212 related articles for article (PubMed ID: 31191711)
1. Finite Element Method Analysis of Compression Fractures on Whole-Spine Models Including the Rib Cage.
Nishida N; Ohgi J; Jiang F; Ito S; Imajo Y; Suzuki H; Funaba M; Nakashima D; Sakai T; Chen X
Comput Math Methods Med; 2019; 2019():8348631. PubMed ID: 31191711
[TBL] [Abstract][Full Text] [Related]
2. [Three-dimensional finite element model of thoracolumbar spine with osteoporotic vertebral compression fracture].
Fei Q; Li QJ; Yang Y; Li D; Tang H; Li JJ; Wang BQ; Wang YP
Zhonghua Yi Xue Za Zhi; 2010 Nov; 90(41):2943-6. PubMed ID: 21211403
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical evaluation of a simulated T-9 burst fracture of the thoracic spine with an intact rib cage.
Perry TG; Mageswaran P; Colbrunn RW; Bonner TF; Francis T; McLain RF
J Neurosurg Spine; 2014 Sep; 21(3):481-8. PubMed ID: 24949903
[TBL] [Abstract][Full Text] [Related]
4. Finite element analysis of compression fractures at the thoracolumbar junction using models constructed from medical images.
Nakashima D; Kanchiku T; Nishida N; Ito S; Ohgi J; Suzuki H; Imajo Y; Funaba M; Chen X; Taguchi T
Exp Ther Med; 2018 Apr; 15(4):3225-3230. PubMed ID: 29545839
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis.
Zhao WT; Qin DP; Zhang XG; Wang ZP; Tong Z
J Orthop Surg Res; 2018 Feb; 13(1):32. PubMed ID: 29422073
[TBL] [Abstract][Full Text] [Related]
6. The influence of the rib cage on the static and dynamic stability responses of the scoliotic spine.
Jia S; Lin L; Yang H; Fan J; Zhang S; Han L
Sci Rep; 2020 Oct; 10(1):16916. PubMed ID: 33037307
[TBL] [Abstract][Full Text] [Related]
7. [The effect of rib cage on the dynamic response stability of the scoliotic spine].
Yang H; Lin L; Zhang S; Tian T; Li Y; Han L
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2019 Oct; 36(5):769-776. PubMed ID: 31631625
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine.
Kayanja MM; Togawa D; Lieberman IH
Spine J; 2005; 5(1):55-63. PubMed ID: 15653085
[TBL] [Abstract][Full Text] [Related]
9. The unstable thoracic cage injury: The concomitant sternal fracture indicates a severe thoracic spine fracture.
Morgenstern M; von Rüden C; Callsen H; Friederichs J; Hungerer S; Bühren V; Woltmann A; Hierholzer C
Injury; 2016 Nov; 47(11):2465-2472. PubMed ID: 27592182
[TBL] [Abstract][Full Text] [Related]
10. Age-dependent factors affecting thoracic response: a finite element study focused on Japanese elderly occupants.
Antona-Makoshi J; Yamamoto Y; Kato R; Sato F; Ejima S; Dokko Y; Yasuki T
Traffic Inj Prev; 2015; 16 Suppl 1():S66-74. PubMed ID: 26027977
[TBL] [Abstract][Full Text] [Related]
11. A novel technique with reduced computed tomography exposure to predict vertebral compression fracture: a finite element study based on rat vertebrae.
Solitro GF; Mainnemare F; Amirouche F; Mehta A
Med Biol Eng Comput; 2019 Apr; 57(4):795-805. PubMed ID: 30402789
[TBL] [Abstract][Full Text] [Related]
12. [Establishment of a 3D finite element model of human thoracic cage and biomechanical analysis].
Shao Y; Huang P; Li ZD; Liu NG; Wan L; Zou DH; Chen YJ
Fa Yi Xue Za Zhi; 2013 Apr; 29(2):81-5. PubMed ID: 23930497
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.
Upasani VV; Robertson C; Lee D; Tomlinson T; Mahar AT
Spine (Phila Pa 1976); 2010 Sep; 35(19):1783-8. PubMed ID: 20098352
[TBL] [Abstract][Full Text] [Related]
14. Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion.
Jackman TM; Hussein AI; Curtiss C; Fein PM; Camp A; De Barros L; Morgan EF
J Bone Miner Res; 2016 Apr; 31(4):777-88. PubMed ID: 26590372
[TBL] [Abstract][Full Text] [Related]
15. Finite element modeling of the human thoracolumbar spine.
Liebschner MA; Kopperdahl DL; Rosenberg WS; Keaveny TM
Spine (Phila Pa 1976); 2003 Mar; 28(6):559-65. PubMed ID: 12642762
[TBL] [Abstract][Full Text] [Related]
16. Risk of vertebral compression fractures in multiple myeloma patients: A finite-element study.
Anitha D; Baum T; Kirschke JS; Subburaj K
Medicine (Baltimore); 2017 Jan; 96(2):e5825. PubMed ID: 28079810
[TBL] [Abstract][Full Text] [Related]
17. Effects of the rib cage on thoracic spine flexibility.
Sham ML; Zander T; Rohlmann A; Bergmann G
Biomed Tech (Berl); 2005 Nov; 50(11):361-5. PubMed ID: 16370149
[TBL] [Abstract][Full Text] [Related]
18. A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro.
Dall'Ara E; Schmidt R; Pahr D; Varga P; Chevalier Y; Patsch J; Kainberger F; Zysset P
J Biomech; 2010 Aug; 43(12):2374-80. PubMed ID: 20462582
[TBL] [Abstract][Full Text] [Related]
19. Biomechanics of thoracolumbar junction vertebral fractures from various kinematic conditions.
Fradet L; Petit Y; Wagnac E; Aubin CE; Arnoux PJ
Med Biol Eng Comput; 2014 Jan; 52(1):87-94. PubMed ID: 24165806
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of mono-segment transpedicular fixation with short-segment fixation for treatment of thoracolumbar fractures: a finite element analysis.
Xu G; Fu X; Du C; Ma J; Li Z; Tian P; Zhang T; Ma X
Proc Inst Mech Eng H; 2014 Oct; 228(10):1005-13. PubMed ID: 25267283
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]