These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

263 related articles for article (PubMed ID: 31136402)

  • 21. Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up.
    El-Chami MF; Bockstedt L; Longacre C; Higuera L; Stromberg K; Crossley G; Kowal RC; Piccini JP
    Eur Heart J; 2022 Mar; 43(12):1207-1215. PubMed ID: 34788416
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups.
    Boveda S; Higuera L; Longacre C; Wolff C; Wherry K; Stromberg K; El-Chami MF
    Europace; 2023 Mar; 25(3):1041-1050. PubMed ID: 36757859
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Leadless cardiac ventricular pacing using helix fixation: Step-by-step guide to implantation.
    Laczay B; Aguilera J; Cantillon DJ
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):748-759. PubMed ID: 36542756
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Leadless Pacemaker: a New Concept in Cardiac Pacing.
    Lopes N; Cavaco D; Carmo P; Scanavacca MI; Adragão P
    Arq Bras Cardiol; 2016 Oct; 107(4):381-382. PubMed ID: 27849261
    [No Abstract]   [Full Text] [Related]  

  • 25. Emerging Technologies in Electrophysiology: From Single-Chamber to Biventricular Leadless Pacemakers.
    Gill J
    Cardiology; 2022; 147(2):179-190. PubMed ID: 35038698
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Leadless cardiac pacing systems: current status and future prospects.
    Beurskens NEG; Breeman KTN; Dasselaar KJ; Meijer AC; Quast ABE; Tjong FVY; Knops RE
    Expert Rev Med Devices; 2019 Nov; 16(11):923-930. PubMed ID: 31657945
    [No Abstract]   [Full Text] [Related]  

  • 27. Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers.
    Cantillon DJ; Dukkipati SR; Ip JH; Exner DV; Niazi IK; Banker RS; Rashtian M; Plunkitt K; Tomassoni GF; Nabutovsky Y; Davis KJ; Reddy VY
    Heart Rhythm; 2018 Jul; 15(7):1023-1030. PubMed ID: 29957188
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Leadless pacemakers - The path to safer pacing?
    Nadarajah R; Ali N; Patel PA
    Indian Heart J; 2019; 71(6):431-433. PubMed ID: 32248913
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Leadless pacemakers: A review of current data and future directions.
    Middour TG; Chen JH; El-Chami MF
    Prog Cardiovasc Dis; 2021; 66():61-69. PubMed ID: 34332661
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Design and evaluation of the Micra Transcatheter Pacing System for bradyarrhythmia management.
    Wiles BM; Roberts PR
    Future Cardiol; 2019 Jan; 15(1):9-15. PubMed ID: 30516083
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transcatheter/leadless pacing.
    Lloyd MS; El-Chami MF; Nilsson KR; Cantillon DJ
    Heart Rhythm; 2018 Apr; 15(4):624-628. PubMed ID: 29229522
    [No Abstract]   [Full Text] [Related]  

  • 32. Leadless Pacemakers.
    El-Chami MF; Merchant FM; Leon AR
    Am J Cardiol; 2017 Jan; 119(1):145-148. PubMed ID: 27889044
    [TBL] [Abstract][Full Text] [Related]  

  • 33. State of the art: leadless ventricular pacing : A national expert consensus of the Austrian Society of Cardiology.
    Steinwender C; Lercher P; Schukro C; Blessberger H; Prenner G; Andreas M; Kraus J; Ammer M; Stühlinger M
    J Interv Card Electrophysiol; 2020 Jan; 57(1):27-37. PubMed ID: 31863250
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Safety and Efficacy of Leadless Pacemakers: A Systematic Review and Meta-Analysis.
    Ngo L; Nour D; Denman RA; Walters TE; Haqqani HM; Woodman RJ; Ranasinghe I
    J Am Heart Assoc; 2021 Jul; 10(13):e019212. PubMed ID: 34169736
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Femoral extraction of transvenous leads and leadless pacemakers-A review of the data, tools, and procedural steps.
    El-Chami MF; Merchant FM
    Pacing Clin Electrophysiol; 2019 Sep; 42(9):1248-1252. PubMed ID: 31355937
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Long-term outcomes in leadless Micra transcatheter pacemakers with elevated thresholds at implantation: Results from the Micra Transcatheter Pacing System Global Clinical Trial.
    Piccini JP; Stromberg K; Jackson KP; Laager V; Duray GZ; El-Chami M; Ellis CR; Hummel J; Jones DR; Kowal RC; Narasimhan C; Omar R; Ritter P; Roberts PR; Soejima K; Zhang S; Reynolds D;
    Heart Rhythm; 2017 May; 14(5):685-691. PubMed ID: 28111349
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Multiple leadless pacemakers implanted in the right ventricle of swine.
    Chen K; Zheng X; Dai Y; Wang H; Tang Y; Lan T; Zhang J; Tian Y; Zhang B; Zhou X; Bonner M; Zhang S
    Europace; 2016 Nov; 18(11):1748-1752. PubMed ID: 26830889
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Atrioventricular synchronous leadless pacemaker: state of art and broadened indications.
    Mitacchione G; Schiavone M; Gasperetti A; Viecca M; Curnis A; Forleo GB
    Rev Cardiovasc Med; 2021 Jun; 22(2):395-401. PubMed ID: 34258906
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transatrial implantation of transvenous pacing leads as an alternative to implantation of epicardial leads.
    Byrd CL; Schwartz SJ
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1856-9. PubMed ID: 1704554
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker.
    Reddy VY; Exner DV; Cantillon DJ; Doshi R; Bunch TJ; Tomassoni GF; Friedman PA; Estes NA; Ip J; Niazi I; Plunkitt K; Banker R; Porterfield J; Ip JE; Dukkipati SR;
    N Engl J Med; 2015 Sep; 373(12):1125-35. PubMed ID: 26321198
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.