These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 31085224)

  • 1. Left Ventricular Assist Device Outflow Graft Compression: Incidence, Clinical Associations and Potential Etiologies.
    Trankle CR; Grizzard JD; Shah KB; Rezai Gharai L; Dana F; Kang MS; Andreae AE; Desai K; Quader MA; Gertz ZM
    J Card Fail; 2019 Jul; 25(7):545-552. PubMed ID: 31085224
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An interventional approach to left ventricular assist device outflow graft obstruction.
    Gertz ZM; Trankle CR; Grizzard JD; Quader MA; Medalion B; Parris KE; Shah KB
    Catheter Cardiovasc Interv; 2021 Nov; 98(5):969-974. PubMed ID: 33586847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Incidence, clinical relevance and therapeutic options for outflow graft stenosis in patients with left ventricular assist devices.
    Dimitrov K; Kaider A; Angleitner P; Schlöglhofer T; Gross C; Beitzke D; Granegger M; Riebandt J; Wiedemann D; Sandner S; Schaefer AK; Schima H; Laufer G; Zimpfer D
    Eur J Cardiothorac Surg; 2022 Feb; 61(3):716-724. PubMed ID: 34468714
    [TBL] [Abstract][Full Text] [Related]  

  • 4. First successful percutaneous treatment of a totally occluded HeartWare outflow graft: Case report and literature review.
    Kemaloğlu C; Altekin RE; Bayezid Ö
    Anatol J Cardiol; 2018 May; 19(5):341-345. PubMed ID: 29724977
    [TBL] [Abstract][Full Text] [Related]  

  • 5. First results of HeartWare left ventricular assist device implantation with tunnelling of the outflow graft through the transverse sinus.
    Hanke JS; Rojas SV; Cvitkovic T; Wiegmann B; Horke A; Warnecke G; Haverich A; Schmitto JD
    Interact Cardiovasc Thorac Surg; 2017 Oct; 25(4):503-508. PubMed ID: 28962493
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surgical intervention for left ventricular assist device outflow graft obstruction due to external compression.
    Wang L; Rafiq M; Tweed K; Kydd A; Kaul P; Jenkins D; Tsui S; Berman M
    Multimed Man Cardiothorac Surg; 2023 Oct; 2023():. PubMed ID: 37823383
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outflow Graft Narrowing of the HeartMate 3 Left Ventricular Assist Device.
    Jain SS; Clerkin KJ; Anstey DE; Liu Q; Fried JA; Raikhelkar J; Griffin JM; Marshall D; Colombo P; Yuzefpolskaya M; Topkara V; Naka Y; Takeda K; Sayer G; Uriel N; Leb J
    Ann Thorac Surg; 2023 May; 115(5):1282-1288. PubMed ID: 34998738
    [TBL] [Abstract][Full Text] [Related]  

  • 8. From bench to bedside: Impact of left ventricular assist device outflow conduit anastomosis position on outcome.
    Tarzia V; Di Giammarco G; Bagozzi L; Bortolussi G; Maccherini M; Marinelli D; Bernazzali S; Maiani M; Gregori D; Scuri S; Tessari C; Fabozzo A; Bottio T; Livi U; Gerosa G
    Artif Organs; 2021 Mar; 45(3):236-243. PubMed ID: 32860268
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Role of computed tomography angiography for HeartMate II left ventricular assist device thrombosis.
    Yu SN; Han J; Takeda K; Ginns JN; Kurlansky PA; Garan AR; Yuzefpolskaya M; Topkara VK; Colombo PC; Naka Y; Takayama H
    Int J Artif Organs; 2018 Jun; 41(6):325-332. PubMed ID: 29562790
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Late inflow or outflow obstruction requiring surgical intervention after HeartMate 3 left ventricular assist device insertion.
    Kaku Y; Naka Y; Witer L; Topkara V; Colombo P; Sayer G; Uriel N; Takeda K
    Interact Cardiovasc Thorac Surg; 2020 Nov; 31(5):626-628. PubMed ID: 32888010
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Proximal outflow graft extrinsic compression of the Heartmate 3 centrifugal flow left ventricular assist device resulting in pump dysfunction.
    Guihaire J; Kloeckner M; Isorni MA
    J Artif Organs; 2020 Jun; 23(2):180-182. PubMed ID: 31555999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bridge to Transplantation With Long-Term Mechanical Assist Devices in Adults With Transposition of the Great Arteries.
    Michel E; Orozco Hernandez E; Enter D; Monge M; Nakano J; Rich J; Anderson A; Backer C; McCarthy P; Pham D
    Artif Organs; 2019 Jan; 43(1):90-96. PubMed ID: 30129258
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnosis of Left Ventricular Assist Device Outflow Graft Obstruction Using Intravascular Ultrasound.
    Muller Moran HR; Kass M; Ravandi A; Zieroth S; Schaffer SA; Cordova FJ; Pozeg ZI; Arora RC; Singal RK
    Circ Heart Fail; 2016 Dec; 9(12):. PubMed ID: 27864303
    [No Abstract]   [Full Text] [Related]  

  • 14. Left Ventricular Assist Device Outflow Graft Obstruction: A Complication Specific to Polytetrafluoroethylene Covering. A Word of Caution!
    Alnabelsi T; Shafii AE; Gurley JC; Dulnuan K; Harris DD; Guglin M
    ASAIO J; 2019 Aug; 65(6):e58-e62. PubMed ID: 30575627
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
    John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
    Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cerebral protection during percutaneous intervention for left ventricular assist device outflow graft obstruction.
    Joury A; Patel RAG; Wever-Pinzon J; Eiswirth C; Desai S; Bansal A; Krim SR
    Catheter Cardiovasc Interv; 2022 Aug; 100(2):266-273. PubMed ID: 35612519
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes of outflow graft stenting in HeartMate 3 left ventricular assist devices: A systematic review and individual patient data meta-analysis.
    Patil S; Ahmad D; Shah K; Vishnevsky A; Ruggiero NJ; Rajapreyar IN; Rame JE; Alvarez RJ; Rajagopal K; Entwistle JW; Massey HT; Tchantchaleishvili V
    Artif Organs; 2024 Jun; 48(6):577-585. PubMed ID: 38577853
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Survival outcomes of stenting outflow graft stenosis in continuous-flow left ventricular assist devices: a systematic review.
    Wood CT; O'Malley TJ; Maynes EJ; Vishnevsky A; Morris RJ; Samuels LE; Massey HT; Tchantchaleishvili V
    Heart Fail Rev; 2020 Nov; 25(6):985-992. PubMed ID: 31820204
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kinking of the Outflow Graft, Consequent Ventricular Tachycardia, and the Need for Reoperation in a Patient with Left Ventricular Assist Device.
    Terzic D; Nestorovic E; Putnik S; Markovic D; Ristic M
    Heart Surg Forum; 2017 Aug; 20(4):E139-E141. PubMed ID: 28846527
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contained Rupture in HeartMate II Outflow Graft Bend Relief Disconnection.
    Chua KC; Tan TE; Lim CH; Kerk KL; Sivathasan C
    Asian Cardiovasc Thorac Ann; 2016 Mar; 24(3):269-71. PubMed ID: 25348159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.