BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

397 related articles for article (PubMed ID: 31153555)

  • 1. The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung.
    Perl RM; Risse E; Hetzel J; Bösmüller H; Kloth C; Fritz J; Horger M
    Eur J Radiol; 2019 Jul; 116():14-20. PubMed ID: 31153555
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.
    Graffy P; Loomis SB; Pickhardt PJ; Lubner MG; Kitchin DR; Lee FT; Hinshaw JL
    J Vasc Interv Radiol; 2017 Apr; 28(4):608-613.e1. PubMed ID: 28185770
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pneumothorax Incidence with Normal Saline Instillation for Sealing the Needle Track After Computed Tomography-Guided Percutaneous Lung Biopsy.
    Bourgeais G; Frampas E; Liberge R; Nicolas A; Defrance C; Blanc FX; Coudol S; Morla O
    Cardiovasc Intervent Radiol; 2024 May; 47(5):604-612. PubMed ID: 38263525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube Placement.
    Drumm O; Joyce EA; de Blacam C; Gleeson T; Kavanagh J; McCarthy E; McDermott R; Beddy P
    Radiology; 2019 Jul; 292(1):190-196. PubMed ID: 31084480
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effectiveness of autologous blood injection in reducing the rate of pneumothorax after percutaneous lung core needle biopsy.
    Turgut B; Duran FM; Bakdık S; Arslan S; Tekin AF; Esme H
    Diagn Interv Radiol; 2020 Sep; 26(5):470-475. PubMed ID: 32755876
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions.
    Li Y; Du Y; Yang HF; Yu JH; Xu XX
    Clin Radiol; 2013 Jan; 68(1):e43-8. PubMed ID: 23177650
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pneumothorax Rate and Diagnostic Adequacy of Computed Tomography-guided Lung Nodule Biopsies Performed With 18 G Versus 20 G Needles: A Cross-Sectional Study.
    Kolderman NC; Cheti DR; Hasbrook CD; Forsyth AJ; Coffey MP; Nair GB; Al-Katib SA
    J Thorac Imaging; 2020 Jul; 35(4):265-269. PubMed ID: 32032253
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CT-guided lung biopsies: pleural blood patching reduces the rate of chest tube placement for postbiopsy pneumothorax.
    Wagner JM; Hinshaw JL; Lubner MG; Robbins JB; Kim DH; Pickhardt PJ; Lee FT
    AJR Am J Roentgenol; 2011 Oct; 197(4):783-8. PubMed ID: 21940564
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Core Lung Biopsy for Biomarker Analysis: Is There Increased Risk Compared With Conventional Biopsy?
    Sheth S; Jilani D; Bos A; Ahmed O; Patel M; Zangan S
    J Thorac Imaging; 2015 Sep; 30(5):314-8. PubMed ID: 25961378
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax.
    Appel E; Dommaraju S; Camacho A; Nakhaei M; Siewert B; Ahmed M; Brook A; Brook OR
    Eur Radiol; 2020 Nov; 30(11):6369-6375. PubMed ID: 32591892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pneumothorax after computed tomography-guided lung biopsy: Utility of immediate post-procedure computed tomography and one-hour delayed chest radiography.
    Weinand JT; du Pisanie L; Ngeve S; Commander C; Yu H
    PLoS One; 2023; 18(4):e0284145. PubMed ID: 37075048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of a Dehydrated Hydrogel Plug to Reduce Complications Associated With Computed Tomography-guided Percutaneous Transthoracic Needle Biopsy.
    Grage RA; Naveed MA; Keogh S; Wang D
    J Thorac Imaging; 2017 Jan; 32(1):57-62. PubMed ID: 27870824
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
    Nakamura M; Yoshizako T; Koyama S; Kitagaki H
    J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnostic Accuracy and Safety of CT-Guided Percutaneous Transthoracic Needle Biopsies: 14-Gauge versus 22-Gauge Needles.
    Ocak S; Duplaquet F; Jamart J; Pirard L; Weynand B; Delos M; Eucher P; Rondelet B; Dupont M; Delaunois L; Sibille Y; Dahlqvist C
    J Vasc Interv Radiol; 2016 May; 27(5):674-81. PubMed ID: 27017121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computed tomography-guided percutaneous lung biopsy: impact of lesion proximity to diaphragm on biopsy yield and pneumothorax rate.
    Patel MV; Ahmed O; Jilani D; Zangan S
    J Thorac Imaging; 2014 Nov; 29(6):344-9. PubMed ID: 25314026
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Retrospective Analysis of the Effectiveness of Extrapleural Autologous Blood Patch Injection on Pneumothorax and Intervention Need in CT-guided Lung Biopsy.
    Türk Y; Devecioğlu İ
    Cardiovasc Intervent Radiol; 2021 Aug; 44(8):1223-1230. PubMed ID: 34021378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.