These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 31156321)

  • 21. Investigation of multifilament MgB
    Yoo BH; Kim JC; Kim YG; Hwang DY; Lee JH; Lee HG
    Rev Sci Instrum; 2018 Sep; 89(9):094701. PubMed ID: 30278739
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Note: Progress on the use of MgB
    Kim YG; Song JB; Kim JC; Kim JM; Yoo BH; Yun SB; Hwang DY; Lee HG
    Rev Sci Instrum; 2017 Aug; 88(8):086105. PubMed ID: 28863663
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Persistent-current switch for pancake coils of rare earth-barium-copper-oxide high-temperature superconductor: Design and test results of a double-pancake coil operated in liquid nitrogen (77-65 K) and in solid nitrogen (60-57 K).
    Qu T; Michael PC; Voccio J; Bascuñán J; Hahn S; Iwasa Y
    Appl Phys Lett; 2016 Aug; 109(8):082601. PubMed ID: 27647942
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Design, construction, and operation of a 2 T 240 mm conduction-cooled defect-irrelevant winding (RE) Ba
    Bong U; Choi K; Kim J; Bang J; Lee JT; Im C; Park J; Yoon J; Kim G; Ku H; Kang W; Hahn S
    Rev Sci Instrum; 2022 Jul; 93(7):073302. PubMed ID: 35922323
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanical analysis of an MgB
    Poole C; Al Amin A; Baig T; Martens M
    Cryogenics (Guildf); 2019 Jun; 100():18-27. PubMed ID: 32764833
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Quench, Normal Zone Propagation Velocity, and the Development of an Active Protection Scheme for a Conduction Cooled, R&W, MgB
    Zhang D; Sumption MD; Majoros M; Kovacs C; Collings EW; Panik D; Rindfleisch M; Doll D; Tomsic M; Poole C; Martens M
    Supercond Sci Technol; 2019 Dec; 32(12):. PubMed ID: 34113064
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A REBCO Persistent-Current Switch (PCS): Test Results and Switch Heater Performance.
    Michael PC; Qu T; Voccio J; Bascuñán J; Hahn S; Iwasa Y
    IEEE Trans Appl Supercond; 2017 Jun; 27(4):. PubMed ID: 31289432
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High-Temperature Superconducting Magnets for NMR and MRI: R&D Activities at the MIT Francis Bitter Magnet Laboratory.
    Iwasa Y; Bascuñán J; Hahn S; Tomita M; Yao W
    IEEE Trans Appl Supercond; 2010 Jun; 20(3):718-721. PubMed ID: 33132668
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Solid Nitrogen Cooled MgB(2) "Demonstration" Coil for MRI Applications.
    Yao W; Bascuñán J; Kim WS; Hahn S; Lee H; Iwasa Y
    IEEE Trans Appl Supercond; 2008; 18(2):912-915. PubMed ID: 20390056
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Conceptual design of the superconducting magnet for the 250 MeV proton cyclotron.
    Ren Y; Liu X; Gao X
    Springerplus; 2016; 5(1):673. PubMed ID: 27350910
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hydrogen Cooling Options for MgB
    Stautner W; Xu M; Mine S; Amm K
    AIP Conf Proc; 2014 Jan; 1573(1):82-90. PubMed ID: 35444353
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of Low Annealing Temperature on the Critical-Current Density of 2% C-Doped MgB
    Czujko T; Gajda D; Rindfleisch M; Babij M; Zaleski A
    Materials (Basel); 2023 Sep; 16(18):. PubMed ID: 37763435
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A Cryogen-Free 25-T REBCO Magnet with the Extreme-No-Insulation Winding Technique.
    Park D; Lee W; Bascuñán J; Kim HM; Iwasa Y
    IEEE Trans Appl Supercond; 2022 Sep; 32(6):. PubMed ID: 36185339
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Finite element analysis of the temperature distribution within a Conduction-Cooled, MgB
    Zhang D; Sumption MD; Majoros M; Collings EW; Panik D; Rindfleisch M; Doll D; Tomsic MJ
    Cryogenics (Guildf); 2022 Oct; 127():. PubMed ID: 37842207
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Watch-sized 12 Tesla all-high-temperature-superconducting magnet.
    Chen PH; Gao C; Alaniva N; Björgvinsdóttir S; Pagonakis IG; Urban MA; Däpp A; Gunzenhauser R; Barnes AB
    J Magn Reson; 2023 Dec; 357():107588. PubMed ID: 37976810
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Conceptual Design of a Portable, Solid-Nitrogen-Cooled 0.5-T/560-mm Point-of-Care MRI Magnet.
    Park D; Bascuñán J; Lee W; Iwasa Y
    IEEE Trans Appl Supercond; 2023 Aug; 33(5):. PubMed ID: 37638131
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Niobium-titanium (Nb-Ti) superconducting joints for persistent-mode operation.
    Patel D; Kim SH; Qiu W; Maeda M; Matsumoto A; Nishijima G; Kumakura H; Choi S; Kim JH
    Sci Rep; 2019 Oct; 9(1):14287. PubMed ID: 31582758
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On the 600 MHz HTS Insert for a 1.3 GHz NMR Magnet.
    Bascuñán J; Hahn S; Park DK; Kim Y; Iwasa Y
    IEEE Trans Appl Supercond; 2012 Jun; 22(3):. PubMed ID: 31171896
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Designs and Tests of Shaking Coils to Reduce Screening Currents Induced in HTS Insert Coils for NMR Magnet.
    Kajikawa K; Gettliffe GV; Chu Y; Miyagi D; Lécrevisse TP; Hahn S; Bascuñán J; Iwasa Y
    IEEE Trans Appl Supercond; 2015 Jun; 25(3):. PubMed ID: 32952375
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Superconducting magnet performance for 28 GHz electron cyclotron resonance ion source developed at the Korea Basic Science Institute.
    Park JY; Choi S; Lee BS; Yoon JH; Ok JW; Kim BC; Shin CS; Ahn JK; Won MS
    Rev Sci Instrum; 2014 Feb; 85(2):02A928. PubMed ID: 24593507
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.