1. Clinical validation of a new metabolic monitor suitable for use in critically ill patients.
Nelson LD; Anderson HB; Garcia H
Crit Care Med; 1987 Oct; 15(10):951-7. PubMed ID: 3115680
[TBL] [Abstract][Full Text] [Related]
2. Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.
Rosenbaum A; Kirby C; Breen PH
Anesthesiology; 2004 Jun; 100(6):1427-37. PubMed ID: 15166562
[TBL] [Abstract][Full Text] [Related]
3. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
Brandi LS; Bertolini R; Santini L; Cavani S
Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
[TBL] [Abstract][Full Text] [Related]
4. A Device for the Quantification of Oxygen Consumption and Caloric Expenditure in the Neonatal Range.
Nachman E; Clemensen P; Santos K; Cole AR; Polizzotti BD; Hofmann G; Leeman KT; van den Bosch SJ; Kheir JN
Anesth Analg; 2018 Jul; 127(1):95-104. PubMed ID: 29505450
[TBL] [Abstract][Full Text] [Related]
5. Ventilatory response to high caloric loads in critically ill patients.
Liposky JM; Nelson LD
Crit Care Med; 1994 May; 22(5):796-802. PubMed ID: 8181288
[TBL] [Abstract][Full Text] [Related]
6. A ventilator with an integrated gas-exchange monitoring function.
Weyland W; Weyland A; Gefeller O; al-Soufi S; Sydow M; Braun U
Crit Care Med; 1994 May; 22(5):864-71. PubMed ID: 8181298
[TBL] [Abstract][Full Text] [Related]
7. A multipatient mass spectrometer based system for the measurement of metabolic gas exchange in artificially ventilated intensive care patients.
Roberts MJ; Boustred ML; Hinds CJ
Intensive Care Med; 1983; 9(6):339-43. PubMed ID: 6418783
[TBL] [Abstract][Full Text] [Related]
8. Carbon dioxide production during mechanical ventilation.
Henneberg S; Söderberg D; Groth T; Stjernström H; Wiklund L
Crit Care Med; 1987 Jan; 15(1):8-13. PubMed ID: 3098501
[TBL] [Abstract][Full Text] [Related]
9. Effect of FiO
Ferreruela M; Raurich JM; Llompart-Pou JA; Colomar A; Ayestarán I
Med Intensiva; 2017 Nov; 41(8):461-467. PubMed ID: 28283325
[TBL] [Abstract][Full Text] [Related]
10. The effects of endotracheal suctioning on the accuracy of oxygen consumption and carbon dioxide production measurements and pulmonary mechanics calculated by a compact metabolic monitor.
Briassoulis G; Briassoulis P; Michaeloudi E; Fitrolaki DM; Spanaki AM; Briassouli E
Anesth Analg; 2009 Sep; 109(3):873-9. PubMed ID: 19690260
[TBL] [Abstract][Full Text] [Related]
11. In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates.
Behrends M; Kernbach M; Bräuer A; Braun U; Peters J; Weyland W
Intensive Care Med; 2001 Jan; 27(1):228-35. PubMed ID: 11280640
[TBL] [Abstract][Full Text] [Related]
12. Comparison of metabolic monitors in critically ill, ventilated patients.
Singer P; Pogrebetsky I; Attal-Singer J; Cohen J
Nutrition; 2006; 22(11-12):1077-86. PubMed ID: 16973331
[TBL] [Abstract][Full Text] [Related]
13. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer.
Zenger M; Brenner M; Hua P; Haruno M; Wilson AF
Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286
[TBL] [Abstract][Full Text] [Related]
14. Metabolic measurements in the critically ill.
Weissman C; Kemper M
Crit Care Clin; 1995 Jan; 11(1):169-97. PubMed ID: 7736266
[TBL] [Abstract][Full Text] [Related]
15. Methods to validate the accuracy of an indirect calorimeter in the in-vitro setting.
Oshima T; Ragusa M; Graf S; Dupertuis YM; Heidegger CP; Pichard C
Clin Nutr ESPEN; 2017 Dec; 22():71-75. PubMed ID: 29415838
[TBL] [Abstract][Full Text] [Related]
16. Validation of a compact system for measuring gas exchange.
Eccles RC; Swinamer DL; Jones RL; King EG
Crit Care Med; 1986 Sep; 14(9):807-11. PubMed ID: 3091320
[TBL] [Abstract][Full Text] [Related]
17. Technical and clinical testing of a computerized indirect calorimeter for use in mechanically ventilated neonates.
Mayfield SR
Am J Clin Nutr; 1991 Jul; 54(1):30-4. PubMed ID: 1905477
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of an apparatus for continuous monitoring of gas exchange in mechanically ventilated patients.
Carlsson M; Forsberg E; Thörne A; Nordenström J; Hedenstierna G
Int J Clin Monit Comput; 1985; 1(4):211-20. PubMed ID: 3836285
[TBL] [Abstract][Full Text] [Related]
19. Ventilatory and metabolic responses to acute hyperoxia in newborns.
Mortola JP; Frappell PB; Dotta A; Matsuoka T; Fox G; Weeks S; Mayer D
Am Rev Respir Dis; 1992 Jul; 146(1):11-5. PubMed ID: 1626793
[TBL] [Abstract][Full Text] [Related]
20. Influence of different ventilator modes on Vo(2) and Vco(2) measurements using a compact metabolic monitor.
Briassoulis G; Michaeloudi E; Fitrolaki DM; Spanaki AM; Briassouli E
Nutrition; 2009; 25(11-12):1106-14. PubMed ID: 19502007
[TBL] [Abstract][Full Text] [Related]