These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 31104178)

  • 1. Motion-corrected free-breathing LGE delivers high quality imaging and reduces scan time by half: an independent validation study.
    Captur G; Lobascio I; Ye Y; Culotta V; Boubertakh R; Xue H; Kellman P; Moon JC
    Int J Cardiovasc Imaging; 2019 Oct; 35(10):1893-1901. PubMed ID: 31104178
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Free-breathing, motion-corrected late gadolinium enhancement is robust and extends risk stratification to vulnerable patients.
    Piehler KM; Wong TC; Puntil KS; Zareba KM; Lin K; Harris DM; Deible CR; Lacomis JM; Czeyda-Pommersheim F; Cook SC; Kellman P; Schelbert EB
    Circ Cardiovasc Imaging; 2013 May; 6(3):423-32. PubMed ID: 23599309
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy.
    Cha MJ; Cho I; Hong J; Kim SW; Shin SY; Paek MY; Bi X; Kim SM
    Korean J Radiol; 2021 Jul; 22(7):1044-1053. PubMed ID: 33856138
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-throughput gadobutrol-enhanced CMR: a time and dose optimization study.
    D'Angelo T; Grigoratos C; Mazziotti S; Bratis K; Pathan F; Blandino A; Elen E; Puntmann VO; Nagel E
    J Cardiovasc Magn Reson; 2017 Nov; 19(1):83. PubMed ID: 29110679
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging.
    Munoz C; Bustin A; Neji R; Kunze KP; Forman C; Schmidt M; Hajhosseiny R; Masci PG; Zeilinger M; Wuest W; Botnar RM; Prieto C
    J Cardiovasc Magn Reson; 2020 Jul; 22(1):53. PubMed ID: 32684167
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.
    Menon RG; Miller GW; Jeudy J; Rajagopalan S; Shin T
    Magn Reson Med; 2017 Apr; 77(4):1533-1543. PubMed ID: 27122450
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical value of dark-blood late gadolinium enhancement cardiovascular magnetic resonance without additional magnetization preparation.
    Holtackers RJ; Van De Heyning CM; Nazir MS; Rashid I; Ntalas I; Rahman H; Botnar RM; Chiribiri A
    J Cardiovasc Magn Reson; 2019 Jul; 21(1):44. PubMed ID: 31352900
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of fast multi-slice and standard segmented techniques for detection of late gadolinium enhancement in ischemic and non-ischemic cardiomyopathy - a prospective clinical cardiovascular magnetic resonance trial.
    Muehlberg F; Arnhold K; Fritschi S; Funk S; Prothmann M; Kermer J; Zange L; von Knobelsdorff-Brenkenhoff F; Schulz-Menger J
    J Cardiovasc Magn Reson; 2018 Feb; 20(1):13. PubMed ID: 29458430
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography.
    Ginami G; Neji R; Rashid I; Chiribiri A; Ismail TF; Botnar RM; Prieto C
    J Cardiovasc Magn Reson; 2017 Nov; 19(1):94. PubMed ID: 29178893
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Motion-corrected free-breathing late gadolinium enhancement combined with a gadolinium contrast agent with a high relaxation rate: an optimized cardiovascular magnetic resonance examination protocol.
    Yan C; Hu J; Li Y; Xie X; Zou Z; Deng Q; Zhou X; Bi X; Zeng M; Liu J
    J Int Med Res; 2020 Oct; 48(10):300060520964664. PubMed ID: 33111603
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quality assurance of late gadolinium enhancement cardiac magnetic resonance images: a deep learning classifier for confidence in the presence or absence of abnormality with potential to prompt real-time image optimization.
    Zaman S; Vimalesvaran K; Chappell D; Varela M; Peters NS; Shiwani H; Knott KD; Davies RH; Moon JC; Bharath AA; Linton NW; Francis DP; Cole GD; Howard JP
    J Cardiovasc Magn Reson; 2024 Summer; 26(1):101040. PubMed ID: 38522522
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar.
    Francis R; Kellman P; Kotecha T; Baggiano A; Norrington K; Martinez-Naharro A; Nordin S; Knight DS; Rakhit RD; Lockie T; Hawkins PN; Moon JC; Hausenloy DJ; Xue H; Hansen MS; Fontana M
    J Cardiovasc Magn Reson; 2017 Nov; 19(1):91. PubMed ID: 29162123
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial Fibrosis in Competitive Triathletes Detected by Contrast-Enhanced CMR Correlates With Exercise-Induced Hypertension and Competition History.
    Tahir E; Starekova J; Muellerleile K; von Stritzky A; Münch J; Avanesov M; Weinrich JM; Stehning C; Bohnen S; Radunski UK; Freiwald E; Blankenberg S; Adam G; Pressler A; Patten M; Lund GK
    JACC Cardiovasc Imaging; 2018 Sep; 11(9):1260-1270. PubMed ID: 29248656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE.
    Pennig L; Lennartz S; Wagner A; Sokolowski M; Gajzler M; Ney S; Laukamp KR; Persigehl T; Bunck AC; Maintz D; Weiss K; Naehle CP; Doerner J
    J Cardiovasc Magn Reson; 2020 Dec; 22(1):89. PubMed ID: 33327958
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 'Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results'.
    Bratis K; Henningsson M; Grigoratos C; Dell'Omodarme M; Chasapides K; Botnar R; Nagel E
    J Cardiovasc Magn Reson; 2017 Dec; 19(1):97. PubMed ID: 29202776
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo ("TrueFISP") phase-sensitive inversion recovery.
    Xie LJ; Xu R; Xu ZY; Li XS; Zhou XY; Bi XM; Mu JS; Fan HM; Xu HY; Guo YK
    Clin Radiol; 2021 Jun; 76(6):471.e17-471.e25. PubMed ID: 33663913
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accelerated high-resolution free-breathing 3D whole-heart T
    Correia T; Ginami G; Rashid I; Nordio G; Hajhosseiny R; Ismail TF; Neji R; Botnar RM; Prieto C
    J Cardiovasc Magn Reson; 2020 Dec; 22(1):88. PubMed ID: 33317570
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does stress perfusion imaging improve the diagnostic accuracy of late gadolinium enhanced cardiac magnetic resonance for establishing the etiology of heart failure?
    Gulsin GS; Shetye A; Khoo J; Swarbrick DJ; Levelt E; Lai FY; Squire IB; Arnold JR; McCann GP
    BMC Cardiovasc Disord; 2017 Apr; 17(1):98. PubMed ID: 28390413
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prognosis in patients with coronary heart disease and breath-holding limitations: a free-breathing cardiac magnetic resonance protocol at 3.0 T.
    Wang K; Zhang W; Li S; Bi X; Schmidt M; An J; Zheng J; Cheng J
    BMC Cardiovasc Disord; 2021 Dec; 21(1):580. PubMed ID: 34876015
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-resolution three-dimensional late gadolinium-enhanced cardiac magnetic resonance imaging to identify the underlying substrate of ventricular arrhythmia.
    Hennig A; Salel M; Sacher F; Camaioni C; Sridi S; Denis A; Montaudon M; Laurent F; Jais P; Cochet H
    Europace; 2018 Sep; 20(FI2):f179-f191. PubMed ID: 29069369
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.