These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
173 related articles for article (PubMed ID: 31168378)
1. Anatomical predictors of conduction damage after transcatheter implantation of the aortic valve. Tretter JT; Mori S; Anderson RH; Taylor MD; Ollberding N; Truong V; Choo J; Kereiakes D; Mazur W Open Heart; 2019; 6(1):e000972. PubMed ID: 31168378 [TBL] [Abstract][Full Text] [Related]
2. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation. van der Boon RM; Houthuizen P; Urena M; Poels TT; van Mieghem NM; Brueren GR; Altintas S; Nuis RJ; Serruys PW; van Garsse LA; van Domburg RT; Cabau JR; de Jaegere PP; Prinzen FW Catheter Cardiovasc Interv; 2015 Apr; 85(5):E144-52. PubMed ID: 25504891 [TBL] [Abstract][Full Text] [Related]
3. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience. Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074 [TBL] [Abstract][Full Text] [Related]
4. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience. Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846 [TBL] [Abstract][Full Text] [Related]
9. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve. Urena M; Mok M; Serra V; Dumont E; Nombela-Franco L; DeLarochellière R; Doyle D; Igual A; Larose E; Amat-Santos I; Côté M; Cuéllar H; Pibarot P; de Jaegere P; Philippon F; Garcia del Blanco B; Rodés-Cabau J J Am Coll Cardiol; 2012 Oct; 60(18):1743-52. PubMed ID: 23040577 [TBL] [Abstract][Full Text] [Related]
10. Novel Anatomic Predictors of New Persistent Left Bundle Branch Block After Evolut Transcatheter Aortic Valve Implantation. Zaid S; Sengupta A; Okoli K; Tsoi M; Khan A; Ahmad H; Goldberg JB; Undemir C; Rozenshtein A; Patel N; Khan M; Gupta E; Kovacic J; Lansman SL; Dangas GD; Sharma SK; Kini A; Tang GHL Am J Cardiol; 2020 Apr; 125(8):1222-1229. PubMed ID: 32093955 [TBL] [Abstract][Full Text] [Related]
11. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation. Hamdan A; Guetta V; Klempfner R; Konen E; Raanani E; Glikson M; Goitein O; Segev A; Barbash I; Fefer P; Spiegelstein D; Goldenberg I; Schwammenthal E JACC Cardiovasc Interv; 2015 Aug; 8(9):1218-1228. PubMed ID: 26292585 [TBL] [Abstract][Full Text] [Related]
12. Left Bundle Branch Block after Transcatheter Aortic Valve Implantation with Edwards Sapien 3 Valve: Influence of the Valve Depth Implantation. Unzué L; García E; Díaz-Antón B; Rodríguez-Rodrigo FJ; Rodríguez Del Río M; Teijeiro R; Medina J; Parra FJ Cardiovasc Revasc Med; 2019 Nov; 20(11):949-955. PubMed ID: 30745060 [TBL] [Abstract][Full Text] [Related]
13. Clinical Impact of New-Onset Left Bundle-Branch Block After Transcatheter Aortic Valve Implantation in the Japanese Population - A Single High-Volume Center Experience. Sasaki K; Izumo M; Kuwata S; Ishibashi Y; Kamijima R; Watanabe M; Kaihara T; Okuyama K; Koga M; Nishikawa H; Tanabe Y; Higuma T; Akashi YJ Circ J; 2020 May; 84(6):1012-1019. PubMed ID: 32224577 [TBL] [Abstract][Full Text] [Related]
14. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve. Franzoni I; Latib A; Maisano F; Costopoulos C; Testa L; Figini F; Giannini F; Basavarajaiah S; Mussardo M; Slavich M; Taramasso M; Cioni M; Longoni M; Ferrarello S; Radinovic A; Sala S; Ajello S; Sticchi A; Giglio M; Agricola E; Chieffo A; Montorfano M; Alfieri O; Colombo A Am J Cardiol; 2013 Aug; 112(4):554-9. PubMed ID: 23726173 [TBL] [Abstract][Full Text] [Related]
15. One-Year Follow-Up of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the SAPIEN 3 Valve. Dolci G; Vollema EM; van der Kley F; de Weger A; Ajmone Marsan N; Delgado V; Bax JJ Am J Cardiol; 2019 Oct; 124(8):1239-1245. PubMed ID: 31439281 [TBL] [Abstract][Full Text] [Related]
16. [Transcatheter aortic valve implantation and conduction disturbances]. Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339 [TBL] [Abstract][Full Text] [Related]
17. Relationship between the membranous septum and the virtual basal ring of the aortic root in candidates for transcatheter implantation of the aortic valve. Mori S; Tretter JT; Toba T; Izawa Y; Tahara N; Nishii T; Shimoyama S; Tanaka H; Shinke T; Hirata KI; Spicer DE; Saremi F; Anderson RH Clin Anat; 2018 May; 31(4):525-534. PubMed ID: 29542191 [TBL] [Abstract][Full Text] [Related]
18. Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation. Aktug Ö; Dohmen G; Brehmer K; Koos R; Altiok E; Deserno V; Herpertz R; Autschbach R; Marx N; Hoffmann R Int J Cardiol; 2012 Sep; 160(1):26-30. PubMed ID: 21458085 [TBL] [Abstract][Full Text] [Related]
19. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis. Droppa M; Rudolph TK; Baan J; Nielsen NE; Baumgartner H; Vendrik J; Froehlich M; Borst O; Wöhrle J; Gawaz M; Potratz P; Hack LP; Mauri V; Baranowski J; Bramlage P; Kurucova J; Thoenes M; Rottbauer W; Geisler T Heart Vessels; 2020 Dec; 35(12):1735-1745. PubMed ID: 32591894 [TBL] [Abstract][Full Text] [Related]
20. Impact of New-Onset Left Bundle Branch Block and Periprocedural Permanent Pacemaker Implantation on Clinical Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis. Regueiro A; Abdul-Jawad Altisent O; Del Trigo M; Campelo-Parada F; Puri R; Urena M; Philippon F; Rodés-Cabau J Circ Cardiovasc Interv; 2016 May; 9(5):e003635. PubMed ID: 27169577 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]