These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
418 related articles for article (PubMed ID: 31171424)
1. Comparison between navigated reported position and postoperative computed tomography to evaluate accuracy in a robotic navigation system in total knee arthroplasty. Figueroa F; Wakelin E; Twiggs J; Fritsch B Knee; 2019 Aug; 26(4):869-875. PubMed ID: 31171424 [TBL] [Abstract][Full Text] [Related]
2. Alignment accuracy and functional outcomes between hand-held navigation and conventional instruments in TKA: a randomized controlled trial. Narkbunnam R; Pornrattanamaneewong C; Ruangsomboon P; Chareancholvanich K BMC Musculoskelet Disord; 2022 Nov; 23(1):1017. PubMed ID: 36435760 [TBL] [Abstract][Full Text] [Related]
3. The accelerometer-based navigation system demonstrated superior radiological outcomes in restoring mechanical alignment and component sagittal positioning in total knee arthroplasty. Gao J; Hou Y; Li R; Ke Y; Li Z; Lin J BMC Musculoskelet Disord; 2021 Apr; 22(1):351. PubMed ID: 33849489 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis. Miyasaka T; Kurosaka D; Saito M; Omori T; Ikeda R; Marumo K J Arthroplasty; 2017 Jan; 32(1):47-52. PubMed ID: 27369304 [TBL] [Abstract][Full Text] [Related]
5. [Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases]. Galaud B; Beaufils P; Michaut M; Abadie P; Fallet L; Boisrenoult P Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):573-9. PubMed ID: 18929752 [TBL] [Abstract][Full Text] [Related]
6. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661 [TBL] [Abstract][Full Text] [Related]
7. An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements. Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1580-1586. PubMed ID: 30066018 [TBL] [Abstract][Full Text] [Related]
8. Navigated Unicompartmental Knee Arthroplasty: A Different Perspective. Malhotra R; Gupta S; Gupta V; Manhas V Clin Orthop Surg; 2021 Dec; 13(4):491-498. PubMed ID: 34868498 [TBL] [Abstract][Full Text] [Related]
9. [Early effectiveness of computer navigation-assisted total knee arthroplasty]. Sun H; Zheng K; Zhang W; Li N; Zhang L; Zhou J; Xu Y; Li R Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Oct; 35(10):1273-1280. PubMed ID: 34651480 [TBL] [Abstract][Full Text] [Related]
10. Coronal Correction for Severe Deformity Using Robotic-Assisted Total Knee Arthroplasty. Marchand RC; Sodhi N; Khlopas A; Sultan AA; Higuera CA; Stearns KL; Mont MA J Knee Surg; 2018 Jan; 31(1):2-5. PubMed ID: 29179223 [TBL] [Abstract][Full Text] [Related]
11. Postoperative full leg radiographs exhibit less residual coronal varus deformity compared to intraoperative measurements in robotic arm-assisted total knee arthroplasty with the MAKO™ system. Glowalla C; Langer S; Lenze U; Lazic I; Hirschmann MT; Hinterwimmer F; von Eisenhart-Rothe R; Pohlig F Knee Surg Sports Traumatol Arthrosc; 2023 Sep; 31(9):3912-3918. PubMed ID: 36964782 [TBL] [Abstract][Full Text] [Related]
12. Total Knee Arthroplasty in Patients With Extra-Articular Deformity: Restoration of Mechanical Alignment Using Accelerometer-Based Navigation System. Matassi F; Cozzi Lepri A; Innocenti M; Zanna L; Civinini R; Innocenti M J Arthroplasty; 2019 Apr; 34(4):676-681. PubMed ID: 30685259 [TBL] [Abstract][Full Text] [Related]
13. Comparison of CT with intra-operative navigation reported implant position utilising a robotic assisted technique in total knee arthroplasty. Sharma N; Berera V; Petterwood J Med Eng Phys; 2022 Oct; 108():103881. PubMed ID: 36195366 [TBL] [Abstract][Full Text] [Related]
15. Robotic-assisted total knee arthroplasty is more advantageous for knees with severe deformity: a randomized controlled trial study design. Tian R; Duan X; Kong N; Li X; Wang J; Tian H; Shi Z; Yan S; Lyu J; Wang K; Yang P Int J Surg; 2023 Mar; 109(3):287-296. PubMed ID: 36927832 [TBL] [Abstract][Full Text] [Related]
16. [Value of personalized extramedullary positioning technique on tibia side for coronal alignment of tibial prosthesis in total knee arthroplasty]. Xiong C; Li P; Zhang Y; Du Y; Li T; Gao Z; Zhou Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Feb; 36(2):177-182. PubMed ID: 35172402 [TBL] [Abstract][Full Text] [Related]
17. Radiographic outcomes in the coronal plane with iASSIST™ versus optical navigation for total knee arthroplasty: A preliminary case-control study. Desseaux A; Graf P; Dubrana F; Marino R; Clavé A Orthop Traumatol Surg Res; 2016 May; 102(3):363-8. PubMed ID: 27033838 [TBL] [Abstract][Full Text] [Related]
18. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT. Slevin O; Hirschmann A; Schiapparelli FF; Amsler F; Huegli RW; Hirschmann MT Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1602-1609. PubMed ID: 29026941 [TBL] [Abstract][Full Text] [Related]
19. Postoperative radiologic outcome comparison between conventional and computer-assisted navigation total knee arthroplasty in extra-articular tibia vara. Cho Y; Shin HK; Kim E; Park JH; Park SJ; Jang T; Jeong HJ J Orthop Surg (Hong Kong); 2020; 28(1):2309499020905702. PubMed ID: 32114895 [TBL] [Abstract][Full Text] [Related]
20. Acquisition of coronal alignment according to the degree of varus deformity in total knee arthroplasty using computer-assisted navigation. Song SK; Cho MR; Lee SH; Kim HC; Kang DW; Choi WK J Orthop Surg (Hong Kong); 2020; 28(2):2309499020926268. PubMed ID: 32468906 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]