549 related articles for article (PubMed ID: 31125166)
1. Monitoring of acoustic cavitation in microbubble-presented focused ultrasound exposure using gradient-echo MRI.
Wu CH; Liu HL; Ho CT; Hsu PH; Fan CH; Yeh CK; Kang ST; Chen WS; Wang FN; Peng HH
J Magn Reson Imaging; 2020 Jan; 51(1):311-318. PubMed ID: 31125166
[TBL] [Abstract][Full Text] [Related]
2. Real-time monitoring of inertial cavitation effects of microbubbles by using MRI: In vitro experiments.
Peng HH; Wu CH; Kang ST; Zhang JW; Liu HL; Chen WS; Wang CH; Yeh CK
Magn Reson Med; 2017 Jan; 77(1):102-111. PubMed ID: 26714923
[TBL] [Abstract][Full Text] [Related]
3. Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound.
Yang FY; Lee PY
Int J Nanomedicine; 2012; 7():2573-82. PubMed ID: 22679368
[TBL] [Abstract][Full Text] [Related]
4. Static Magnetic Fields Dampen Focused Ultrasound-mediated Blood-Brain Barrier Opening.
Yang Y; Pacia CP; Ye D; Yue Y; Chien CY; Chen H
Radiology; 2021 Sep; 300(3):681-689. PubMed ID: 34227880
[TBL] [Abstract][Full Text] [Related]
5. Contrast-enhanced ultrasound imaging for the detection of focused ultrasound-induced blood-brain barrier opening.
Fan CH; Lin WH; Ting CY; Chai WY; Yen TC; Liu HL; Yeh CK
Theranostics; 2014; 4(10):1014-25. PubMed ID: 25161701
[TBL] [Abstract][Full Text] [Related]
6. Blood-brain barrier opening in a large animal model using closed-loop microbubble cavitation-based feedback control of focused ultrasound sonication.
Chien CY; Xu L; Pacia CP; Yue Y; Chen H
Sci Rep; 2022 Sep; 12(1):16147. PubMed ID: 36167747
[TBL] [Abstract][Full Text] [Related]
7. Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening.
Sun T; Samiotaki G; Wang S; Acosta C; Chen CC; Konofagou EE
Phys Med Biol; 2015 Dec; 60(23):9079-94. PubMed ID: 26562661
[TBL] [Abstract][Full Text] [Related]
8. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.
Shin J; Kong C; Cho JS; Lee J; Koh CS; Yoon MS; Na YC; Chang WS; Chang JW
Neurosurg Focus; 2018 Feb; 44(2):E15. PubMed ID: 29385915
[TBL] [Abstract][Full Text] [Related]
9. Submicron-bubble-enhanced focused ultrasound for blood-brain barrier disruption and improved CNS drug delivery.
Fan CH; Liu HL; Ting CY; Lee YH; Huang CY; Ma YJ; Wei KC; Yen TC; Yeh CK
PLoS One; 2014; 9(5):e96327. PubMed ID: 24788566
[TBL] [Abstract][Full Text] [Related]
10. Three-dimensional transcranial microbubble imaging for guiding volumetric ultrasound-mediated blood-brain barrier opening.
Jones RM; Deng L; Leung K; McMahon D; O'Reilly MA; Hynynen K
Theranostics; 2018; 8(11):2909-2926. PubMed ID: 29896293
[TBL] [Abstract][Full Text] [Related]
11. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.
Burgess MT; Apostolakis I; Konofagou EE
Phys Med Biol; 2018 Mar; 63(6):065009. PubMed ID: 29457587
[TBL] [Abstract][Full Text] [Related]
12. Microbubble type and distribution dependence of focused ultrasound-induced blood-brain barrier opening.
Wang S; Samiotaki G; Olumolade O; Feshitan JA; Konofagou EE
Ultrasound Med Biol; 2014 Jan; 40(1):130-7. PubMed ID: 24239362
[TBL] [Abstract][Full Text] [Related]
13. Blood-brain barrier: real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller.
O'Reilly MA; Hynynen K
Radiology; 2012 Apr; 263(1):96-106. PubMed ID: 22332065
[TBL] [Abstract][Full Text] [Related]
14. Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening.
Ji R; Karakatsani ME; Burgess M; Smith M; Murillo MF; Konofagou EE
J Control Release; 2021 Sep; 337():458-471. PubMed ID: 34324895
[TBL] [Abstract][Full Text] [Related]
15. Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging.
Chu PC; Chai WY; Tsai CH; Kang ST; Yeh CK; Liu HL
Sci Rep; 2016 Sep; 6():33264. PubMed ID: 27630037
[TBL] [Abstract][Full Text] [Related]
16. In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice.
Tung YS; Vlachos F; Choi JJ; Deffieux T; Selert K; Konofagou EE
Phys Med Biol; 2010 Oct; 55(20):6141-55. PubMed ID: 20876972
[TBL] [Abstract][Full Text] [Related]
17. Feedback control of microbubble cavitation for ultrasound-mediated blood-brain barrier disruption in non-human primates under magnetic resonance guidance.
Kamimura HA; Flament J; Valette J; Cafarelli A; Aron Badin R; Hantraye P; Larrat B
J Cereb Blood Flow Metab; 2019 Jul; 39(7):1191-1203. PubMed ID: 29381130
[TBL] [Abstract][Full Text] [Related]
18. Closed-loop cavitation control for focused ultrasound-mediated blood-brain barrier opening by long-circulating microbubbles.
Çavuşoğlu M; Zhang J; Ielacqua GD; Pellegrini G; Signorell RD; Papachristodoulou A; Brambilla D; Roth P; Weller M; Rudin M; Martin E; Leroux JC; Werner B
Phys Med Biol; 2019 Feb; 64(4):045012. PubMed ID: 30577029
[TBL] [Abstract][Full Text] [Related]
19. Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.
Pouliopoulos AN; Bonaccorsi S; Choi JJ
Phys Med Biol; 2014 Nov; 59(22):6941-57. PubMed ID: 25350470
[TBL] [Abstract][Full Text] [Related]
20. Targeted drug delivery with focused ultrasound-induced blood-brain barrier opening using acoustically-activated nanodroplets.
Chen CC; Sheeran PS; Wu SY; Olumolade OO; Dayton PA; Konofagou EE
J Control Release; 2013 Dec; 172(3):795-804. PubMed ID: 24096019
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]