These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
273 related articles for article (PubMed ID: 31071986)
61. Adaptive reconstruction of pipe-shaped human organs from 3D ultrasonic volume. Min K; Choi YJ Comput Med Imaging Graph; 2006 Mar; 30(2):109-21. PubMed ID: 16487680 [TBL] [Abstract][Full Text] [Related]
62. High-Sensitivity Ultrasonic Guided Wave Monitoring of Pipe Defects Using Adaptive Principal Component Analysis. Ma J; Tang Z; Lv F; Yang C; Liu W; Zheng Y; Zheng Y Sensors (Basel); 2021 Oct; 21(19):. PubMed ID: 34640965 [TBL] [Abstract][Full Text] [Related]
63. Fatigue state characterisation of steel pipes using ultrasonic shear waves. Sarris G; Haslinger SG; Huthwaite P; Lowe MJS IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Dec; PP():. PubMed ID: 37015567 [TBL] [Abstract][Full Text] [Related]
64. Effect of pressurization on helical guided wave energy velocity in fluid-filled pipes. Dubuc B; Ebrahimkhanlou A; Salamone S Ultrasonics; 2017 Mar; 75():145-154. PubMed ID: 27951503 [TBL] [Abstract][Full Text] [Related]
65. Monitoring pipe wall integrity using fiber Bragg grating-based sensing of low-frequency guided ultrasonic waves. Ray P; Srinivasan B; Balasubramaniam K; Rajagopal P Ultrasonics; 2018 Nov; 90():120-124. PubMed ID: 29945093 [TBL] [Abstract][Full Text] [Related]
66. Influence of the Spatial Dimensions of Ultrasonic Transducers on the Frequency Spectrum of Guided Waves. Samaitis V; Mažeika L Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28786924 [TBL] [Abstract][Full Text] [Related]
67. Torsional wave experiments with a new magnetostrictive transducer configuration. Kim YY; Park CI; Cho SH; Han SW J Acoust Soc Am; 2005 Jun; 117(6):3459-68. PubMed ID: 16018450 [TBL] [Abstract][Full Text] [Related]
68. Semi-analytical discontinuous Galerkin finite element method for the calculation of dispersion properties of guided waves in plates. Hebaz SE; Benmeddour F; Moulin E; Assaad J J Acoust Soc Am; 2018 Jan; 143(1):460. PubMed ID: 29390733 [TBL] [Abstract][Full Text] [Related]
69. Circumferential Damage Monitoring of Steel Pipe Using a Radar Map Based on Torsional Guided Waves. Zheng Z; Zhang Z Sensors (Basel); 2023 Oct; 23(21):. PubMed ID: 37960434 [TBL] [Abstract][Full Text] [Related]
70. High-frequency lowest torsional wave mode ultrasonic inspection using a necked pipe waveguide unit. Kwon YE; Kim HW; Kim YY Ultrasonics; 2015 Sep; 62():237-43. PubMed ID: 26067927 [TBL] [Abstract][Full Text] [Related]
71. Reconstruction of Water-Filled Pipe Ultrasonic Guided Wave Signals in the Distance Domain by Orthogonal Matching Pursuit Based on Dispersion and Multi-Mode. Wang Y; Tang B; Gong R; Zhou F; Chen A Sensors (Basel); 2023 Oct; 23(21):. PubMed ID: 37960382 [TBL] [Abstract][Full Text] [Related]
72. Sensitivity analysis of ultrasonic guided waves propagating in trilayered bone models: a numerical study. Tran TNHT; Le LH; Sacchi MD; Nguyen VH Biomech Model Mechanobiol; 2018 Oct; 17(5):1269-1279. PubMed ID: 29777322 [TBL] [Abstract][Full Text] [Related]
73. Anisotropic effects on ultrasonic guided waves propagation in composite bends. Yu X; Ratassepp M; Rajagopal P; Fan Z Ultrasonics; 2016 Dec; 72():95-105. PubMed ID: 27518426 [TBL] [Abstract][Full Text] [Related]
74. Propagation of Ultrasonic Guided Waves in Composite Multi-Wire Ropes. Raisutis R; Kazys R; Mazeika L; Samaitis V; Zukauskas E Materials (Basel); 2016 Jun; 9(6):. PubMed ID: 28773574 [TBL] [Abstract][Full Text] [Related]
75. Third-order shear deformation beam model for flexural waves and free vibration of pipes. Ma WL; Li XF; Yong Lee K J Acoust Soc Am; 2020 Mar; 147(3):1634. PubMed ID: 32237869 [TBL] [Abstract][Full Text] [Related]
76. Irradiance formations of on-axis Lambertian pointlike sources in polygonal total-internal-reflection straight light pipes. Cheng YK; Wang MH; Chern JL J Opt Soc Am A Opt Image Sci Vis; 2007 Sep; 24(9):2748-57. PubMed ID: 17767244 [TBL] [Abstract][Full Text] [Related]
77. Numerical and experimental investigations on quasi-static component generation of longitudinal wave propagation in isotropic pipes. Gao M; Hu X; Ng CT; Kotousov A; Lin J Ultrasonics; 2024 Mar; 138():107237. PubMed ID: 38176288 [TBL] [Abstract][Full Text] [Related]
78. Rapid thickness measurements using guided waves from a scanning laser source. Hayashi T; Murase M; Salim MN J Acoust Soc Am; 2009 Sep; 126(3):1101-6. PubMed ID: 19739722 [TBL] [Abstract][Full Text] [Related]
79. Remote characterization of defects in plates with viscoelastic coatings using guided waves. Galán JM; Abascal R Ultrasonics; 2004 Apr; 42(1-9):877-82. PubMed ID: 15047400 [TBL] [Abstract][Full Text] [Related]
80. Increased range of ultrasonic guided wave testing of overhead transmission line cables using dispersion compensation. Legg M; Yücel MK; Kappatos V; Selcuk C; Gan TH Ultrasonics; 2015 Sep; 62():35-45. PubMed ID: 25991388 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]