These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
126 related articles for article (PubMed ID: 31177842)
1. Undersizing the Exeter stem in hip hemiarthroplasty increases the risk of periprosthetic fracture. Korsnes L; Gottvall A; Buttazzoni C; Mints M Hip Int; 2020 Jul; 30(4):469-473. PubMed ID: 31177842 [TBL] [Abstract][Full Text] [Related]
2. Higher periprosthetic fracture rate associated with use of modern uncemented stems compared to cemented stems in femoral neck fractures. Song JSA; Dillman D; Wilson D; Dunbar M; Richardson G Hip Int; 2019 Mar; 29(2):177-183. PubMed ID: 29682992 [TBL] [Abstract][Full Text] [Related]
3. More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures: a study from the Norwegian Hip Fracture Register 2005 to 2016. Kristensen TB; Dybvik E; Furnes O; Engesæter LB; Gjertsen JE Bone Joint J; 2018 Dec; 100-B(12):1565-1571. PubMed ID: 30499310 [TBL] [Abstract][Full Text] [Related]
4. Periprosthetic fracture in the elderly with anatomic modular cementless hemiarthroplasty. Kouyoumdjian P; Dhenin A; Dupeyron A; Coulomb R; Asencio G Orthop Traumatol Surg Res; 2016 Oct; 102(6):701-5. PubMed ID: 27496660 [TBL] [Abstract][Full Text] [Related]
5. Increased risk for postoperative periprosthetic fracture in hip fracture patients with the Exeter stem than the anatomic SP2 Lubinus stem. Mellner C; Mohammed J; Larsson M; Esberg S; Szymanski M; Hellström N; Chang C; Berg HE; Sköldenberg O; Knutsson B; Morberg P; Mukka S Eur J Trauma Emerg Surg; 2021 Jun; 47(3):803-809. PubMed ID: 31740996 [TBL] [Abstract][Full Text] [Related]
6. Radiological subsidence and acetabular erosion after tapered uncemented hemiarthroplasty in femoral neck fractures a 10- to 13- year follow-up study. Rubio I; Bellostas L; García-Rey E Injury; 2020 Apr; 51 Suppl 1():S37-S41. PubMed ID: 32067774 [TBL] [Abstract][Full Text] [Related]
7. Incidence of periprosthetic fractures after hip hemiarthroplasty: Are uncemented prostheses unsafe? McGraw IW; Spence SC; Baird EJ; Eckhardt SM; Ayana GE Injury; 2013 Dec; 44(12):1945-8. PubMed ID: 24001784 [TBL] [Abstract][Full Text] [Related]
9. Cementless, Fluted, Long-Stem Hemiarthroplasty for Vancouver B2 and B3 Periprosthetic Fractures Around Hip Hemiarthroplasty. Lizaur-Utrilla A; Gonzalez-Parreño S; Miralles-Muñoz FA; Lopez-Prats FA J Arthroplasty; 2019 Jun; 34(6):1179-1183. PubMed ID: 30879875 [TBL] [Abstract][Full Text] [Related]
10. Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years. Mohammed J; Mukka S; Hedbeck CJ; Chammout G; Gordon M; Sköldenberg O Acta Orthop; 2019 Oct; 90(5):427-432. PubMed ID: 31154885 [TBL] [Abstract][Full Text] [Related]
11. Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures: 5-year followup of a randomized trial. Langslet E; Frihagen F; Opland V; Madsen JE; Nordsletten L; Figved W Clin Orthop Relat Res; 2014 Apr; 472(4):1291-9. PubMed ID: 24081667 [TBL] [Abstract][Full Text] [Related]
12. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem. Brodén C; Mukka S; Muren O; Eisler T; Boden H; Stark A; Sköldenberg O Acta Orthop; 2015 Apr; 86(2):169-74. PubMed ID: 25280133 [TBL] [Abstract][Full Text] [Related]
13. Hemiarthroplasty using cemented or uncemented stems of proven design: a comparative study. Grammatopoulos G; Wilson HA; Kendrick BJ; Pulford EC; Lippett J; Deakin M; Andrade AJ; Kambouroglou G Bone Joint J; 2015 Jan; 97-B(1):94-9. PubMed ID: 25568420 [TBL] [Abstract][Full Text] [Related]
15. Implant-related complications following hip hemiarthroplasty: a comparison of modern cemented and uncemented prostheses. Morris K; Davies H; Wronka K Eur J Orthop Surg Traumatol; 2015 Oct; 25(7):1161-4. PubMed ID: 26174416 [TBL] [Abstract][Full Text] [Related]
16. Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up. Scott T; Salvatore A; Woo P; Lee YY; Salvati EA; Gonzalez Della Valle A J Arthroplasty; 2018 Apr; 33(4):1120-1125. PubMed ID: 29223405 [TBL] [Abstract][Full Text] [Related]
17. Subsidence and perioperative periprosthetic fractures using collarless hydroxyapatite-coated stem for displaced femoral neck fractures according to Dorr type. Song JH; Jo WL; Lee KH; Cho YJ; Park J; Oh S J Orthop Surg (Hong Kong); 2019; 27(3):2309499019877530. PubMed ID: 31578134 [TBL] [Abstract][Full Text] [Related]
18. Implant and patient survival rates using Exeter Trauma Stem hemiarthroplasty in fracture neck of femur patients: The largest study to date. Hammouche SA; Phillips J; Massoumi A; Scammell BE; Moran CG Injury; 2022 Jun; 53(6):2199-2206. PubMed ID: 35393097 [TBL] [Abstract][Full Text] [Related]
19. Perioperative Periprosthetic Femur Fractures are Strongly Correlated With Fixation Method: an Analysis From the American Joint Replacement Registry. Springer BD; Etkin CD; Shores PB; Gioe TJ; Lewallen DG; Bozic KJ J Arthroplasty; 2019 Jul; 34(7S):S352-S354. PubMed ID: 30852066 [TBL] [Abstract][Full Text] [Related]
20. Postoperative periprosthetic fractures in patients with an Exeter stem due to a femoral neck fracture: cumulative incidence and surgical outcome. Inngul C; Enocson A Int Orthop; 2015 Sep; 39(9):1683-8. PubMed ID: 25341951 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]