blood conservation for myocardial revascularization. Is it cost effective? Breyer RH; Engelman RM; Rousou JA; Lemeshow S J Thorac Cardiovasc Surg; 1987 Apr; 93(4):512-22. PubMed ID: 3104693 [TBL] [Abstract][Full Text] [Related]
2. Autotransfusion utilization in abdominal trauma. Smith LA; Barker DE; Burns RP Am Surg; 1997 Jan; 63(1):47-9. PubMed ID: 8985070 [TBL] [Abstract][Full Text] [Related]
3. Effects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial. Niranjan G; Asimakopoulos G; Karagounis A; Cockerill G; Thompson M; Chandrasekaran V Eur J Cardiothorac Surg; 2006 Aug; 30(2):271-7. PubMed ID: 16829083 [TBL] [Abstract][Full Text] [Related]
4. Cost effectiveness of intraoperative autotransfusion in total hip arthroplasty surgery. Guerra JJ; Cuckler JM Clin Orthop Relat Res; 1995 Jun; (315):212-22. PubMed ID: 7634670 [TBL] [Abstract][Full Text] [Related]
5. [Cost-effectiveness analysis of an autotransfusion program in primary knee and hip replacement surgery]. Díaz-Espallardo C; Moral-García V Rev Esp Anestesiol Reanim; 1999 Nov; 46(9):396-403. PubMed ID: 10613077 [TBL] [Abstract][Full Text] [Related]
6. [Intraoperative autotransfusion. Reinfusion of erythrocytes in total hip arthroplasty reduces the need for blood from banks]. Ernst C; Röck ND; Ahlquist SE; Frandsen PA Ugeskr Laeger; 1993 Dec; 155(49):4004-7. PubMed ID: 8273215 [TBL] [Abstract][Full Text] [Related]
7. Intraoperative autotransfusion reduces blood loss after cardiopulmonary bypass. Kochamba GS; Pfeffer TA; Sintek CF; Khonsari S Ann Thorac Surg; 1996 Mar; 61(3):900-3. PubMed ID: 8619714 [TBL] [Abstract][Full Text] [Related]
8. [Use of Cell Saver 4 in traumatology. Apropos of 9 cases]. Cantais R; Coquelin G; Petit D; Stephanazi J; Quinot JF Cah Anesthesiol; 1992; 40(4):289-91. PubMed ID: 1477749 [TBL] [Abstract][Full Text] [Related]
9. Open heart operations without transfusion using a multimodality blood conservation strategy in 50 Jehovah's Witness patients: implications for a "bloodless" surgical technique. Rosengart TK; Helm RE; DeBois WJ; Garcia N; Krieger KH; Isom OW J Am Coll Surg; 1997 Jun; 184(6):618-29. PubMed ID: 9179119 [TBL] [Abstract][Full Text] [Related]
10. [Reduction of the amount of perioperative blood transfusion by autotransfusion techniques in valvular heart surgery]. Nishihama M; Takigawa A; Soga K; Hirose Y Masui; 1993 Mar; 42(3):406-11. PubMed ID: 8468785 [TBL] [Abstract][Full Text] [Related]
11. Intraoperative autologous blood collection and autotransfusion in the surgical management of early cancers of the uterine cervix. Connor JP; Morris PC; Alagoz T; Anderson B; Bottles K; Buller RE Obstet Gynecol; 1995 Sep; 86(3):373-8. PubMed ID: 7651645 [TBL] [Abstract][Full Text] [Related]
12. Autotransfusion of shed mediastinal blood after cardiac surgery: a prospective study. Schaff HV; Hauer JM; Bell WR; Gardner TJ; Donahoo JS; Gott VL; Brawley RK J Thorac Cardiovasc Surg; 1978 Apr; 75(4):632-41. PubMed ID: 642556 [TBL] [Abstract][Full Text] [Related]
13. Reduction of blood utilization during myocardial revascularization. Dietrich W; Barankay A; Dilthey G; Mitto HP; Richter JA J Thorac Cardiovasc Surg; 1989 Feb; 97(2):213-9. PubMed ID: 2783753 [TBL] [Abstract][Full Text] [Related]
14. Comparison of the effects of a cell saver and low-dose aprotinin on blood loss and homologous blood usage in patients undergoing valve surgery. Tempe DK; Banerjee A; Virmani S; Mehta N; Panwar S; Tomar AS; Ghambeer DK; Nigam M J Cardiothorac Vasc Anesth; 2001 Jun; 15(3):326-30. PubMed ID: 11426363 [TBL] [Abstract][Full Text] [Related]
15. [Haptoglobin determination in the serum of patients following intraoperative autotransfusion using the Haemonetics Cell Saver III. Studies on the loading of patients with free hemoglobin in retransfused erythrocyte concentrate]. Henn A; Hoffmann R; Müller HA Anaesthesist; 1988 Dec; 37(12):741-5. PubMed ID: 3218723 [TBL] [Abstract][Full Text] [Related]
16. [Postoperative autologous retransfusion of collected shed blood after total knee arthroplasty with the cell saver]. Handel M; Boluki D; Loibl O; Schaumburger J; Kalteis T; Matussek J; Grifka J Z Orthop Ihre Grenzgeb; 2006; 144(1):97-101. PubMed ID: 16498568 [TBL] [Abstract][Full Text] [Related]
17. [Systematic peroperative use of an autotransfusion system in heart surgery. A prospective and comparative study in 283 patients]. Nataf P; Jault F; Vaissier E; Levasseur JP; Pétrie J; Simoneau F; Fontanel M; Léger P; Fournel JJ; Cabrol C Arch Mal Coeur Vaiss; 1989 Nov; 82(11):1869-73. PubMed ID: 2514639 [TBL] [Abstract][Full Text] [Related]
18. Efficacy of intraoperative cell saver in decreasing postoperative blood transfusions in instrumented posterior lumbar fusion patients. Gause PR; Siska PA; Westrick ER; Zavatsky J; Irrgang JJ; Kang JD Spine (Phila Pa 1976); 2008 Mar; 33(5):571-5. PubMed ID: 18317204 [TBL] [Abstract][Full Text] [Related]
19. Autotransfusion in revision total hip arthroplasties using uncemented prostheses. Law JK; Wiedel JD Clin Orthop Relat Res; 1989 Aug; (245):145-9. PubMed ID: 2502340 [TBL] [Abstract][Full Text] [Related]