These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 31093515)

  • 1. BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature newborn brain.
    Giovannella M; Contini D; Pagliazzi M; Pifferi A; Spinelli L; Erdmann R; Donat R; Rocchetti I; Rehberger M; König N; Schmitt R; Torricelli A; Durduran T; Weigel UM
    Neurophotonics; 2019 Apr; 6(2):025007. PubMed ID: 31093515
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerebral oxygenation and blood flow in normal term infants at rest measured by a hybrid near-infrared device (BabyLux).
    Andresen B; De Carli A; Fumagalli M; Giovannella M; Durduran T; Michael Weigel U; Contini D; Spinelli L; Torricelli A; Greisen G
    Pediatr Res; 2019 Oct; 86(4):515-521. PubMed ID: 31234195
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy and precision of tissue optical properties and hemodynamic parameters estimated by the BabyLux device: a hybrid time-resolved near-infrared and diffuse correlation spectroscopy neuro-monitor.
    Giovannella M; Spinelli L; Pagliazzi M; Contini D; Greisen G; Weigel UM; Torricelli A; Durduran T
    Biomed Opt Express; 2019 May; 10(5):2556-2579. PubMed ID: 31149383
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cerebral oxygenation and blood flow in term infants during postnatal transition: BabyLux project.
    De Carli A; Andresen B; Giovannella M; Durduran T; Contini D; Spinelli L; Weigel UM; Passera S; Pesenti N; Mosca F; Torricelli A; Fumagalli M; Greisen G
    Arch Dis Child Fetal Neonatal Ed; 2019 Nov; 104(6):F648-F653. PubMed ID: 31085677
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of Optical Neuromonitoring in Neonatal Encephalopathy-Current State and Recent Advances.
    Harvey-Jones K; Lange F; Tachtsidis I; Robertson NJ; Mitra S
    Front Pediatr; 2021; 9():653676. PubMed ID: 33898363
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Compact Multi-Distance DCS and Time Domain NIRS Hybrid System for Hemodynamic and Metabolic Measurements.
    Amendola C; Lacerenza M; Buttafava M; Tosi A; Spinelli L; Contini D; Torricelli A
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33525488
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cerebrovascular reactivity to carbon dioxide tension in newborns: data from combined time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy.
    Passera S; De Carli A; Fumagalli M; Contini D; Pesenti N; Amendola C; Giovannella M; Durduran T; Weigel UM; Spinelli L; Torricelli A; Greisen G
    Neurophotonics; 2023 Oct; 10(4):045003. PubMed ID: 37841558
    [TBL] [Abstract][Full Text] [Related]  

  • 8.
    Cortese L; Fernández Esteberena P; Zanoletti M; Lo Presti G; Aranda Velazquez G; Ruiz Janer S; Buttafava M; Renna M; Di Sieno L; Tosi A; Dalla Mora A; Wojtkiewicz S; Dehghani H; de Fraguier S; Nguyen-Dinh A; Rosinski B; Weigel UM; Mesquida J; Squarcia M; Hanzu FA; Contini D; Mora Porta M; Durduran T
    Physiol Meas; 2023 Dec; 44(12):. PubMed ID: 38061053
    [No Abstract]   [Full Text] [Related]  

  • 9. Simultaneous monitoring of cerebral perfusion and cytochrome c oxidase by combining broadband near-infrared spectroscopy and diffuse correlation spectroscopy.
    Rajaram A; Bale G; Kewin M; Morrison LB; Tachtsidis I; St Lawrence K; Diop M
    Biomed Opt Express; 2018 Jun; 9(6):2588-2603. PubMed ID: 30258675
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Perfusion and Metabolic Neuromonitoring during Ventricular Taps in Infants with Post-Hemorrhagic Ventricular Dilatation.
    Rajaram A; Yip LCM; Milej D; Suwalski M; Kewin M; Lo M; Carson JJL; Han V; Bhattacharya S; Diop M; de Ribaupierre S; St Lawrence K
    Brain Sci; 2020 Jul; 10(7):. PubMed ID: 32679665
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of a Time-Resolved Diffuse Optical Spectroscopy Prototype Using Low-Cost, Compact Single Photon Avalanche Detectors for Tissue Optics Applications.
    Alayed M; Palubiak DP; Deen MJ
    Sensors (Basel); 2018 Oct; 18(11):. PubMed ID: 30380688
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PV-MBLL algorithm for extraction of absolute tissue oxygenation information by diffuse optical spectroscopy.
    Bai J; Zhu Q; Liu Y; Zhou Y; Shi T; Gui Z; Shang Y
    Comput Methods Programs Biomed; 2020 Sep; 193():105456. PubMed ID: 32305645
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance Assessment of a Commercial Continuous-Wave Near-Infrared Spectroscopy Tissue Oximeter for Suitability for Use in an International, Multi-Center Clinical Trial.
    Cortese L; Zanoletti M; Karadeniz U; Pagliazzi M; Yaqub MA; Busch DR; Mesquida J; Durduran T
    Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770264
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cerebral oxygenation as measured by near-infrared spectroscopy in neonatal intensive care: correlation with arterial oxygenation.
    Hunter CL; Oei JL; Lui K; Schindler T
    Acta Paediatr; 2017 Jul; 106(7):1073-1078. PubMed ID: 28349556
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Wearable Fiber-Free Optical Sensor for Continuous Monitoring of Neonatal Cerebral Blood Flow and Oxygenation.
    Liu X; Mohtasebi M; Safavi P; Fathi F; Haratbar SR; Chen L; Chen J; Bada HS; Chen L; Abu Jawdeh EG; Yu G
    medRxiv; 2023 Sep; ():. PubMed ID: 37790418
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wearable fiber-free optical sensor for continuous monitoring of neonatal cerebral blood flow and oxygenation.
    Liu X; Mohtasebi M; Safavi P; Fathi F; Haratbar SR; Chen L; Chen J; Bada HS; Chen L; Abu Jawdeh EG; Yu G
    Pediatr Res; 2024 Mar; ():. PubMed ID: 38503982
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interferometric diffuse correlation spectroscopy improves measurements at long source-detector separation and low photon count rate.
    Robinson M; Boas D; Sakadžic S; Franceschini MA; Carp S
    J Biomed Opt; 2020 Sep; 25(9):. PubMed ID: 33000571
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantifying the cerebral metabolic rate of oxygen by combining diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy.
    Verdecchia K; Diop M; Lee TY; St Lawrence K
    J Biomed Opt; 2013 Feb; 18(2):27007. PubMed ID: 23389684
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cerebral near infrared spectroscopy oximetry in extremely preterm infants: phase II randomised clinical trial.
    Hyttel-Sorensen S; Pellicer A; Alderliesten T; Austin T; van Bel F; Benders M; Claris O; Dempsey E; Franz AR; Fumagalli M; Gluud C; Grevstad B; Hagmann C; Lemmers P; van Oeveren W; Pichler G; Plomgaard AM; Riera J; Sanchez L; Winkel P; Wolf M; Greisen G
    BMJ; 2015 Jan; 350():g7635. PubMed ID: 25569128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.
    Yu G; Durduran T; Lech G; Zhou C; Chance B; Mohler ER; Yodh AG
    J Biomed Opt; 2005; 10(2):024027. PubMed ID: 15910100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.