BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 31064124)

  • 1. Monitoring of Epoxy-Grouted Bonding Strength Development between an Anchored Steel Bar and Concrete, Using PZT-Enabled Active Sensing.
    Jiang J; Hei C; Feng Q; Jiang J
    Sensors (Basel); 2019 May; 19(9):. PubMed ID: 31064124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Crack Detection of FRP-Reinforced Concrete Beam Using Embedded Piezoceramic Smart Aggregates.
    Jiang T; Hong Y; Zheng J; Wang L; Gu H
    Sensors (Basel); 2019 Apr; 19(9):. PubMed ID: 31035619
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-Time Monitoring of Bond Slip between GFRP Bar and Concrete Structure Using Piezoceramic Transducer-Enabled Active Sensing.
    Xu K; Ren C; Deng Q; Jin Q; Chen X
    Sensors (Basel); 2018 Aug; 18(8):. PubMed ID: 30104507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tension Monitoring of Wedge Connection Using Piezoceramic Transducers and Wavelet Packet Analysis Method.
    Zhang X; Zhang L; Liu L; Huo L
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31936421
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Health Monitoring of Bolted Spherical Joint Connection Based on Active Sensing Technique Using Piezoceramic Transducers.
    Xu J; Wang C; Li H; Zhang C; Hao J; Fan S
    Sensors (Basel); 2018 May; 18(6):. PubMed ID: 29843369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers.
    Jiang T; Kong Q; Wang W; Huo L; Song G
    Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27556470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring Fatigue Damage of Modular Bridge Expansion Joints Using Piezoceramic Transducers.
    Jiang T; Zhang Y; Wang L; Zhang L; Song G
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30445787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prestress Monitoring of a Steel Strand in an Anchorage Connection Using Piezoceramic Transducers and Time Reversal Method.
    Zhang X; Zhang L; Liu L; Huo L
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30453673
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of Axial Load on Electromechanical Impedance (EMI) of Embedded Piezoceramic Transducers in Steel Fiber Concrete.
    Wang Z; Chen D; Zheng L; Huo L; Song G
    Sensors (Basel); 2018 Jun; 18(6):. PubMed ID: 29865190
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detecting Debonding between Steel Beam and Reinforcing CFRP Plate Using Active Sensing with Removable PZT-Based Transducers.
    Jiang J; Jiang J; Deng X; Deng Z
    Sensors (Basel); 2019 Dec; 20(1):. PubMed ID: 31861669
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flexural Damage Diagnosis in Reinforced Concrete Beams Using a Wireless Admittance Monitoring System-Tests and Finite Element Analysis.
    Chalioris CE; Kytinou VK; Voutetaki ME; Karayannis CG
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33498337
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of Bonding Behavior of FRP and Steel Bars in Self-Compacting Concrete Structures Using Acoustic Emission Method.
    Di B; Wang J; Li H; Zheng J; Zheng Y; Song G
    Sensors (Basel); 2019 Jan; 19(1):. PubMed ID: 30621189
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental Study on Active Interface Debonding Detection for Rectangular Concrete-Filled Steel Tubes with Surface Wave Measurement.
    Xu B; Luan L; Chen H; Wang J; Zheng W
    Sensors (Basel); 2019 Jul; 19(15):. PubMed ID: 31344793
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Damage Detection of L-Shaped Concrete Filled Steel Tube (L-CFST) Columns under Cyclic Loading Using Embedded Piezoceramic Transducers.
    Zhang J; Li Y; Du G; Song G
    Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 29986410
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of Interfacial Debonding in a Rubber-Steel-Layered Structure Using Active Sensing Enabled by Embedded Piezoceramic Transducers.
    Feng Q; Kong Q; Jiang J; Liang Y; Song G
    Sensors (Basel); 2017 Sep; 17(9):. PubMed ID: 28862666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-Physics Mesoscale Substructure Analysis on Stress Wave Measurement within CFST-PZT Coupling Models for Interface Debonding Detection.
    Wang J; Xu B; Chen H; Ge H; Zhou T
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monitoring of Interfacial Debonding of Concrete Filled Pultrusion-GFRP Tubular Column Based on Piezoelectric Smart Aggregate and Wavelet Analysis.
    Yang W; Yang X; Li S
    Sensors (Basel); 2020 Apr; 20(7):. PubMed ID: 32290195
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Feasibility Study on Timber Moisture Monitoring Using Piezoceramic Transducer-Enabled Active Sensing.
    Zhang J; Li Y; Huang Y; Jiang J; Ho SM
    Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30223502
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interfacial damage identification of steel and concrete composite beams based on piezoceramic wave method.
    Yan S; Dai Y; Zhao P; Liu W
    J Appl Biomater Funct Mater; 2018 Jan; 16(1_suppl):70-80. PubMed ID: 29618264
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A combination of PZT and EMAT transducers for interface inspection.
    Na WB; Kundu T
    J Acoust Soc Am; 2002 May; 111(5 Pt 1):2128-39. PubMed ID: 12051433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.