These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
231 related articles for article (PubMed ID: 31087667)
1. Dissemination of a novel organ perfusion technique: ex vivo normothermic perfusion of deceased donor kidneys. Chandak P; Phillips BL; Uwechue R; Thompson E; Bates L; Ibrahim I; Sewpaul A; Figueiredo R; Olsburgh J; Hosgood S; Nicholson ML; Wilson C; Callaghan CJ Artif Organs; 2019 Nov; 43(11):E308-E319. PubMed ID: 31087667 [TBL] [Abstract][Full Text] [Related]
2. Protocol of a randomised controlled, open-label trial of ex vivo normothermic perfusion versus static cold storage in donation after circulatory death renal transplantation. Hosgood SA; Saeb-Parsy K; Wilson C; Callaghan C; Collett D; Nicholson ML BMJ Open; 2017 Jan; 7(1):e012237. PubMed ID: 28115329 [TBL] [Abstract][Full Text] [Related]
3. Renal transplantation after ex vivo normothermic perfusion: the first clinical study. Nicholson ML; Hosgood SA Am J Transplant; 2013 May; 13(5):1246-52. PubMed ID: 23433047 [TBL] [Abstract][Full Text] [Related]
4. Successful Transplantation of Human Kidneys Deemed Untransplantable but Resuscitated by Ex Vivo Normothermic Machine Perfusion. Hosgood SA; Saeb-Parsy K; Hamed MO; Nicholson ML Am J Transplant; 2016 Nov; 16(11):3282-3285. PubMed ID: 27273794 [TBL] [Abstract][Full Text] [Related]
5. Combined Ex Vivo Hypothermic and Normothermic Perfusion for Assessment of High-risk Deceased Donor Human Kidneys for Transplantation. Kabagambe SK; Palma IP; Smolin Y; Boyer T; Palma I; Sageshima J; Troppmann C; Santhanakrishnan C; McVicar JP; Jen KY; Nuño M; Perez RV Transplantation; 2019 Feb; 103(2):392-400. PubMed ID: 29952816 [TBL] [Abstract][Full Text] [Related]
6. Normothermic machine perfusion of the kidney: better conditioning and repair? Hosgood SA; van Heurn E; Nicholson ML Transpl Int; 2015 Jun; 28(6):657-64. PubMed ID: 24629095 [TBL] [Abstract][Full Text] [Related]
7. The use of ex-vivo normothermic perfusion for the resuscitation and assessment of human kidneys discarded because of inadequate in situ perfusion. Hosgood SA; Barlow AD; Dormer J; Nicholson ML J Transl Med; 2015 Oct; 13():329. PubMed ID: 26474973 [TBL] [Abstract][Full Text] [Related]
8. Normothermic ex vivo perfusion of deceased donor kidneys and its clinical potential in kidney transplantation outcomes. Unes M; Kurashima K; Caliskan Y; Portz E; Jain A; Nazzal M Int J Artif Organs; 2023 Dec; 46(12):618-628. PubMed ID: 37897367 [TBL] [Abstract][Full Text] [Related]
9. The effects of arterial pressure during normothermic kidney perfusion. Patel M; Hosgood S; Nicholson ML J Surg Res; 2014 Oct; 191(2):463-8. PubMed ID: 24811916 [TBL] [Abstract][Full Text] [Related]
10. Ex-vivo machine perfusion for kidney preservation. Hamar M; Selzner M Curr Opin Organ Transplant; 2018 Jun; 23(3):369-374. PubMed ID: 29697462 [TBL] [Abstract][Full Text] [Related]
11. Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation. Kaths JM; Spetzler VN; Goldaracena N; Echeverri J; Louis KS; Foltys DB; Strempel M; Yip P; John R; Mucsi I; Ghanekar A; Bagli D; Robinson L; Selzner M J Vis Exp; 2015 Jul; (101):e52909. PubMed ID: 26275014 [TBL] [Abstract][Full Text] [Related]
12. Ex vivo normothermic perfusion for quality assessment of marginal donor kidney transplants. Hosgood SA; Barlow AD; Hunter JP; Nicholson ML Br J Surg; 2015 Oct; 102(11):1433-40. PubMed ID: 26313559 [TBL] [Abstract][Full Text] [Related]
13. Ex-vivo normothermic perfusion in renal transplantation: past, present and future. Yong C; Hosgood SA; Nicholson ML Curr Opin Organ Transplant; 2016 Jun; 21(3):301-7. PubMed ID: 27145197 [TBL] [Abstract][Full Text] [Related]
14. Normothermic ex vivo allograft blood perfusion in clinical heart transplantation. Koerner MM; Ghodsizad A; Schulz U; El Banayosy A; Koerfer R; Tenderich G Heart Surg Forum; 2014 Jun; 17(3):E141-5. PubMed ID: 25002389 [TBL] [Abstract][Full Text] [Related]
15. Viability assessment and utilization of declined donor kidneys with rhabdomyolysis using ex vivo normothermic perfusion without preimplantation biopsy. Pearson R; Asher J; Jackson A; Mark PB; Shumeyko V; Clancy MJ Am J Transplant; 2021 Mar; 21(3):1317-1321. PubMed ID: 33021059 [TBL] [Abstract][Full Text] [Related]
16. Safety and feasibility of 2 h of normothermic machine perfusion of donor kidneys in the Eurotransplant Senior Program. Rijkse E; de Jonge J; Kimenai HJAN; Hoogduijn MJ; de Bruin RWF; van den Hoogen MWF; IJzermans JNM; Minnee RC BJS Open; 2021 Jan; 5(1):. PubMed ID: 33609374 [TBL] [Abstract][Full Text] [Related]
17. One-year results of a prospective, randomized trial comparing two machine perfusion devices used for kidney preservation. Wszola M; Kwiatkowski A; Diuwe P; Domagała P; Górski L; Kieszek R; Berman A; Perkowska-Ptasińska A; Durlik M; Pączek L; Chmura A Transpl Int; 2013 Nov; 26(11):1088-96. PubMed ID: 24033725 [TBL] [Abstract][Full Text] [Related]
18. Outcome Improvement for Hypothermic Machine Perfusion Versus Cold Storage for Kidneys From Cardiac Death Donors. Zhong Z; Lan J; Ye S; Liu Z; Fan L; Zhang Y; Fu Z; Qiao B; Shiu-Chung Ko D; Wang Y; Ye Q Artif Organs; 2017 Jul; 41(7):647-653. PubMed ID: 28703374 [TBL] [Abstract][Full Text] [Related]
19. Effect of Hypothermic Machine Perfusion on the Preservation of Kidneys Donated After Cardiac Death: A Single-Center, Randomized, Controlled Trial. Wang W; Xie D; Hu X; Yin H; Liu H; Zhang X Artif Organs; 2017 Aug; 41(8):753-758. PubMed ID: 28176336 [TBL] [Abstract][Full Text] [Related]
20. Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death. Treckmann J; Moers C; Smits JM; Gallinat A; Maathuis MH; van Kasterop-Kutz M; Jochmans I; Homan van der Heide JJ; Squifflet JP; van Heurn E; Kirste GR; Rahmel A; Leuvenink HG; Pirenne J; Ploeg RJ; Paul A Transpl Int; 2011 Jun; 24(6):548-54. PubMed ID: 21332580 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]