These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 31071686)

  • 21. Fully automated whole-head segmentation with improved smoothness and continuity, with theory reviewed.
    Huang Y; Parra LC
    PLoS One; 2015; 10(5):e0125477. PubMed ID: 25992793
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Semi-automated generation of individual computational models of the human head and torso from MR images.
    Kalloch B; Bode J; Kozlov M; Pampel A; Hlawitschka M; Sehm B; Villringer A; Möller HE; Bazin PL
    Magn Reson Med; 2019 Mar; 81(3):2090-2105. PubMed ID: 30230021
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Using reciprocity for relating the simulation of transcranial current stimulation to the EEG forward problem.
    Wagner S; Lucka F; Vorwerk J; Herrmann CS; Nolte G; Burger M; Wolters CH
    Neuroimage; 2016 Oct; 140():163-73. PubMed ID: 27125841
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Probing EEG activity in the targeted cortex after focal transcranial electrical stimulation.
    Tashiro S; Siebner HR; Charalampaki A; Göksu C; Saturnino GB; Thielscher A; Tomasevic L
    Brain Stimul; 2020; 13(3):815-818. PubMed ID: 32289712
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Approximate average head models for EEG source imaging.
    Valdés-Hernández PA; von Ellenrieder N; Ojeda-Gonzalez A; Kochen S; Alemán-Gómez Y; Muravchik C; Valdés-Sosa PA
    J Neurosci Methods; 2009 Dec; 185(1):125-32. PubMed ID: 19747944
    [TBL] [Abstract][Full Text] [Related]  

  • 26. i-SATA: A MATLAB based toolbox to estimate current density generated by transcranial direct current stimulation in an individual brain.
    Kashyap R; Bhattacharjee S; Arumugam R; Oishi K; Desmond JE; Chen SA
    J Neural Eng; 2020 Oct; 17(5):056034. PubMed ID: 32674087
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Template MRI scans reliably approximate individual and group-level tES and TMS electric fields induced in motor and prefrontal circuits.
    Cho JY; Van Hoornweder S; Sege CT; Antonucci MU; McTeague LM; Caulfield KA
    Front Neural Circuits; 2023; 17():1214959. PubMed ID: 37736398
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Modeling transcranial electrical stimulation in the aging brain.
    Indahlastari A; Albizu A; O'Shea A; Forbes MA; Nissim NR; Kraft JN; Evangelista ND; Hausman HK; Woods AJ;
    Brain Stimul; 2020; 13(3):664-674. PubMed ID: 32289695
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The impact of large structural brain changes in chronic stroke patients on the electric field caused by transcranial brain stimulation.
    Minjoli S; Saturnino GB; Blicher JU; Stagg CJ; Siebner HR; Antunes A; Thielscher A
    Neuroimage Clin; 2017; 15():106-117. PubMed ID: 28516033
    [TBL] [Abstract][Full Text] [Related]  

  • 30. ASH: an Automatic pipeline to generate realistic and individualized chronic Stroke volume conduction Head models.
    Carla Piastra M; van der Cruijsen J; Piai V; Jeukens FEM; Manoochehri M; Schouten AC; Selles RW; Oostendorp T
    J Neural Eng; 2021 Apr; 18(4):. PubMed ID: 33735847
    [No Abstract]   [Full Text] [Related]  

  • 31. Brainstorm-DUNEuro: An integrated and user-friendly Finite Element Method for modeling electromagnetic brain activity.
    Medani T; Garcia-Prieto J; Tadel F; Antonakakis M; Erdbrügger T; Höltershinken M; Mead W; Schrader S; Joshi A; Engwer C; Wolters CH; Mosher JC; Leahy RM
    Neuroimage; 2023 Feb; 267():119851. PubMed ID: 36599389
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Planning system for the optimization of electric field delivery using implanted electrodes for brain tumor control.
    Iredale E; Voigt B; Rankin A; Kim KW; Chen JZ; Schmid S; Hebb MO; Peters TM; Wong E
    Med Phys; 2022 Sep; 49(9):6055-6067. PubMed ID: 35754362
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of deep brain structure modeling on transcranial direct current stimulation-induced electric fields: An in-silico study.
    Song CB; Lim C; Lee J; Kim D; Seo H
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38082988
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Enhanced tES and tDCS computational models by meninges emulation.
    Jiang J; Truong DQ; Esmaeilpour Z; Huang Y; Badran BW; Bikson M
    J Neural Eng; 2020 Jan; 17(1):016027. PubMed ID: 31689695
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cortical Excitability through Anodal Transcranial Direct Current Stimulation: a Computational Approach.
    Arora Y; Chowdhury SR
    J Med Syst; 2020 Jan; 44(2):48. PubMed ID: 31900599
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcranial electrical stimulation motor threshold can estimate individualized tDCS dosage from reverse-calculation electric-field modeling.
    Caulfield KA; Badran BW; DeVries WH; Summers PM; Kofmehl E; Li X; Borckardt JJ; Bikson M; George MS
    Brain Stimul; 2020; 13(4):961-969. PubMed ID: 32330607
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The FieldTrip-SimBio pipeline for EEG forward solutions.
    Vorwerk J; Oostenveld R; Piastra MC; Magyari L; Wolters CH
    Biomed Eng Online; 2018 Mar; 17(1):37. PubMed ID: 29580236
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accurate TMS Head Modeling: Interfacing SimNIBS and BEM-FMM in a MATLAB-Based Module.
    Saturnino GB; Wartman WA; Makarov SN; Thielscher A
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():5326-5329. PubMed ID: 33019186
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of electrode-electrolyte spatial mismatch on transcranial direct current stimulation: a finite element modeling study.
    Chen L; Zou X; Tang R; Ke A; He J
    J Neural Eng; 2019 Aug; 16(5):056012. PubMed ID: 31195379
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An automated method for high-definition transcranial direct current stimulation modeling.
    Huang Y; Su Y; Rorden C; Dmochowski J; Datta A; Parra LC
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():5376-9. PubMed ID: 23367144
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.