BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

624 related articles for article (PubMed ID: 31178147)

  • 1. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures.
    Sohn HS; Shin SJ
    Injury; 2019 Jul; 50(7):1300-1305. PubMed ID: 31178147
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures.
    Shin SJ; Kwak JW; Sohn HS
    Int Orthop; 2022 Sep; 46(9):2119-2126. PubMed ID: 35575805
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.
    Zhao W; Qu W; Fu C; Jiang H; Liu S; Cheng C
    Int Orthop; 2017 Sep; 41(9):1757-1762. PubMed ID: 28577034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.
    Chang H; Yao ZL; Hou YL; Cao Y; Guo XH; Li GJ; Yu B
    Orthop Surg; 2018 Aug; 10(3):218-226. PubMed ID: 30152611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single locking compression plate fixation of extra-articular distal humeral fractures.
    Kumar MN; Ravishankar MR; Manur R
    J Orthop Traumatol; 2015 Jun; 16(2):99-104. PubMed ID: 25326853
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fractures of the distal humerus operated on using the Lambda® plate: report of 75 cases at 9.5 years follow-up.
    Saragaglia D; Rouchy RC; Mercier N
    Orthop Traumatol Surg Res; 2013 Oct; 99(6):707-12. PubMed ID: 24029585
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical result of plate osteosynthesis using a locking plate system through an anterior humeral approach for distal shaft fracture of the humerus that occurred during a throwing motion.
    Kim SJ; Lee SH; Son H; Lee BG
    Int Orthop; 2016 Jul; 40(7):1489-94. PubMed ID: 26202018
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modified anterolateral approach for internal fixation of Holstein-Lewis humeral shaft fractures.
    Lee HM; Kim YS; Kang S; Lee MY; Kim JP
    J Orthop Sci; 2018 Jan; 23(1):137-143. PubMed ID: 29103824
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus.
    Spitzer AB; Davidovitch RI; Egol KA
    Injury; 2009 Mar; 40(3):240-4. PubMed ID: 19195653
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of Fixation for Distal Humeral Diaphyseal Fracture by Locking Compression Plate.
    Saha MK; Islam SS; Alam S; Rahman MW; Kamruzzaman M; Paul J; Rahman MM; Alamgir MK
    Mymensingh Med J; 2019 Jan; 28(1):60-69. PubMed ID: 30755552
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures.
    Jitprapaikulsarn S; Neti N; Thremthakanpon W; Gromprasit A
    Eur J Orthop Surg Traumatol; 2020 Dec; 30(8):1515-1521. PubMed ID: 32468266
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anteromedial minimally invasive plate osteosynthesis (MIPO) for distal third humeral shaft fractures - Is it possible?: A cadaveric study.
    Buranaphatthana T; Apivatthakakul T; Apivatthakakul V
    Injury; 2019 Jun; 50(6):1166-1174. PubMed ID: 31072594
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures.
    Lim JR; Yoon TH; Choi YR; Lee HM; Chun YM
    J Orthop Res; 2021 Sep; 39(9):1877-1883. PubMed ID: 33222233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dual plate fixation on distal third diaphyseal fracture of the humerus.
    Lee JK; Choi YS; Sim YS; Choi DS; Han SH
    Int Orthop; 2017 Aug; 41(8):1655-1661. PubMed ID: 27909754
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Lateral minimally invasive plate osteosynthesis (MIPO) with long PHILOS for proximal metaphyseal-diaphyseal humeral fracture: surgical techniques and a clinical series.
    Jiamton C; Rungchamrussopa P; Taweekitikul P; Leelasestaporn T; Anantasinkul P; Apivatthakakul T
    Eur J Orthop Surg Traumatol; 2024 Jan; 34(1):689-697. PubMed ID: 37688639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. AO extra-articular distal humerus locking plate: extended spectrum of usage in intra-articular distal fractures with metaphyseal extension--our experience with 20 cases.
    Aggarwal S; Kumar V; Bhagwat KR; Behera P
    Eur J Orthop Surg Traumatol; 2014 May; 24(4):505-11. PubMed ID: 23563623
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
    Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
    Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.