113 related articles for article (PubMed ID: 31167171)
1. Feasibility of fast non local means filter in pediatric chest x-ray for increasing of pulmonary nodule detectability with 3D printed lung nodule phantom.
Shim J; Yoon M; Lee Y
J Radiol Prot; 2019 Sep; 39(3):872-890. PubMed ID: 31167171
[TBL] [Abstract][Full Text] [Related]
2. Utility of fast non-local means (FNLM) filter for detection of pulmonary nodules in chest CT for pediatric patient.
Shim J; Yoon M; Lee MJ; Lee Y
Phys Med; 2021 Jan; 81():52-59. PubMed ID: 33440281
[TBL] [Abstract][Full Text] [Related]
3. Relationship Between Tube Voltage and Physical Image Quality of Pulmonary Nodules on Chest Radiographs Obtained Using the Bone-Suppression Technique.
Takagi S; Yaegashi T; Ishikawa M
Acad Radiol; 2019 Jul; 26(7):e174-e179. PubMed ID: 30269955
[TBL] [Abstract][Full Text] [Related]
4. [Study of X-ray filter and peak kilovoltage in Fuji Computed Radiography in regard to the detection of simulated pulmonary nodules].
Kiyono K; Sone S; Sakai F; Kawai T; Karakida O; Oguchi K; Kasuga T; Hirano H; Miyasaka T; Matsumoto T
Nihon Igaku Hoshasen Gakkai Zasshi; 1994 Oct; 54(12):1126-35. PubMed ID: 9340603
[TBL] [Abstract][Full Text] [Related]
5. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
[TBL] [Abstract][Full Text] [Related]
6. Lung nodule conspicuity using unsharp mask filters with storage-phosphor-based computed radiography.
Li F; Sone S; Kiyono K
Acta Radiol; 1997 Jan; 38(1):99-103. PubMed ID: 9059410
[TBL] [Abstract][Full Text] [Related]
7. Optimizing dual-energy x-ray parameters for the ExacTrac clinical stereoscopic imaging system to enhance soft-tissue imaging.
Bowman WA; Robar JL; Sattarivand M
Med Phys; 2017 Mar; 44(3):823-831. PubMed ID: 28060412
[TBL] [Abstract][Full Text] [Related]
8. Systematic error in lung nodule volumetry: effect of iterative reconstruction versus filtered back projection at different CT parameters.
Willemink MJ; Leiner T; Budde RP; de Kort FP; Vliegenthart R; van Ooijen PM; Oudkerk M; de Jong PA
AJR Am J Roentgenol; 2012 Dec; 199(6):1241-6. PubMed ID: 23169714
[TBL] [Abstract][Full Text] [Related]
9. [Optimal Beam Quality in Chest Radiography Using CsI-flat Panel Detector for Detection of Pulmonary Nodules].
Oda N; Tabata Y; Mizuta M; Asada Y; Nakano T; Hara T; Kurokawa Y; Aoki T; Uehara S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021; 77(4):335-343. PubMed ID: 33883367
[TBL] [Abstract][Full Text] [Related]
10. Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted).
Ebner L; Bütikofer Y; Ott D; Huber A; Landau J; Roos JE; Heverhagen JT; Christe A
AJR Am J Roentgenol; 2015 Apr; 204(4):727-35. PubMed ID: 25794062
[TBL] [Abstract][Full Text] [Related]
11. Capability for dose reduction while maintaining nodule detection: Comparison of silver and copper X-ray spectrum modulation filters for chest CT using a phantom study with different reconstruction methods.
Oshima Y; Ohno Y; Takenaka D; Ito Y; Kimata H; Fujii K; Akino N; Hamabuchi N; Matsuyama T; Nagata H; Ueda T; Ikeda H; Ozawa Y; Yoshikawa T; Toyama H
Eur J Radiol; 2023 Sep; 166():110969. PubMed ID: 37454556
[TBL] [Abstract][Full Text] [Related]
12. Usefulness of an Additional Filter Created Using 3D Printing for Whole-Body X-ray Imaging with a Long-Length Detector.
Seo H; Kim W; Han B; Jang H; Yoon MS; Lee Y
Sensors (Basel); 2022 Jun; 22(11):. PubMed ID: 35684921
[TBL] [Abstract][Full Text] [Related]
13. Comparative evaluation of newly developed model-based and commercially available hybrid-type iterative reconstruction methods and filter back projection method in terms of accuracy of computer-aided volumetry (CADv) for low-dose CT protocols in phantom study.
Ohno Y; Yaguchi A; Okazaki T; Aoyagi K; Yamagata H; Sugihara N; Koyama H; Yoshikawa T; Sugimura K
Eur J Radiol; 2016 Aug; 85(8):1375-82. PubMed ID: 27423675
[TBL] [Abstract][Full Text] [Related]
14. Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system.
Moore CS; Beavis AW; Saunderson JR
Br J Radiol; 2008 Oct; 81(970):771-7. PubMed ID: 18662964
[TBL] [Abstract][Full Text] [Related]
15. Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study.
Thompson JD; Chakraborty DP; Szczepura K; Tootell AK; Vamvakas I; Manning DJ; Hogg P
Med Phys; 2016 Mar; 43(3):1265-74. PubMed ID: 26936711
[TBL] [Abstract][Full Text] [Related]
16. Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.
Kimme-Smith C; Aberle DR; Sayre JW; Hart EM; Greaves SM; Brown K; Young DA; Deseran MD; Johnson T; Johnson SL
AJR Am J Roentgenol; 1995 Aug; 165(2):269-73. PubMed ID: 7618538
[TBL] [Abstract][Full Text] [Related]
17. Pediatric thoracic CT angiography at 70 kV: a phantom study to investigate the effects on image quality and radiation dose.
MacDougall RD; Kleinman PL; Yu L; Lee EY
Pediatr Radiol; 2016 Jul; 46(8):1114-9. PubMed ID: 26987734
[TBL] [Abstract][Full Text] [Related]
18. Dose optimization in pediatric cardiac x-ray imaging.
Gislason AJ; Davies AG; Cowen AR
Med Phys; 2010 Oct; 37(10):5258-69. PubMed ID: 21089760
[TBL] [Abstract][Full Text] [Related]
19. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.
Kim H; Park CM; Song YS; Lee SM; Goo JM
Eur J Radiol; 2014 May; 83(5):848-57. PubMed ID: 24572380
[TBL] [Abstract][Full Text] [Related]
20. Pulmonary nodules with ground-glass opacity can be reliably measured with low-dose techniques regardless of iterative reconstruction: results of a phantom study.
Siegelman JW; Supanich MP; Gavrielides MA
AJR Am J Roentgenol; 2015 Jun; 204(6):1242-7. PubMed ID: 26001234
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]