These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

383 related articles for article (PubMed ID: 31174357)

  • 21. Cuffless blood-pressure estimation method using a heart-rate variability-derived parameter.
    Chen Y; Shi S; Liu YK; Huang SL; Ma T
    Physiol Meas; 2018 Sep; 39(9):095002. PubMed ID: 30089101
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Non-Invasive Blood Pressure Sensing via Machine Learning.
    Attivissimo F; D'Alessandro VI; De Palma L; Lanzolla AML; Di Nisio A
    Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837172
    [TBL] [Abstract][Full Text] [Related]  

  • 23. New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy.
    Lin WH; Wang H; Samuel OW; Liu G; Huang Z; Li G
    Physiol Meas; 2018 Feb; 39(2):025005. PubMed ID: 29319536
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography.
    Zhang Y; Ren X; Liang X; Ye X; Zhou C
    IEEE J Biomed Health Inform; 2022 Dec; 26(12):5907-5917. PubMed ID: 36103444
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Causal inference based cuffless blood pressure estimation: A pilot study.
    Liu L; Zhang YT; Wang W; Chen Y; Ding X
    Comput Biol Med; 2023 Jun; 159():106900. PubMed ID: 37087777
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation.
    Ding X; Zhang Y; Tsang HK
    Physiol Meas; 2016 Feb; 37(2):227-37. PubMed ID: 26767518
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Multi-Sensor Fusion Approach for Cuff-Less Blood Pressure Measurement.
    Miao F; Liu ZD; Liu JK; Wen B; He QY; Li Y
    IEEE J Biomed Health Inform; 2020 Jan; 24(1):79-91. PubMed ID: 30892255
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Photoplethysmography derivatives and pulse transit time in overnight blood pressure monitoring.
    Shahrbabaki SS; Ahmed B; Penzel T; Cvetkovic D
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():2855-2858. PubMed ID: 28268912
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Non-invasive blood pressure estimation combining deep neural networks with pre-training and partial fine-tuning.
    Meng Z; Yang X; Liu X; Wang D; Han X
    Physiol Meas; 2022 Nov; 43(11):. PubMed ID: 36301705
    [No Abstract]   [Full Text] [Related]  

  • 30. Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio.
    Gholamhosseini H; Baig M; Rastegar S; Lindén M
    Stud Health Technol Inform; 2018; 249():77-83. PubMed ID: 29866960
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation.
    Lee J; Sohn J; Park J; Yang S; Lee S; Kim HC
    Biomed Eng Online; 2018 Jun; 17(1):81. PubMed ID: 29914491
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Novel blood pressure estimation method using single photoplethysmography feature.
    Yang Chen ; Shuo Cheng ; Tong Wang ; Ting Ma
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():1712-1715. PubMed ID: 29060216
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of cuff-based and cuffless continuous blood pressure measurements in children and adolescents.
    Zachwieja J; Neyman-Bartkowiak A; Rabiega A; Wojciechowska M; Barabasz M; Musielak A; Silska-Dittmar M; Ostalska-Nowicka D
    Clin Exp Hypertens; 2020 Aug; 42(6):512-518. PubMed ID: 31941385
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Continuous cuffless and non-invasive measurement of arterial blood pressure-concepts and future perspectives.
    Pilz N; Patzak A; Bothe TL
    Blood Press; 2022 Dec; 31(1):254-269. PubMed ID: 36184775
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Continuous non-invasive determination of nocturnal blood pressure variation using photoplethysmographic pulse wave signals: comparison of pulse propagation time, pulse transit time and RR-interval.
    Fischer C; Penzel T
    Physiol Meas; 2019 Jan; 40(1):014001. PubMed ID: 30523856
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Using a new PPG indicator to increase the accuracy of PTT-based continuous cuffless blood pressure estimation.
    Wan-Hua Lin ; Hui Wang ; Samuel OW; Guanglin Li
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():738-741. PubMed ID: 29059978
    [TBL] [Abstract][Full Text] [Related]  

  • 37. DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography.
    Kim DK; Kim YT; Kim H; Kim DJ
    IEEE J Biomed Health Inform; 2022 Aug; 26(8):3697-3707. PubMed ID: 35511844
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics.
    Liu J; Yan BP; Zhang YT; Ding XR; Su P; Zhao N
    IEEE Trans Biomed Eng; 2019 Jun; 66(6):1514-1525. PubMed ID: 30307851
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques.
    Miao F; Wen B; Hu Z; Fortino G; Wang XP; Liu ZD; Tang M; Li Y
    Artif Intell Med; 2020 Aug; 108():101919. PubMed ID: 32972654
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A feature exploration methodology for learning based cuffless blood pressure measurement using photoplethysmography.
    Kefeng Duan ; Zhiliang Qian ; Atef M; Guoxing Wang
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():6385-6388. PubMed ID: 28269709
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.