141 related articles for article (PubMed ID: 31057348)
1. Robust Motion Regression of Resting-State Data Using a Convolutional Neural Network Model.
Yang Z; Zhuang X; Sreenivasan K; Mishra V; Cordes D;
Front Neurosci; 2019; 13():169. PubMed ID: 31057348
[TBL] [Abstract][Full Text] [Related]
2. Is fMRI "noise" really noise? Resting state nuisance regressors remove variance with network structure.
Bright MG; Murphy K
Neuroimage; 2015 Jul; 114():158-69. PubMed ID: 25862264
[TBL] [Abstract][Full Text] [Related]
3. Using Edge Voxel Information to Improve Motion Regression for rs-fMRI Connectivity Studies.
Patriat R; Molloy EK; Birn RM
Brain Connect; 2015 Nov; 5(9):582-95. PubMed ID: 26107049
[TBL] [Abstract][Full Text] [Related]
4. The nuisance of nuisance regression: spectral misspecification in a common approach to resting-state fMRI preprocessing reintroduces noise and obscures functional connectivity.
Hallquist MN; Hwang K; Luna B
Neuroimage; 2013 Nov; 82():208-25. PubMed ID: 23747457
[TBL] [Abstract][Full Text] [Related]
5. Pitfalls and Recommended Strategies and Metrics for Suppressing Motion Artifacts in Functional MRI.
Raval V; Nguyen KP; Pinho M; Dewey RB; Trivedi M; Montillo AA
Neuroinformatics; 2022 Oct; 20(4):879-896. PubMed ID: 35291020
[TBL] [Abstract][Full Text] [Related]
6. An improved model of motion-related signal changes in fMRI.
Patriat R; Reynolds RC; Birn RM
Neuroimage; 2017 Jan; 144(Pt A):74-82. PubMed ID: 27570108
[TBL] [Abstract][Full Text] [Related]
7. Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm.
Ladstein J; Evensmoen HR; Håberg AK; Kristoffersen A; Goa PE
Front Neurosci; 2016; 10():225. PubMed ID: 27375405
[TBL] [Abstract][Full Text] [Related]
8. Real-time and Recursive Estimators for Functional MRI Quality Assessment.
Davydov N; Peek L; Auer T; Prilepin E; Gninenko N; Van De Ville D; Nikonorov A; Koush Y
Neuroinformatics; 2022 Oct; 20(4):897-917. PubMed ID: 35297018
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of ICA-AROMA and alternative strategies for motion artifact removal in resting state fMRI.
Pruim RHR; Mennes M; Buitelaar JK; Beckmann CF
Neuroimage; 2015 May; 112():278-287. PubMed ID: 25770990
[TBL] [Abstract][Full Text] [Related]
10. Potential pitfalls when denoising resting state fMRI data using nuisance regression.
Bright MG; Tench CR; Murphy K
Neuroimage; 2017 Jul; 154():159-168. PubMed ID: 28025128
[TBL] [Abstract][Full Text] [Related]
11. Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal.
Shmueli K; van Gelderen P; de Zwart JA; Horovitz SG; Fukunaga M; Jansma JM; Duyn JH
Neuroimage; 2007 Nov; 38(2):306-20. PubMed ID: 17869543
[TBL] [Abstract][Full Text] [Related]
12. An evaluation of the efficacy, reliability, and sensitivity of motion correction strategies for resting-state functional MRI.
Parkes L; Fulcher B; Yücel M; Fornito A
Neuroimage; 2018 May; 171():415-436. PubMed ID: 29278773
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of nuisance removal for functional MRI of rodent brain.
Chuang KH; Lee HL; Li Z; Chang WT; Nasrallah FA; Yeow LY; Singh KKDR
Neuroimage; 2019 Mar; 188():694-709. PubMed ID: 30593905
[TBL] [Abstract][Full Text] [Related]
14. A multi-measure approach for assessing the performance of fMRI preprocessing strategies in resting-state functional connectivity.
Kassinopoulos M; Mitsis GD
Magn Reson Imaging; 2022 Jan; 85():228-250. PubMed ID: 34715292
[TBL] [Abstract][Full Text] [Related]
15. EEG-assisted retrospective motion correction for fMRI: E-REMCOR.
Zotev V; Yuan H; Phillips R; Bodurka J
Neuroimage; 2012 Nov; 63(2):698-712. PubMed ID: 22836172
[TBL] [Abstract][Full Text] [Related]
16. Evaluating denoising strategies in resting-state functional magnetic resonance in traumatic brain injury (EpiBioS4Rx).
Weiler M; Casseb RF; de Campos BM; Crone JS; Lutkenhoff ES; Vespa PM; Monti MM;
Hum Brain Mapp; 2022 Oct; 43(15):4640-4649. PubMed ID: 35723510
[TBL] [Abstract][Full Text] [Related]
17. ICA-AROMA: A robust ICA-based strategy for removing motion artifacts from fMRI data.
Pruim RHR; Mennes M; van Rooij D; Llera A; Buitelaar JK; Beckmann CF
Neuroimage; 2015 May; 112():267-277. PubMed ID: 25770991
[TBL] [Abstract][Full Text] [Related]
18. Head Motion and Correction Methods in Resting-state Functional MRI.
Goto M; Abe O; Miyati T; Yamasue H; Gomi T; Takeda T
Magn Reson Med Sci; 2016; 15(2):178-86. PubMed ID: 26701695
[TBL] [Abstract][Full Text] [Related]
19. A deep convolutional neural network for estimating hemodynamic response function with reduction of motion artifacts in fNIRS.
Kim M; Lee S; Dan I; Tak S
J Neural Eng; 2022 Feb; 19(1):. PubMed ID: 35038682
[No Abstract] [Full Text] [Related]
20. Separated Channel Attention Convolutional Neural Network (SC-CNN-Attention) to Identify ADHD in Multi-Site Rs-fMRI Dataset.
Zhang T; Li C; Li P; Peng Y; Kang X; Jiang C; Li F; Zhu X; Yao D; Biswal B; Xu P
Entropy (Basel); 2020 Aug; 22(8):. PubMed ID: 33286662
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]