346 related articles for article (PubMed ID: 31146202)
1. Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V).
Granato R; Bonfante EA; Castellano A; Khan R; Jimbo R; Marin C; Morsi S; Witek L; Coelho PG
J Mech Behav Biomed Mater; 2019 Sep; 97():288-295. PubMed ID: 31146202
[TBL] [Abstract][Full Text] [Related]
2. Characterization of five different implant surfaces and their effect on osseointegration: a study in dogs.
Coelho PG; Bonfante EA; Pessoa RS; Marin C; Granato R; Giro G; Witek L; Suzuki M
J Periodontol; 2011 May; 82(5):742-50. PubMed ID: 21054223
[TBL] [Abstract][Full Text] [Related]
3. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
[TBL] [Abstract][Full Text] [Related]
4. Early Healing Evaluation of Commercially Pure Titanium and Ti-6Al-4V Presenting Similar Surface Texture: An In Vivo Study.
Castellano A; Gil LF; Bonfante EA; Tovar N; Neiva R; Janal MN; Coelho PG
Implant Dent; 2017 Jun; 26(3):338-344. PubMed ID: 28406881
[TBL] [Abstract][Full Text] [Related]
5. Surface characterization, biomechanical, and histologic evaluation of alumina and bioactive resorbable blasting textured surfaces in titanium implant healing chambers: an experimental study in dogs.
Witek L; Marin C; Granato R; Bonfante EA; Campos FE; Gomes JB; Suzuki M; Coelho PG
Int J Oral Maxillofac Implants; 2013; 28(3):694-700. PubMed ID: 23748299
[TBL] [Abstract][Full Text] [Related]
6. Influence of implant surface topography on bone-regenerative potential and mechanical retention in the human maxilla and mandible.
Wei N; Bin S; Jing Z; Wei S; Yingqiong Z
Am J Dent; 2014 Jun; 27(3):171-6. PubMed ID: 25208367
[TBL] [Abstract][Full Text] [Related]
7. Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs.
Witek L; Marin C; Granato R; Bonfante EA; Campos F; Bisinotto J; Suzuki M; Coelho PG
J Biomed Mater Res B Appl Biomater; 2012 Aug; 100(6):1566-73. PubMed ID: 22692877
[TBL] [Abstract][Full Text] [Related]
8. Surface characterization and in vivo evaluation of dual Acid-etched and grit-blasted/acid-etched implants in sheep.
Yoo D; Marin C; Freitas G; Tovar N; Bonfante EA; Teixeira HS; Janal MN; Coelho PG
Implant Dent; 2015 Jun; 24(3):256-62. PubMed ID: 25860908
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical and histologic evaluation of non-washed resorbable blasting media and alumina-blasted/acid-etched surfaces.
Coelho PG; Marin C; Granato R; Giro G; Suzuki M; Bonfante EA
Clin Oral Implants Res; 2012 Jan; 23(1):132-5. PubMed ID: 21435012
[TBL] [Abstract][Full Text] [Related]
10. The effect of implant diameter on osseointegration utilizing simplified drilling protocols.
Jimbo R; Janal MN; Marin C; Giro G; Tovar N; Coelho PG
Clin Oral Implants Res; 2014 Nov; 25(11):1295-1300. PubMed ID: 25040139
[TBL] [Abstract][Full Text] [Related]
11. Histomorphological and Histomorphometric Analyses of Grade IV Commercially Pure Titanium and Grade V Ti-6Al-4V Titanium Alloy Implant Substrates: An In Vivo Study in Dogs.
Ribeiro da Silva J; Castellano A; Malta Barbosa JP; Gil LF; Marin C; Granato R; Bonfante EA; Tovar N; Janal MN; Coelho PG
Implant Dent; 2016 Oct; 25(5):650-5. PubMed ID: 27540838
[TBL] [Abstract][Full Text] [Related]
12. The effect of controlled microrobotized blasting on implant surface texturing and early osseointegration.
Gil LF; Marin C; Teixeira H; Marão HF; Tovar N; Khan R; Bonfante EA; Janal M; Coelho PG
J Biomater Appl; 2016 Feb; 30(7):900-7. PubMed ID: 26508287
[TBL] [Abstract][Full Text] [Related]
13. Microrobotized blasting improves the bone-to-textured implant response. A preclinical in vivo biomechanical study.
Coelho PG; Gil LF; Neiva R; Jimbo R; Tovar N; Lilin T; Bonfante EA
J Mech Behav Biomed Mater; 2016 Mar; 56():175-182. PubMed ID: 26703231
[TBL] [Abstract][Full Text] [Related]
14. Effect of H2O2/HCl heat treatment of implants on in vivo peri-implant bone formation.
Yang GL; He FM; Zhao SS; Wang XX; Zhao SF
Int J Oral Maxillofac Implants; 2008; 23(6):1020-8. PubMed ID: 19216270
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical and bone histomorphologic evaluation of four surfaces on plateau root form implants: an experimental study in dogs.
Coelho PG; Granato R; Marin C; Bonfante EA; Janal MN; Suzuki M
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 May; 109(5):e39-45. PubMed ID: 20416517
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical and histomorphometric properties of four different mini-implant surfaces.
Yadav S; Upadhyay M; Roberts WE
Eur J Orthod; 2015 Dec; 37(6):627-35. PubMed ID: 25681126
[TBL] [Abstract][Full Text] [Related]
17. The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model.
Feighan JE; Goldberg VM; Davy D; Parr JA; Stevenson S
J Bone Joint Surg Am; 1995 Sep; 77(9):1380-95. PubMed ID: 7673290
[TBL] [Abstract][Full Text] [Related]
18. Comparative in vivo study of alloy titanium implants with two different surfaces: biomechanical and SEM analysis.
Souza FÁ; Furtado TSM; Dayube URC; Melo WM; Nishioka RS; Poli PP; Maiorana C; de Carvalho PSP
Clin Oral Investig; 2019 Dec; 23(12):4383-4397. PubMed ID: 30972600
[TBL] [Abstract][Full Text] [Related]
19. Removal torque and histomorphometric evaluation of bioceramic grit-blasted/acid-etched and dual acid-etched implant surfaces: an experimental study in dogs.
Marin C; Granato R; Suzuki M; Gil JN; Piattelli A; Coelho PG
J Periodontol; 2008 Oct; 79(10):1942-9. PubMed ID: 18834250
[TBL] [Abstract][Full Text] [Related]
20. Influence of acid-etching after grit-blasted on osseointegration of titanium dental implants: in vitro and in vivo studies.
Herrero-Climent M; Lázaro P; Vicente Rios J; Lluch S; Marqués M; Guillem-Martí J; Gil FJ
J Mater Sci Mater Med; 2013 Aug; 24(8):2047-55. PubMed ID: 23625320
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]