These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 31183460)
1. The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions. Radice S; Yao J; Babauta J; Laurent MP; Wimmer MA Materialia (Oxf); 2019 Jun; 6():. PubMed ID: 31183460 [TBL] [Abstract][Full Text] [Related]
2. Effects of bovine serum albumin and hyaluronic acid on the electrochemical response of a CoCrMo alloy to cathodic and anodic excursions. Radice S; Liu S; Pourzal R; Laurent MP; Wimmer MA J Bio Tribocorros; 2019 Dec; 5(4):. PubMed ID: 31828005 [TBL] [Abstract][Full Text] [Related]
3. The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy. Liu Y; Gilbert JL J Biomed Mater Res B Appl Biomater; 2018 Jan; 106(1):209-220. PubMed ID: 28117942 [TBL] [Abstract][Full Text] [Related]
5. In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids. Igual Munoz A; Schwiesau J; Jolles BM; Mischler S Acta Biomater; 2015 Jul; 21():228-36. PubMed ID: 25797841 [TBL] [Abstract][Full Text] [Related]
6. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation. Royhman D; Radhakrishnan R; Yuan JC; Mathew MT; Mercuri LG; Sukotjo C J Craniomaxillofac Surg; 2014 Oct; 42(7):1052-61. PubMed ID: 24548869 [TBL] [Abstract][Full Text] [Related]
8. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation. Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125 [TBL] [Abstract][Full Text] [Related]
9. The effect of the inflammatory species hypochlorous acid on the corrosion and surface damage of Ti-6Al-4V and CoCrMo alloys. Kubacki GW; Gilbert JL J Biomed Mater Res A; 2018 Dec; 106(12):3185-3194. PubMed ID: 30151943 [TBL] [Abstract][Full Text] [Related]
10. Synthetic periprosthetic synovial fluid development for in vitro cell-tribocorrosion testing using the Taguchi array approach. Wiegand MJ; Khullar P; Mercuri JJ; Gilbert JL J Biomed Mater Res A; 2021 Apr; 109(4):551-561. PubMed ID: 32946189 [TBL] [Abstract][Full Text] [Related]
11. Corrosion resistance of the nickel-free high-nitrogen steel FeCrMnMoN0.9 under simulated inflammatory conditions. Radice S; Impergre A; Fischer A; Wimmer MA J Biomed Mater Res B Appl Biomater; 2021 Jun; 109(6):902-910. PubMed ID: 33159504 [TBL] [Abstract][Full Text] [Related]
12. Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. Gilbert JL; Sivan S; Liu Y; Kocagöz SB; Arnholt CM; Kurtz SM J Biomed Mater Res A; 2015 Jan; 103(1):211-23. PubMed ID: 24619511 [TBL] [Abstract][Full Text] [Related]
13. Hyaluronic acid stimulates the formation of calcium phosphate on CoCrMo alloy in simulated physiological solution. Milošev I; Hmeljak J; Cör A J Mater Sci Mater Med; 2013 Mar; 24(3):555-71. PubMed ID: 23250579 [TBL] [Abstract][Full Text] [Related]
14. Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy. Wiegand MJ; Shenoy AA; Littlejohn SE; Gilbert JL ACS Biomater Sci Eng; 2020 Mar; 6(3):1344-1354. PubMed ID: 33455367 [TBL] [Abstract][Full Text] [Related]
15. Tribocorrosion of a CoCrMo alloy sliding against articular cartilage and the impact of metal ion release on chondrocytes. Stojanović B; Bauer C; Stotter C; Klestil T; Nehrer S; Franek F; Rodríguez Ripoll M Acta Biomater; 2019 Aug; 94():597-609. PubMed ID: 31226479 [TBL] [Abstract][Full Text] [Related]
16. Influence of carbides and microstructure of CoCrMo alloys on their metallic dissolution resistance. Valero-Vidal C; Casabán-Julián L; Herraiz-Cardona I; Igual-Muñoz A Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4667-76. PubMed ID: 24094174 [TBL] [Abstract][Full Text] [Related]
17. Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants. Lewis AC; Kilburn MR; Papageorgiou I; Allen GC; Case CP J Biomed Mater Res A; 2005 Jun; 73(4):456-67. PubMed ID: 15900610 [TBL] [Abstract][Full Text] [Related]