BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 31075786)

  • 1. Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research.
    Kim MM; Irmen P; Shoniyozov K; Verginadis II; Cengel KA; Koumenis C; Metz JM; Dong L; Diffenderfer ES
    Phys Med Biol; 2019 Jul; 64(13):135013. PubMed ID: 31075786
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An image-guided precision proton radiation platform for preclinical in vivo research.
    Ford E; Emery R; Huff D; Narayanan M; Schwartz J; Cao N; Meyer J; Rengan R; Zeng J; Sandison G; Laramore G; Mayr N
    Phys Med Biol; 2017 Jan; 62(1):43-58. PubMed ID: 27973343
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility.
    Ciocca M; Magro G; Mastella E; Mairani A; Mirandola A; Molinelli S; Russo S; Vai A; Fiore MR; Mosci C; Valvo F; Via R; Baroni G; Orecchia R
    Med Phys; 2019 Apr; 46(4):1852-1862. PubMed ID: 30659616
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Collimator design for spatially-fractionated proton beams for radiobiology research.
    Lee E; Meyer J; Sandison G
    Phys Med Biol; 2016 Jul; 61(14):5378-89. PubMed ID: 27362834
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Beam characterization and feasibility study for a small animal irradiation platform at clinical proton therapy facilities.
    Gerlach S; Pinto M; Kurichiyanil N; Grau C; Hérault J; Hillbrand M; Poulsen PR; Safai S; Schippers JM; Schwarz M; Søndergaard CS; Tommasino F; Verroi E; Vidal M; Yohannes I; Schreiber J; Parodi K
    Phys Med Biol; 2020 Dec; 65(24):245045. PubMed ID: 33157544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2018 Jul; 45(7):3246-3257. PubMed ID: 29704440
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Multimodality Image Guided Precision Radiation Research Platform: Integrating X-ray, Bioluminescence, and Fluorescence Tomography With Radiation Therapy.
    Shi J; Xu K; Keyvanloo A; Udayakumar TS; Ahmad A; Yang F; Yang Y
    Int J Radiat Oncol Biol Phys; 2020 Nov; 108(4):1063-1072. PubMed ID: 32585336
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
    Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
    Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and validation of a synchrotron proton beam line for FLASH radiotherapy preclinical research experiments.
    Titt U; Yang M; Wang X; Iga K; Fredette N; Schueler E; Lin SH; Zhu XR; Sahoo N; Koong AC; Zhang X; Mohan R
    Med Phys; 2022 Jan; 49(1):497-509. PubMed ID: 34800037
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and verification of an external radiobiological beam port on a 16.5 MeV GE PETtrace proton cyclotron.
    Asp J; Santos AMC; Moghaddasi L; Afshar SV; Bezak E
    Med Phys; 2020 Feb; 47(2):393-403. PubMed ID: 31778235
    [TBL] [Abstract][Full Text] [Related]  

  • 11.
    Schneider M; Schilz JD; Schürer M; Gantz S; Dreyer A; Rothe G; Tillner F; Bodenstein E; Horst F; Beyreuther E
    Phys Med Biol; 2024 Apr; 69(9):. PubMed ID: 38537301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Towards a novel small animal proton irradiation platform: the SIRMIO project.
    Parodi K; Assmann W; Belka C; Bortfeldt J; Clevert DA; Dedes G; Kalunga R; Kundel S; Kurichiyanil N; Lämmer P; Lascaud J; Lauber K; Lovatti G; Meyer S; Nitta M; Pinto M; Safari MJ; Schnürle K; Schreiber J; Thirolf PG; Wieser HP; Würl M
    Acta Oncol; 2019 Oct; 58(10):1470-1475. PubMed ID: 31271091
    [No Abstract]   [Full Text] [Related]  

  • 13. A comprehensive geometric quality assurance framework for preclinical microirradiators.
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2019 Apr; 46(4):1840-1851. PubMed ID: 30656713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Development of Technology for Effective Respiratory-Gated Irradiation Using an Image-Guided Small Animal Irradiator.
    Hill MA; Thompson JM; Kavanagh A; Tullis IDC; Newman RG; Prentice J; Beech J; Gilchrist S; Smart S; Fokas E; Vojnovic B
    Radiat Res; 2017 Sep; 188(3):247-263. PubMed ID: 28715250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of different fiducial markers for image-guided radiotherapy and particle therapy.
    Habermehl D; Henkner K; Ecker S; Jäkel O; Debus J; Combs SE
    J Radiat Res; 2013 Jul; 54 Suppl 1(Suppl 1):i61-8. PubMed ID: 23824129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System.
    Patriarca A; Fouillade C; Auger M; Martin F; Pouzoulet F; Nauraye C; Heinrich S; Favaudon V; Meyroneinc S; Dendale R; Mazal A; Poortmans P; Verrelle P; De Marzi L
    Int J Radiat Oncol Biol Phys; 2018 Nov; 102(3):619-626. PubMed ID: 30017793
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A quality assurance for respiratory gated proton irradiation with range modulation wheel.
    Yasui K; Shimomura A; Toshito T; Tanaka K; Ueki K; Muramatsu R; Katsurada M; Hayashi N; Ogino H
    J Appl Clin Med Phys; 2019 Jan; 20(1):258-264. PubMed ID: 30597762
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.
    Schellhammer SM; Gantz S; Lühr A; Oborn BM; Bussmann M; Hoffmann AL
    Med Phys; 2018 Jul; 45(7):3429-3434. PubMed ID: 29763970
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system.
    Rana S; Bennouna J; Samuel EJJ; Gutierrez AN
    J Appl Clin Med Phys; 2019 Apr; 20(4):29-44. PubMed ID: 30920146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP).
    Jermoumi M; Korideck H; Bhagwat M; Zygmanski P; Makrigiogos GM; Berbeco RI; Cormack RC; Ngwa W
    Phys Med; 2015 Jul; 31(5):529-35. PubMed ID: 25964129
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.