BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 31069968)

  • 1. Pre- and postanalytical errors in haematology.
    De la Salle B
    Int J Lab Hematol; 2019 May; 41 Suppl 1():170-176. PubMed ID: 31069968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The NEXUS vision: an alternative to the reference value concept.
    Goldschmidt HM
    Clin Chem Lab Med; 2004; 42(7):868-73. PubMed ID: 15327025
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Verification of a quantitative method: complete blood count by flow cytometry, the HematoFlow
    Vergnolle I; Allou K; Lacombe F; Mahon FX; Vial JP
    Ann Biol Clin (Paris); 2016 Oct; 74(5):617-631. PubMed ID: 27707677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Medical errors: impact on clinical laboratories and other critical areas.
    Kalra J
    Clin Biochem; 2004 Dec; 37(12):1052-62. PubMed ID: 15589810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE).
    Lippi G; Banfi G; Church S; Cornes M; De Carli G; Grankvist K; Kristensen GB; Ibarz M; Panteghini M; Plebani M; Nybo M; Smellie S; Zaninotto M; Simundic AM;
    Clin Chem Lab Med; 2015 Feb; 53(3):357-70. PubMed ID: 25490032
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications.
    Zorbozan N; Zorbozan O
    Biochem Med (Zagreb); 2022 Oct; 32(3):030701. PubMed ID: 35966260
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Laboratory error undetectable by customary quality control/quality assurance monitors.
    Kazmierczak SC; Catrou PG
    Arch Pathol Lab Med; 1993 Jul; 117(7):714-8. PubMed ID: 8323436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Errors in a stat laboratory: types and frequencies 10 years later.
    Carraro P; Plebani M
    Clin Chem; 2007 Jul; 53(7):1338-42. PubMed ID: 17525103
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preanalytical errors in medical laboratories: a review of the available methodologies of data collection and analysis.
    West J; Atherton J; Costelloe SJ; Pourmahram G; Stretton A; Cornes M
    Ann Clin Biochem; 2017 Jan; 54(1):14-19. PubMed ID: 27614351
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Retrospective Analysis of Corrected Laboratory Results in a Large Academic Medical Center.
    Kalt DA
    Am J Clin Pathol; 2019 Jul; 152(2):200-206. PubMed ID: 30985883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of quality indicators in a laboratory supporting tertiary cancer care facilities in India.
    Kumar SA; Jayanna P; Prabhudesai S; Kumar A
    Lab Med; 2014; 45(3):272-7. PubMed ID: 25051082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An error management system in a veterinary clinical laboratory.
    Hooijberg E; Leidinger E; Freeman KP
    J Vet Diagn Invest; 2012 May; 24(3):458-68. PubMed ID: 22529112
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Nature, Causes, and Clinical Impact of Errors in the Clinical Laboratory Testing Process Leading to Diagnostic Error: A Voluntary Incident Report Analysis.
    van Moll C; Egberts T; Wagner C; Zwaan L; Ten Berg M
    J Patient Saf; 2023 Dec; 19(8):573-579. PubMed ID: 37796227
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Revisited univariate delta check method for hematologic laboratories (I)--Usefulness for detection of specimen mix-up in patients with hematologic disorders].
    Ohara T; Itoh K
    Rinsho Byori; 2002 Nov; 50(11):1072-5. PubMed ID: 12491605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reducing preanalytical laboratory sample errors through educational and technological interventions.
    Lillo R; Salinas M; Lopez-Garrigos M; Naranjo-Santana Y; Gutiérrez M; Marín MD; Miralles M; Uris J
    Clin Lab; 2012; 58(9-10):911-7. PubMed ID: 23163106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of the Pre-Analytical Phase of an ISO 15189: 2012-Certified Cytopathology Laboratory: A 5-Year Institutional Experience.
    Chandra S; Chandra H; Kusum A; Singh Gaur D
    Acta Cytol; 2019; 63(1):56-62. PubMed ID: 30566946
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Automated hematology analysers and spurious counts Part 3. Haemoglobin, red blood cells, cell count and indices, reticulocytes].
    Godon A; Genevieve F; Marteau-Tessier A; Zandecki M
    Ann Biol Clin (Paris); 2012; 70(2):155-68. PubMed ID: 22484526
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Guidance for cytological automation in hematology].
    Gruson A; Chatron P
    Ann Biol Clin (Paris); 2019 Apr; 77(2):128-129. PubMed ID: 30998193
    [No Abstract]   [Full Text] [Related]  

  • 19. The concurrence of the current postanalytical phase management with the national recommendations: a survey of the Working Group for Postanalytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine.
    Jokic A; Rimac V; Vlasic Tanaskovic J; Podolar S; Honovic L; Lenicek Krleza J
    Biochem Med (Zagreb); 2021 Oct; 31(3):030704. PubMed ID: 34658645
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sources and solutions for spurious test results in coagulation.
    Marlar RA; Rollins-Raval MA
    Int J Lab Hematol; 2019 May; 41 Suppl 1():162-169. PubMed ID: 31069971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]