These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Neutron irradiation-induced shutdown dose rate estimation in EU DEMO divertor. Stankunas G; Breidokaite S Appl Radiat Isot; 2024 Aug; 210():111363. PubMed ID: 38796996 [TBL] [Abstract][Full Text] [Related]
4. Activation analysis and evaluation of the radionuclide inventories, decay heat for European DEMO divertor components. Breidokaite S; Eade T; Berry T; Stankunas G; Tidikas A Appl Radiat Isot; 2022 Sep; 187():110314. PubMed ID: 35714517 [TBL] [Abstract][Full Text] [Related]
5. Monte Carlo characterization and benchmarking of extended range REM meters for its application in shielding and radiation area monitoring in Compact Proton Therapy Centers (CPTC). García-Fernández GF; Cevallos-Robalino LE; García-Baonza R; Gallego E; Vega-Carrillo HR; Guzman-García KA; Lorente A; Ibáñez S Appl Radiat Isot; 2019 Oct; 152():115-126. PubMed ID: 31295682 [TBL] [Abstract][Full Text] [Related]
6. Experiment and analyses for 14 MeV neutron streaming through a dogleg duct. Yamauchi M; Ochiai K; Morimoto Y; Wada M; Sato S; Nishitani T Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):542-6. PubMed ID: 16604695 [TBL] [Abstract][Full Text] [Related]
7. Neutronic analysis of IFMIF-DONES test cell cooling system. Stankunas G; Tidikas A Appl Radiat Isot; 2020 Sep; 163():109207. PubMed ID: 32392164 [TBL] [Abstract][Full Text] [Related]
8. Neutronics simulations for the design of neutron flux monitors in SPARC. Wang X; Gocht R; Ball J; Mackie S; Panontin E; Tinguely RA; Raj P; Holmes I; Saltos AA; Johnson A; Grieve A Rev Sci Instrum; 2024 Aug; 95(8):. PubMed ID: 39212507 [TBL] [Abstract][Full Text] [Related]
9. Analysis and improvement of cyclotron thallium target room shield. Hajiloo N; Raisali G; Aslani G Radiat Prot Dosimetry; 2008; 130(4):427-33. PubMed ID: 18417490 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of neutron and gamma dose in a new deuterium-deuterium fusion neutron generator facility using MCNP and experimental methods. Bergaoui K; Reguigui N; Brown C; Yousfi B; Nasri MA; Gary K Appl Radiat Isot; 2019 Apr; 146():90-98. PubMed ID: 30763820 [TBL] [Abstract][Full Text] [Related]
12. Measurements of neutron transport of well defined silicon filtered beam in lead. Košťál M; Schulc M; Šoltés J; Losa E; Viererbl L; Matěj Z; Cvachovec F; Rypar V Appl Radiat Isot; 2018 Dec; 142():160-166. PubMed ID: 30316130 [TBL] [Abstract][Full Text] [Related]
13. Advances, Challenges, and Future Perspectives of Microwave Reflectometry for Plasma Position and Shape Control on Future Nuclear Fusion Devices. Gonçalves B; Varela P; Silva A; Silva F; Santos J; Ricardo E; Vale A; Luís R; Nietiadi Y; Malaquias A; Belo J; Dias J; Ferreira J; Franke T; Biel W; Heuraux S; Ribeiro T; De Masi G; Tudisco O; Cavazzana R; Marchiori G; D'Arcangelo O Sensors (Basel); 2023 Apr; 23(8):. PubMed ID: 37112274 [TBL] [Abstract][Full Text] [Related]
14. Neutron production in tissue-like media and shielding materials irradiated with high-energy ion beams. Gudowska I; Kopec M; Sobolevsky N Radiat Prot Dosimetry; 2007; 126(1-4):652-6. PubMed ID: 17504751 [TBL] [Abstract][Full Text] [Related]
15. Compact shielding design of a portable Zhang F; Wu H; Wang X; Wu G; Jia W; Ti Y Appl Radiat Isot; 2017 Oct; 128():49-54. PubMed ID: 28688246 [TBL] [Abstract][Full Text] [Related]
16. Three-dimensional shielding calculations for the IFMIF neutron source using a coupled Monte Carlo/Deterministic computational scheme. Chen Y; Fischer U; Simakov SP; Wasastjerna F Radiat Prot Dosimetry; 2005; 115(1-4):573-9. PubMed ID: 16381788 [TBL] [Abstract][Full Text] [Related]
17. Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak. Du TF; Chen ZJ; Peng XY; Yuan X; Zhang X; Gorini G; Nocente M; Tardocchi M; Hu ZM; Cui ZQ; Xie XF; Ge LJ; Hu LQ; Zhong GQ; Lin SY; Wan BN; Li XQ; Zhang GH; Chen JX; Fan TS Rev Sci Instrum; 2014 Nov; 85(11):11E115. PubMed ID: 25430294 [TBL] [Abstract][Full Text] [Related]
18. Overview of the neutron diagnostic systems for the SPARC tokamak. Raj P; Ball JL; Carmichael J; Frenje JA; Gocht R; Gorini G; Holmes I; Johnson MG; Kennedy R; Mackie S; Nocente M; Panontin E; Petruzzo M; Rebai M; Reinke M; Rice J; Rigamonti D; Rosa MD; Saltos AA; Tardocchi M; Tinguely RA; Wang X Rev Sci Instrum; 2024 Oct; 95(10):. PubMed ID: 39356194 [TBL] [Abstract][Full Text] [Related]
19. Shielding and radiation safety around a superconducting cyclotron neutron therapy facility. Yudelev M; Maughan RL; Dunlap K Health Phys; 1995 Jul; 69(1):130-6. PubMed ID: 7790207 [TBL] [Abstract][Full Text] [Related]
20. Shielding materials in the compact spherical tokamak. Humphry-Baker SA; Smith GDW Philos Trans A Math Phys Eng Sci; 2019 Mar; 377(2141):20170443. PubMed ID: 30967055 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]