These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

363 related articles for article (PubMed ID: 31165917)

  • 21. Prospective randomized controlled trial comparing dynamic hip screw and screw fixation for undisplaced subcapital hip fractures.
    Watson A; Zhang Y; Beattie S; Page RS
    ANZ J Surg; 2013 Sep; 83(9):679-83. PubMed ID: 22998439
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of young femoral neck fractures treated by femoral neck system, multiple cancellous screws and dynamic hip screws: a retrospectively comparison study.
    Cai L; Zheng W; Chen C; Hu W; Chen H; Wang T
    BMC Musculoskelet Disord; 2024 Mar; 25(1):188. PubMed ID: 38431562
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel screws?
    Hoshino CM; Christian MW; O'Toole RV; Manson TT
    Injury; 2016 Aug; 47(8):1676-84. PubMed ID: 27269418
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults.
    Zheng S; Lin D; Chen P; Lin C; Chen B; Zheng K; Lin F
    Injury; 2024 Jun; 55(6):111564. PubMed ID: 38640596
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Fixation with cancellous screws and fibular strut grafts for neglected femoral neck fractures.
    Pal CP; Kumar B; Dinkar KS; Singh P; Kumar H; Goyal RK
    J Orthop Surg (Hong Kong); 2014 Aug; 22(2):181-5. PubMed ID: 25163951
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials.
    Arirachakaran A; Amphansap T; Thanindratarn P; Piyapittayanun P; Srisawat P; Kongtharvonskul J
    Eur J Orthop Surg Traumatol; 2017 Oct; 27(7):937-952. PubMed ID: 28434124
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients.
    Parker M; Cawley S; Palial V
    Bone Joint J; 2013 Oct; 95-B(10):1402-5. PubMed ID: 24078540
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The choice of screw internal fixation and hemiarthroplasty in the treatment of femoral neck fractures in the elderly: a meta-analysis.
    Cui S; Wang D; Wang X; Li Z; Guo W
    J Orthop Surg Res; 2020 Sep; 15(1):433. PubMed ID: 32958029
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [PROSPECTIVE RANDOMIZED CONTROLLED STUDY ON TREATMENT OF DISPLACED FEMORAL NECK FRACTURES WITH PERCUTANEOUS COMPRESSION PLATE].
    Yin Q; Gu S; Wang J; Li H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):951-955. PubMed ID: 29786223
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hemiarthroplasty compared with internal fixation for treatment of nondisplaced femoral neck fractures in elderly patients: a retrospective study.
    Chen JY; She GR; Luo SM; Wu WR; Zhuang TF; Huan SW; Liu N; Zha ZG
    Injury; 2020 Apr; 51(4):1021-1024. PubMed ID: 32147143
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Complications following young femoral neck fractures.
    Slobogean GP; Sprague SA; Scott T; Bhandari M
    Injury; 2015 Mar; 46(3):484-91. PubMed ID: 25480307
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Long-term outcome of patients with avascular necrosis, after internal fixation of femoral neck fractures.
    Nikolopoulos KE; Papadakis SA; Kateros KT; Themistocleous GS; Vlamis JA; Papagelopoulos PJ; Nikiforidis PA
    Injury; 2003 Jul; 34(7):525-8. PubMed ID: 12832180
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.
    Willey M; Welsh ML; Roth TS; Koval KJ; Nepola JV
    Iowa Orthop J; 2018; 38():61-71. PubMed ID: 30104926
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Angular stable multiple screw fixation (Targon FN) versus standard SHS for the fixation of femoral neck fractures.
    Eschler A; Brandt S; Gierer P; Mittlmeier T; Gradl G
    Injury; 2014 Jan; 45 Suppl 1():S76-80. PubMed ID: 24268670
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A New Method to Protect Blood Supply in the Treatment of Femoral Neck Fractures: Bidirectional Compression Porous Tantalum Screws.
    Zhao D; Ma Z; Liu B; Yang L; Qiu X; Tian S; Okoye CS; Lian Z
    Orthop Surg; 2022 Sep; 14(9):1964-1971. PubMed ID: 35848152
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Treatment and outcomes of basicervical femoral neck fractures: A systematic review.
    Dekhne MS; Thomas HM; Haider T; Mortensen S; Rodriguez EK; Weaver MJ; von Keudell A
    J Orthop Surg (Hong Kong); 2021; 29(1):23094990211003344. PubMed ID: 33779387
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Proximal femoral nails antirotation, Gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: A meta-analysis.
    Ma KL; Wang X; Luan FJ; Xu HT; Fang Y; Min J; Luan HX; Yang F; Zheng H; He SJ
    Orthop Traumatol Surg Res; 2014 Dec; 100(8):859-66. PubMed ID: 25453927
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pilot study of three novel implants-GSK triangular system, locking hip screw and controlled sliding dynamic hip screw, for fixation of fracture of the neck of femur.
    Kulkarni GS; Kulkarni S; Malve S; Kulkarni V; Kulkarni M; Kulkarni S; Kulkarni M; Kulkarni R
    Injury; 2024 Jun; 55 Suppl 2():111594. PubMed ID: 39098789
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2004; (1):CD000093. PubMed ID: 14973946
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dyslipidaemia for patients with low-energy femoral neck fractures after the treatment of cancellous screws: a retrospective study with a 3-year minimum follow-up.
    Zhang C; Zhu X; Pei G; Xu P; Zeng X; Zhang L; Zhang N; Zeng D; Cao L; Yu W; Zhang X
    BMC Musculoskelet Disord; 2017 Nov; 18(1):440. PubMed ID: 29126401
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.