These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 31095474)

  • 1. Cardiac Electrical Modeling for Closed-Loop Validation of Implantable Devices.
    Ai W; Patel ND; Roop PS; Malik A; Trew ML
    IEEE Trans Biomed Eng; 2020 Feb; 67(2):536-544. PubMed ID: 31095474
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Parametric Computational Model of the Action Potential of Pacemaker Cells.
    Ai W; Patel ND; Roop PS; Malik A; Andalam S; Yip E; Allen N; Trew ML
    IEEE Trans Biomed Eng; 2018 Jan; 65(1):123-130. PubMed ID: 28436840
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closing the Loop: Validation of Implantable Cardiac Devices With Computational Heart Models.
    Ai W; Patel ND; Roop PS; Malik A; Trew ML
    IEEE J Biomed Health Inform; 2020 Jun; 24(6):1579-1588. PubMed ID: 31613786
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hybrid automata models of cardiac ventricular electrophysiology for real-time computational applications.
    Andalam S; Ramanna H; Malik A; Roop P; Patel N; Trew ML
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5595-5598. PubMed ID: 28269523
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modification of the DDD pacing mode to prevent junctional reentry tachycardia: computer modelling experiments.
    Malik M; Davies DW; Camm AJ
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1465-78. PubMed ID: 2462224
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interventional electrophysiology and its role in the treatment of cardiac arrhythmia.
    Teo WS; Kam R; Tan A
    Ann Acad Med Singap; 1998 Mar; 27(2):248-54. PubMed ID: 9663319
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A logical state model of circus movement atrial flutter role of anatomic obstacles, anisotropic conduction and slow conduction zones on induction, sustenance, and overdrive paced modulation of reentrant circuits.
    Yang H; el-Sherif N; Isber N; Restivo M
    IEEE Trans Biomed Eng; 1994 Jun; 41(6):537-48. PubMed ID: 7927373
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling cardiac pacemaker malfunctions with the Virtual Heart Model.
    Jiang Z; Mangharam R
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():263-6. PubMed ID: 22254300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computer simulation of overdrive pacing during atrioventricular reentrant tachycardia.
    Malik M; Camm AJ
    Int J Biomed Comput; 1991 Oct; 29(1):7-21. PubMed ID: 1959984
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computer modeling of cardiac rhythm disturbances and heart-pacemaker interaction.
    Malik M; Camm AJ
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):2101-9. PubMed ID: 2463595
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Responses to pacing depend on electrical and structural properties of the reentrant circuit.
    Frame LH
    J Cardiovasc Electrophysiol; 2003 Oct; 14(10):1075-6. PubMed ID: 14521660
    [No Abstract]   [Full Text] [Related]  

  • 12. Mechanisms of clinical tachycardias.
    Akhtar M; Tchou PJ; Jazayeri M
    Am J Cardiol; 1988 Jan; 61(2):9A-19A. PubMed ID: 3276129
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A model for human action potential dynamics in vivo.
    Gray RA; Franz MR
    Am J Physiol Heart Circ Physiol; 2020 Mar; 318(3):H534-H546. PubMed ID: 31951472
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of Na(+) channel and cell coupling abnormalities on vulnerability to reentry: a simulation study.
    Qu Z; Karagueuzian HS; Garfinkel A; Weiss JN
    Am J Physiol Heart Circ Physiol; 2004 Apr; 286(4):H1310-21. PubMed ID: 14630634
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Exploring reentrant arrhythmias with numerical experiments: generic properties and model complexity.
    Starmer CF
    J Cardiovasc Electrophysiol; 2009 Jun; 20(6):685-8. PubMed ID: 19220566
    [No Abstract]   [Full Text] [Related]  

  • 16. A Formal Approach for Scalable Simulation of Gastric ICC Electrophysiology.
    Wang L; Malik A; Roop PS; Cheng LK; Paskaranandavadivel N
    IEEE Trans Biomed Eng; 2019 Dec; 66(12):3320-3329. PubMed ID: 30869606
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical mapping system with real-time control capability.
    Iravanian S; Christini DJ
    Am J Physiol Heart Circ Physiol; 2007 Oct; 293(4):H2605-11. PubMed ID: 17644571
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interactions between extracellular stimuli and excitation waves in an atrial reentrant loop.
    Johnson CR; Barr RC
    J Cardiovasc Electrophysiol; 2003 Oct; 14(10):1064-74. PubMed ID: 14521659
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High resolution mapping of Koch's triangle using sixty electrodes in humans with atrioventricular junctional (AV nodal) reentrant tachycardia.
    McGuire MA; Bourke JP; Robotin MC; Johnson DC; Meldrum-Hanna W; Nunn GR; Uther JB; Ross DL
    Circulation; 1993 Nov; 88(5 Pt 1):2315-28. PubMed ID: 8222125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A computational framework for testing arrhythmia marker sensitivities to model parameters in functionally calibrated populations of atrial cells.
    Vagos MR; Arevalo H; de Oliveira BL; Sundnes J; Maleckar MM
    Chaos; 2017 Sep; 27(9):093941. PubMed ID: 28964122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.