BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 31171893)

  • 21. Acoustic radiation force impulse imaging (ARFI) for non-invasive detection of liver fibrosis: examination standards and evaluation of interlobe differences in healthy subjects and chronic liver disease.
    Karlas T; Pfrepper C; Wiegand J; Wittekind C; Neuschulz M; Mössner J; Berg T; Tröltzsch M; Keim V
    Scand J Gastroenterol; 2011 Dec; 46(12):1458-67. PubMed ID: 21916815
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Point Shear Wave Elastography for Assessing Liver Stiffness in Chronic Liver Diseases of Different Etiologies Compared to Biopsy.
    Saadi T; Khoury J; Toukan W; Krimasky R; Veitsman E; Baruch Y; Gaitini D; Beck-Razi N
    Isr Med Assoc J; 2021 Apr; 23(4):223-228. PubMed ID: 33899354
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analysis of Point Shear Wave Elastography and Biochemical Markers for the Detection of Liver Fibrosis.
    Cebula M; Gruszczyńska K; Hartleb M; Baron J
    Medicina (Kaunas); 2021 Jan; 57(1):. PubMed ID: 33418917
    [No Abstract]   [Full Text] [Related]  

  • 24. Assessment of liver fibrosis with 2-D shear wave elastography in comparison to transient elastography and acoustic radiation force impulse imaging in patients with chronic liver disease.
    Gerber L; Kasper D; Fitting D; Knop V; Vermehren A; Sprinzl K; Hansmann ML; Herrmann E; Bojunga J; Albert J; Sarrazin C; Zeuzem S; Friedrich-Rust M
    Ultrasound Med Biol; 2015 Sep; 41(9):2350-9. PubMed ID: 26116161
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Liver ultrasound elastography for the evaluation of periportal fibrosis in schistosomiasis mansoni: A cross-sectional study.
    Carvalho Santos J; Dória Batista A; Maria Mola Vasconcelos C; Souza Lemos R; Romão de Souza Junior V; Dessein A; Dessein H; Maria Lucena Montenegro S; Pessoa Almeida Lopes E; Lúcia Coutinho Domingues A
    PLoS Negl Trop Dis; 2018 Nov; 12(11):e0006868. PubMed ID: 30444885
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Liver and Spleen Stiffness Measurements by Point Shear Wave Elastography via Acoustic Radiation Force Impulse: Intraobserver and Interobserver Variability and Predictors of Variability in a US Population.
    Balakrishnan M; Souza F; Muñoz C; Augustin S; Loo N; Deng Y; Ciarleglio M; Garcia-Tsao G
    J Ultrasound Med; 2016 Nov; 35(11):2373-2380. PubMed ID: 27663656
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Added value of point shear-wave elastography in the diagnosis of acute cholecystitis.
    Kim JE; Choi DS; Bae K; Cho JM; Jeong CY; Kim HO
    Eur Radiol; 2017 Apr; 27(4):1517-1526. PubMed ID: 27510624
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Image-guided point-shear-wave elastography: a valid and reliable technique for liver fibrotic staging.
    Bergsma S; van Gent M; Dam-Vervloet AJ; Lagerweij MCM; van der Wouden EJ; Nijholt IM; Boomsma MF; Poot L
    J Ultrasound; 2024 Jun; 27(2):323-328. PubMed ID: 38281292
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography.
    Deffieux T; Gennisson JL; Bousquet L; Corouge M; Cosconea S; Amroun D; Tripon S; Terris B; Mallet V; Sogni P; Tanter M; Pol S
    J Hepatol; 2015 Feb; 62(2):317-24. PubMed ID: 25251998
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Performance of two--dimensional ultrasound shear wave elastography: reference values of normal liver stiffness in children.
    Galina P; Alexopoulou E; Zellos A; Grigoraki V; Siahanidou T; Kelekis NL; Zarifi M
    Pediatr Radiol; 2019 Jan; 49(1):91-98. PubMed ID: 30267166
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intra- and inter-operator reproducibility of US point shear-wave elastography in various organs: evaluation in phantoms and healthy volunteers.
    Kishimoto R; Kikuchi K; Koyama A; Kershaw J; Omatsu T; Tachibana Y; Suga M; Obata T
    Eur Radiol; 2019 Nov; 29(11):5999-6008. PubMed ID: 31089847
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ultrasound shear wave speed measurements correlate with liver fibrosis in children.
    Dillman JR; Heider A; Bilhartz JL; Smith EA; Keshavarzi N; Rubin JM; Lopez MJ
    Pediatr Radiol; 2015 Sep; 45(10):1480-8. PubMed ID: 25851300
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Factors that influence kidney shear wave speed assessed by acoustic radiation force impulse elastography in patients without kidney pathology.
    Bota S; Bob F; Sporea I; Şirli R; Popescu A
    Ultrasound Med Biol; 2015 Jan; 41(1):1-6. PubMed ID: 25438855
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Relationship between the estimated glomerular filtration rate and kidney shear wave speed values assessed by acoustic radiation force impulse elastography: a pilot study.
    Bob F; Bota S; Sporea I; Sirli R; Popescu A; Schiller A
    J Ultrasound Med; 2015 Apr; 34(4):649-54. PubMed ID: 25792580
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Point Shear Wave Elastography in Assessment of Hepatic Fibrosis: Diagnostic Accuracy in Subjects With Native and Transplanted Livers Referred for Percutaneous Biopsy.
    Perry MT; Savjani N; Bluth EI; Dornelles A; Therapondos G
    Ultrasound Q; 2016 Sep; 32(3):201-7. PubMed ID: 26808171
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Shear wave elastography and transient elastography in HCV patients after direct-acting antivirals.
    Argalia G; Tarantino G; Ventura C; Campioni D; Tagliati C; Guardati P; Kostandini A; Marzioni M; Giuseppetti GM; Giovagnoni A
    Radiol Med; 2021 Jun; 126(6):894-899. PubMed ID: 33492651
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reliability of performing ultrasound derived SWE and fat fraction in adult livers.
    Gao J; Wong C; Maar M; Park D
    Clin Imaging; 2021 Dec; 80():424-429. PubMed ID: 34543866
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination and prospective validation of cut-off values for the diagnosis of liver cirrhosis for point shear-wave elastography/acoustic radiation force impulse imaging using the ACUSON Sequoia ultrasound system.
    Meitner-Schellhaas B; Schüler S; Vogl T; Jesper D; Vetter M; Waldner M; Strobel D
    Eur J Gastroenterol Hepatol; 2024 Jan; 36(1):135-140. PubMed ID: 37994620
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction.
    Kennedy P; Bane O; Hectors SJ; Gordic S; Berger M; Delaney V; Salem F; Lewis S; Menon M; Taouli B
    Eur J Radiol; 2020 May; 126():108949. PubMed ID: 32179424
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Utility of point shear wave elastography in characterisation of focal liver lesions.
    Hasab Allah M; Salama RM; Marie MS; Mandur AA; Omar H
    Expert Rev Gastroenterol Hepatol; 2018 Feb; 12(2):201-207. PubMed ID: 29219625
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.