These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 31047059)

  • 21. A Clinico-pathologic Study of Oxidized Cellulose as Topical Hemostatic Agent in Neurosurgery.
    Gazzeri R; Neroni M; Pischedda M; Martin M; Galarza M; Campagna D; Giordano M
    Surg Technol Int; 2015 May; 26():376-81. PubMed ID: 26055035
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Oxidised regenerated cellulose as a cause of paraplegia after thoracotomy: case report and review of the literature.
    Dogan S; Kocaeli H; Doygun M
    Spinal Cord; 2005 Jul; 43(7):445-7. PubMed ID: 15897919
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bleeding from lumbar ventral epidural venous plexus managed with hemostatic agent from oxidized non-regenerated cellulose.
    Hart R
    Rozhl Chir; 2019; 98(6):245-247. PubMed ID: 31331180
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Oxidized Regenerated Cellulose during Laparoscopic Cholecystectomy Increases the Risk of Rehospitalization.
    Arisheh MA; Venturero M; Froom P
    Am Surg; 2020 Apr; 86(4):386-388. PubMed ID: 32391764
    [No Abstract]   [Full Text] [Related]  

  • 25. Use of oxidized regenerated cellulose to stop bleeding after a facelift procedure.
    Bassetto F; Vindigni V; Scarpa C; Botti C; Botti G
    Aesthetic Plast Surg; 2008 Sep; 32(5):807-9. PubMed ID: 18592302
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Allergic contact dermatitis to regenerated oxidized cellulose contained in a matrix employed for wound therapy.
    Foti C; Bonamonte D; Conserva A; Angelini G
    Contact Dermatitis; 2007 Jul; 57(1):47-8. PubMed ID: 17577358
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An alternative dressing material for the split-thickness skin graft donor site: oxidized regenerated cellulose.
    Uysal AC; Alagoz MS; Orbay H; Sensoz O
    Ann Plast Surg; 2006 Jul; 57(1):60-4. PubMed ID: 16799310
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Histiocytic reaction in pelvic peritoneum associated with oxidized regenerated cellulose.
    Kershisnik MM; Ro JY; Cannon GH; Ordonez NG; Ayala AG; Silva EG
    Am J Clin Pathol; 1995 Jan; 103(1):27-31. PubMed ID: 7817938
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Hemostatic effects of oxidized cellulose].
    Kollár P; Suchý P; Muselík J; Bajerová M; Havelka P; Sopuch T
    Ceska Slov Farm; 2008 Jan; 57(1):11-6. PubMed ID: 18383918
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A randomized clinical trial of oxidized regenerated cellulose adhesion barrier (Interceed, TC7) alone or in combination with heparin.
    Reid RL; Hahn PM; Spence JE; Tulandi T; Yuzpe AA; Wiseman DM
    Fertil Steril; 1997 Jan; 67(1):23-9. PubMed ID: 8986678
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Postoperative paraplegia secondary to the use of oxidized cellulose (Surgicel).
    Henry MC; Tashjian DB; Kasowski H; Duncan C; Moss RL
    J Pediatr Surg; 2005 Apr; 40(4):E9-11. PubMed ID: 15852266
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Peritoneal histiocytic reaction associated with oxidised regenerated cellulose, a form of mucicarminophilic histiocytosis.
    Tang KW; Lamaro V; Jaworski R
    Pathology; 2009; 41(6):598-600. PubMed ID: 19900116
    [No Abstract]   [Full Text] [Related]  

  • 33. Oxidized cellulose mimicking a recurrent colorectal cancer: report of a case and review of the literature.
    Salmo E; Bisset R; Aldean I
    Colorectal Dis; 2010 Apr; 12(4):381-2. PubMed ID: 19220373
    [No Abstract]   [Full Text] [Related]  

  • 34. Effects of laser therapy on experimental wound healing using oxidized regenerated cellulose hemostat.
    Soares LP; Oliveira MG; Pinheiro AL; Fronza BR; Maciel ME
    Photomed Laser Surg; 2008 Feb; 26(1):10-3. PubMed ID: 18248155
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessment of the efficacy of bio-absorbable oxidized regenerated cellulose for prevention of post-operative pericardial adhesion in the rabbit model.
    Biçer M; Bayram AS; Gürbüz O; Senkaya I; Yerci O; Tok M; Anğ E; Moğol EB; Saba D
    J Int Med Res; 2008; 36(6):1311-8. PubMed ID: 19094441
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Intraspinal oxidised cellulose (Surgicel) causing delayed paraplegia after thoracotomy--a report of three cases.
    Brodbelt AR; Miles JB; Foy PM; Broome JC
    Ann R Coll Surg Engl; 2002 Mar; 84(2):97-9. PubMed ID: 11995773
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Covering the staple line with polyglycolic acid sheet versus oxidized regenerated cellulose mesh after thoracoscopic bullectomy for primary spontaneous pneumothorax.
    Ozawa Y; Sakai M; Ichimura H
    Gen Thorac Cardiovasc Surg; 2018 Jul; 66(7):419-424. PubMed ID: 29693221
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A comparison of isobutyl 2-cyanoacrylate glue, fibrin adhesive, and oxidized regenerated cellulose for control of needle hole bleeding from polytetrafluoroethylene vascular prostheses.
    Barbalinardo RJ; Citrin P; Franco CD; Hobson RW
    J Vasc Surg; 1986 Sep; 4(3):220-3. PubMed ID: 2427751
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Laboratory and clinical evaluation of a new absorbable hemostatic material prepared from oxidized regenerated cellulose.
    LEBENDIGER A; GITLITZ GF; HURWITT ES; LORD GH; HENDERSON J
    Surg Forum; 1960; 10():440-3. PubMed ID: 14415011
    [No Abstract]   [Full Text] [Related]  

  • 40. The Use of Oxidized Regenerated Cellulose for Video-Assisted Thoracic Surgery.
    Tanaka Y; Tane S; Hokka D; Ogawa H; Maniwa Y
    Ann Thorac Surg; 2016 Feb; 101(2):786-8. PubMed ID: 26777946
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.