156 related articles for article (PubMed ID: 31152695)
1. Analytical performance evaluation of the Elecsys® Troponin T Gen 5 STAT assay.
Fitzgerald RL; Hollander JE; Peacock WF; Limkakeng AT; Breitenbeck N; Blechschmidt K; Laimighofer M; deFilippi C
Clin Chim Acta; 2019 Aug; 495():522-528. PubMed ID: 31152695
[TBL] [Abstract][Full Text] [Related]
2. Evaluating the performance of an updated high-sensitivity troponin T assay with increased tolerance to biotin.
von Meyer A; Albert G; Kunzelmann S; Rank C; Zerback R; Imdahl R
Clin Chem Lab Med; 2021 Feb; 59(3):591-597. PubMed ID: 33112775
[TBL] [Abstract][Full Text] [Related]
3. Results from a multicenter evaluation of the 4th generation Elecsys Troponin T assay.
Hermsen D; Apple F; Garcia-Beltràn L; Jaffe A; Karon B; Lewandrowski E; Mühlbacher A; Müller R; Ordóñez J; Pagani F; Panteghini M; Plecko T; Jarausch J
Clin Lab; 2007; 53(1-2):1-9. PubMed ID: 17323819
[TBL] [Abstract][Full Text] [Related]
4. Analytical and Clinical Validation of a Point-of-Care Cardiac Troponin T Test with an Improved Detection Limit.
Jungbauer C; Hupf J; Giannitsis E; Frick J; Slagman A; Ehret C; Herbert N; Jung C; Zerback R; Bertsch T; Christ M
Clin Lab; 2017 Apr; 63(4):633-645. PubMed ID: 28397461
[TBL] [Abstract][Full Text] [Related]
5. The 99th percentile upper reference limit for the 5th generation cardiac troponin T assay in the United States.
Fitzgerald RL; Hollander JE; Peacock WF; Limkakeng AT; Breitenbeck N; Rivers EJ; Ziegler A; Laimighofer M; deFilippi C
Clin Chim Acta; 2020 May; 504():172-179. PubMed ID: 32001233
[TBL] [Abstract][Full Text] [Related]
6. Clinical risk assessment of biotin interference with a high-sensitivity cardiac troponin T assay.
Mumma B; Diercks D; Twerenbold R; Valcour A; Ziegler A; Schützenmeister A; Kasapic D; Tran N
Clin Chem Lab Med; 2020 Oct; 58(11):1931-1940. PubMed ID: 32804676
[TBL] [Abstract][Full Text] [Related]
7. Profile of Roche's Elecsys Troponin T Gen 5 STAT blood test (a high-sensitivity cardiac troponin assay) for diagnosing myocardial infarction in the emergency department.
Kavsak PA; Andruchow JE; McRae AD; Worster A
Expert Rev Mol Diagn; 2018 Jun; 18(6):481-489. PubMed ID: 29756512
[TBL] [Abstract][Full Text] [Related]
8. A new immunochemistry platform for a guideline-compliant cardiac troponin T assay at the point of care: proof of principle.
Lopez-Calle E; Espindola P; Spinke J; Lutz S; Nichtl A; Tgetgel A; Herbert N; Marcinowski M; Klepp J; Fischer T; Brueckner T; Boehm C; Keller T
Clin Chem Lab Med; 2017 Oct; 55(11):1798-1804. PubMed ID: 28375843
[TBL] [Abstract][Full Text] [Related]
9. Analytical validation of a high-sensitivity cardiac troponin T assay.
Giannitsis E; Kurz K; Hallermayer K; Jarausch J; Jaffe AS; Katus HA
Clin Chem; 2010 Feb; 56(2):254-61. PubMed ID: 19959623
[TBL] [Abstract][Full Text] [Related]
10. Sex-specific 99th percentiles derived from the AACC Universal Sample Bank for the Roche Gen 5 cTnT assay: Comorbidities and statistical methods influence derivation of reference limits.
Gunsolus IL; Jaffe AS; Sexter A; Schulz K; Ler R; Lindgren B; Saenger AK; Love SA; Apple FS
Clin Biochem; 2017 Dec; 50(18):1073-1077. PubMed ID: 28916437
[TBL] [Abstract][Full Text] [Related]
11. Clinical performance of the new cardiac markers troponin T and CK-MB on the Elecsys 2010. A multicentre evaluation.
Klein G; Kampmann M; Baum H; Rauscher T; Vukovic T; Hallermayer K; Rehner H; Müller-Bardorff M; Katus HA
Wien Klin Wochenschr; 1998; 110 Suppl 3():40-51. PubMed ID: 9677671
[TBL] [Abstract][Full Text] [Related]
12. Analytical evaluation of a high-sensitivity troponin T assay and its clinical assessment in acute coronary syndrome.
Chenevier-Gobeaux C; Meune C; Blanc MC; Cynober L; Jaffray P; Lefevre G
Ann Clin Biochem; 2011 Sep; 48(Pt 5):452-8. PubMed ID: 21697353
[TBL] [Abstract][Full Text] [Related]
13. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays.
Harley K; Bissonnette S; Inzitari R; Schulz K; Apple FS; Kavsak PA; Gunsolus IL
Clin Chem Lab Med; 2021 Jul; 59(8):1431-1443. PubMed ID: 33761581
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T.
Wang J; Fang Y; Li P; Lin H; Jin H; Gao L; Ge S; Zhang ZY
J Clin Lab Anal; 2018 Mar; 32(3):. PubMed ID: 28940712
[TBL] [Abstract][Full Text] [Related]
15. Reference population and marathon runner sera assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and I assays.
Mingels A; Jacobs L; Michielsen E; Swaanenburg J; Wodzig W; van Dieijen-Visser M
Clin Chem; 2009 Jan; 55(1):101-8. PubMed ID: 18988757
[TBL] [Abstract][Full Text] [Related]
16. Discordance with 3 Cardiac Troponin I and T Assays: Implications for the 99th Percentile Cutoff.
Ungerer JP; Tate JR; Pretorius CJ
Clin Chem; 2016 Aug; 62(8):1106-14. PubMed ID: 27335076
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Performance between the Elecsys 4
Barbhuiya MA; Neibauer T; Saylor E; Zhu Y
Ann Clin Lab Sci; 2022 Jul; 52(4):628-633. PubMed ID: 36197775
[TBL] [Abstract][Full Text] [Related]
18. Biotin and high-sensitivity cardiac troponin T assay.
Schrapp A; Fraissinet F; Hervouet C; Girot H; Brunel V
Biochem Med (Zagreb); 2018 Oct; 28(3):030901. PubMed ID: 30429682
[TBL] [Abstract][Full Text] [Related]
19. Reference values of galectin-3 and cardiac troponins derived from a single cohort of healthy blood donors.
Mueller T; Egger M; Leitner I; Gabriel C; Haltmayer M; Dieplinger B
Clin Chim Acta; 2016 May; 456():19-23. PubMed ID: 26920637
[TBL] [Abstract][Full Text] [Related]
20. [Performance and clinical utility of a high-sensitivity troponin T assay].
Okura H; Suzuki R; Sugibayashi S; Yoshika M; Takahashi H
Rinsho Byori; 2012 May; 60(5):407-13. PubMed ID: 22774568
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]