These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

549 related articles for article (PubMed ID: 31197915)

  • 1. False-negative rate of ultrasound-guided fine-needle aspiration cytology for identifying axillary lymph node metastasis in breast cancer patients.
    Kane G; Fleming C; Heneghan H; McCartan D; James P; Trueick R; Harrington L; Nally F; Quinn C; O'Doherty A; McNally S; Rothwell J; Evoy D; Geraghty J; McDermott E; Prichard R
    Breast J; 2019 Sep; 25(5):848-852. PubMed ID: 31197915
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound and fine needle aspiration cytology of axillary lymph nodes in breast cancer. To do or not to do?
    Leenders MW; Broeders M; Croese C; Richir MC; Go HL; Langenhorst BL; Meijer S; Schreurs WH
    Breast; 2012 Aug; 21(4):578-83. PubMed ID: 22717665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Initial axillary staging of breast cancer using ultrasound-guided fine needle aspiration: a liquid-based cytology study.
    Schiettecatte A; Bourgain C; Breucq C; Buls N; De Wilde V; de Mey J
    Cytopathology; 2011 Feb; 22(1):30-5. PubMed ID: 20337693
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axillary Staging of Early-Stage Invasive Breast Cancer by Ultrasound-Guided Fine-Needle Aspiration Cytology: Which Ultrasound Criteria for Classifying Abnormal Lymph Nodes Should Be Adopted in the Post-ACOSOG Z0011 Trial Era?
    Zhu Y; Zhou W; Zhou JQ; Fei XC; Ye TJ; Huang O; Chen XS; Zhan WW
    J Ultrasound Med; 2016 May; 35(5):885-93. PubMed ID: 27009312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of ultrasound-guided fine-needle aspiration of indeterminate and suspicious axillary lymph nodes in the initial staging of breast carcinoma.
    Krishnamurthy S; Sneige N; Bedi DG; Edieken BS; Fornage BD; Kuerer HM; Singletary SE; Hunt KK
    Cancer; 2002 Sep; 95(5):982-8. PubMed ID: 12209680
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The clinical utility of combining pre-operative axillary ultrasonography and fine needle aspiration cytology with radionuclide guided sentinel lymph node biopsy in breast cancer patients with palpable axillary lymph nodes.
    Usmani S; Ahmed N; Al Saleh N; abu Huda F; Amanguno HG; Amir T; al Kandari F
    Eur J Radiol; 2015 Dec; 84(12):2515-20. PubMed ID: 26474908
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axillary staging by ultrasound-guided fine-needle aspiration cytology in breast cancer patients. Still up to date?
    Leenders M; Richir M; Broeders M; Moormann G; Mollema R; Lopes Cardozo A; Meijer S; Schreurs H
    Breast J; 2013; 19(6):637-42. PubMed ID: 24011125
    [TBL] [Abstract][Full Text] [Related]  

  • 8. To Evaluate the Accuracy of Axillary Staging Using Ultrasound and Ultrasound-Guided Fine-Needle Aspiration Cytology (USG-FNAC) in Early Breast Cancer Patients-a Prospective Study.
    Singh R; Deo SVS; Dhamija E; Mathur S; Thulkar S
    Indian J Surg Oncol; 2020 Dec; 11(4):726-734. PubMed ID: 33281412
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preoperative axillary nodal staging of invasive lobular breast cancer with ultrasound guided fine needle aspiration in patients with suspicious ultrasound findings versus aspiration in all patients - A retrospective single institutional analysis.
    Cserni G; Ambrózay É; Serényi P; Bori R; Sejben I; Csörgő E; Serfőző O; Lóránd K; Venczel L; Maráz R; Sinkó M; Szeleczki N; Nyári T; Zombori T
    Eur J Surg Oncol; 2022 Apr; 48(4):742-747. PubMed ID: 34872778
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Axillary ultrasound and Fine-Needle Aspiration Cytology in the preoperative staging of axillary node metastasis in breast cancer patients.
    Gipponi M; Fregatti P; Garlaschi A; Murelli F; Margarino C; Depaoli F; Baccini P; Gallo M; Friedman D
    Breast; 2016 Dec; 30():146-150. PubMed ID: 27728855
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cost/accuracy ratio analysis in breast cancer patients undergoing ultrasound-guided fine-needle aspiration cytology, sentinel node biopsy, and frozen section of node.
    Genta F; Zanon E; Camanni M; Deltetto F; Drogo M; Gallo R; Gilardi C
    World J Surg; 2007 Jun; 31(6):1155-63. PubMed ID: 17464539
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Axillary dissection in patients with preoperative positive nodal cytology: Genuine need or overtreatment?
    Liberale V; Rosso R; Arisio R; D'Alonzo M; Villasco A; Fuso L; De Sanctis C; Modaffari P; Biglia N
    Breast J; 2020 Feb; 26(2):168-175. PubMed ID: 31448500
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is ultrasound-guided fine-needle aspiration cytology of adequate value in detecting breast cancer patients with three or more positive axillary lymph nodes?
    Kramer GM; Leenders MW; Schijf LJ; Go HL; van der Ploeg T; van den Tol MP; Schreurs WH
    Breast Cancer Res Treat; 2016 Apr; 156(2):271-8. PubMed ID: 26995283
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound-Guided Fine-Needle Aspiration of Non-palpable and Suspicious Axillary Lymph Nodes with Subsequent Removal after Tattooing: False-Negative Results and Concordance with Sentinel Lymph Nodes.
    Kim WH; Kim HJ; Jung JH; Park HY; Lee J; Kim WW; Park JY; Cheon H; Lee SM; Cho SH; Shin KM; Kim GC
    Ultrasound Med Biol; 2017 Nov; 43(11):2576-2581. PubMed ID: 28830644
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic Accuracy Of Us-Fnac Of Axillary Lymph Nodes In Patients With Primary Breast Cancer Using Sentinel Lymph Node Biopsy As Standard Reference.
    Fayyaz MB; Niazi IK
    J Ayub Med Coll Abbottabad; 2019; 31(2):242-247. PubMed ID: 31094125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasound-guided fine-needle aspiration of axillary lymph nodes in breast cancer: Diagnostic accuracy and role in surgical management.
    Iwamoto N; Aruga T; Horiguchi S; Asami H; Saita C; Onishi M; Goto R; Ishiba T; Honda Y; Miyamoto H; Kuroi K
    Diagn Cytopathol; 2019 Aug; 47(8):788-792. PubMed ID: 31041851
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Axillary node staging by ultrasonography and fine-needle aspiration cytology in patients with breast cancer.
    Baruah BP; Goyal A; Young P; Douglas-Jones AG; Mansel RE
    Br J Surg; 2010 May; 97(5):680-3. PubMed ID: 20186888
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pre-operative axillary ultrasound with fine-needle aspiration cytology performance and predictive factors of false negatives in axillary lymph node involvement in early breast cancer.
    Hotton J; Salleron J; Henrot P; Buhler J; Leufflen L; Rauch P; Marchal F
    Breast Cancer Res Treat; 2020 Oct; 183(3):639-647. PubMed ID: 32737710
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of preoperative axillary ultrasound and fine-needle aspiration cytology in identifying patients with extensive axillary lymph node involvement.
    Maráz R; Zombori T; Ambrózay É; Cserni G
    Eur J Surg Oncol; 2017 Nov; 43(11):2021-2028. PubMed ID: 28919032
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The role of preoperative axillary lymph node fine needle aspiration in locoregional staging of breast cancer.
    Sauer T; Suciu V
    Ann Pathol; 2012 Dec; 32(6):e24-8, 410-4. PubMed ID: 23244481
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.