  • 1. Solysafe Device Pushed Away by Amplatzer Septal Occluder After Closure of a Residual Atrial Septal Defect.
    Sigler M; Horke A; Paul T; Uhlemann F
    JACC Cardiovasc Interv; 2019 Jun; 12(11):e95-e96. PubMed ID: 31103536
    [No Abstract]   [Full Text] [Related]  

  • 2. AMPLATZER Septal Occluder failure resulting in paradoxical cerebral embolism.
    Fernando RR; Koranne KP; Barker CM
    Tex Heart Inst J; 2012; 39(5):647-52. PubMed ID: 23109759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter retrieval of embolized AMPLATZER Septal Occluder.
    Goel PK; Kapoor A; Batra A; Khanna R
    Tex Heart Inst J; 2012; 39(5):653-6. PubMed ID: 23109760
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Novel Percutaneous Technique Using Lasso Catheters for Retrieval of an Embolized Amplatzer Atrial Septal Occluder Device.
    Padala SK; Saini A; Gertz ZM; Morano GS; Ellenbogen KA; Koneru JN
    JACC Cardiovasc Interv; 2017 Feb; 10(3):e25-e26. PubMed ID: 28109875
    [No Abstract]   [Full Text] [Related]  

  • 5. Very late erosion of Amplatzer septal occluder device presenting as pericardial pain and effusion 8 years after placement.
    Roberts WT; Parmar J; Rajathurai T
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E592-4. PubMed ID: 23172721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept.
    Georgiev S; Tanase D; Genz T; Ewert P; Naumann S; Pozza RD; Eicken A
    Cardiol Young; 2018 Jul; 28(7):955-960. PubMed ID: 29779498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter closure of atrial septal defect with the Figulla(®) ASD Occluder: a comparative study with the Amplatzer(®) Septal Occluder.
    Godart F; Houeijeh A; Recher M; Francart C; Polge AS; Richardson M; Cajot MA; Duhamel A
    Arch Cardiovasc Dis; 2015 Jan; 108(1):57-63. PubMed ID: 25453168
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tulip malformation of the left atrial disc in the Lifetech Cera ASD device: a novel complication of percutaneous ASD closure.
    Hayes N; Rosenthal E
    Catheter Cardiovasc Interv; 2012 Mar; 79(4):675-7. PubMed ID: 21805581
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prospective randomized trial of transthoracic echocardiography versus transesophageal echocardiography for assessment and guidance of transcatheter closure of atrial septal defects in children using the Amplatzer septal occluder.
    Bartakian S; El-Said HG; Printz B; Moore JW
    JACC Cardiovasc Interv; 2013 Sep; 6(9):974-80. PubMed ID: 24050864
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cobrahead Deformity in the Right Atrial Disc of a New-Generation Occlutech Figulla Flex II Atrial Septal Defect Occluder Device.
    Kilic T; Ural E; Sahin T
    Tex Heart Inst J; 2015 Oct; 42(5):454-7. PubMed ID: 26504440
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thrombus formation during percutaneous closure of an atrial septal defect with an Amplatzer septal occluder.
    Yorgun H; Canpolat U; Kaya EB; Aytemir K; Oto A
    Tex Heart Inst J; 2011; 38(4):427-30. PubMed ID: 21841876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. UK multicenter experience using the Gore septal occluder (GSO(TM) ) for atrial septal defect closure in children and adults.
    Smith B; Thomson J; Crossland D; Spence MS; Morgan GJ
    Catheter Cardiovasc Interv; 2014 Mar; 83(4):581-6. PubMed ID: 24115686
    [TBL] [Abstract][Full Text] [Related]  

  • 13. ASSURED clinical study: New GORE® CARDIOFORM ASD occluder for transcatheter closure of atrial septal defect.
    Sommer RJ; Love BA; Paolillo JA; Gray RG; Goldstein BH; Morgan GJ; Gillespie MJ;
    Catheter Cardiovasc Interv; 2020 Jun; 95(7):1285-1295. PubMed ID: 31943749
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial clinical experience with the GORE
    de Hemptinne Q; Horlick EM; Osten MD; Millán X; Tadros VX; Pighi M; Gonzalez Barlatey F; Alnasser SM; Miró J; Asgar AW; Ibrahim R
    Catheter Cardiovasc Interv; 2017 Sep; 90(3):495-503. PubMed ID: 28128523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of transcatheter closure in unselected patients with secundum atrial septal defect, using Amplatzer devices and a modified sizing balloon technique.
    Kammache I; Mancini J; Ovaert C; Habib G; Fraisse A
    Catheter Cardiovasc Interv; 2011 Nov; 78(5):665-74. PubMed ID: 21812090
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement.
    Amin Z
    Catheter Cardiovasc Interv; 2014 Jan; 83(1):84-92. PubMed ID: 24038861
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiac Erosions After Transcatheter Atrial Septal Defect Closure With the Occlutech Figulla Flex Device.
    Auriau J; Bouvaist H; Aaberge L; Abe T; Dähnert I; Panzer J; Santoro G; Khalil M; Hijazi ZM; Fraisse A
    JACC Cardiovasc Interv; 2019 Jul; 12(14):1397-1399. PubMed ID: 31320034
    [No Abstract]   [Full Text] [Related]  

  • 18. Surgical removal of an atrial septal occluder device embolized to the main pulmonary artery.
    Boysan E; Cicek OF; Cicek MC; Hamurcu Z; Gurkahraman S
    Tex Heart Inst J; 2014 Feb; 41(1):91-3. PubMed ID: 24512412
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcatheter closure of large atrial septal defects using 40 mm amplatzer septal occluder: Single group experience with short and intermediate term follow-up.
    Dalvi B; Sheth K; Jain S; Pinto R
    Catheter Cardiovasc Interv; 2017 May; 89(6):1035-1043. PubMed ID: 27862916
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fenestrated ASD device "angioplasty": How to adjust a "pop-off" mechanism when needed.
    Tufaro V; Butera G
    Catheter Cardiovasc Interv; 2018 Dec; 92(7):1329-1333. PubMed ID: 30196540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.