These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 31201528)

  • 21. Effects of motion on the performance of pulse oximeters in volunteers.
    Barker SJ; Shah NK
    Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients.
    Harskamp RE; Bekker L; Himmelreich JCL; De Clercq L; Karregat EPM; Sleeswijk ME; Lucassen WAM
    BMJ Open Respir Res; 2021 Sep; 8(1):. PubMed ID: 34489238
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of accuracy of portable fingertip pulse oximeter, as compared to that of a hospital oximeter with digital sensor.
    Pupim D; Iwaki Filho L; Takeshita WM; Iwaki LC
    Indian J Dent Res; 2013; 24(5):542-6. PubMed ID: 24355951
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.
    Takatani S; Davies C; Sakakibara N; Zurick A; Kraenzler E; Golding LR; Noon GP; Nose Y; DeBakey ME
    J Clin Monit; 1992 Oct; 8(4):257-66. PubMed ID: 1453185
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.
    Mendelson Y; McGinn MJ
    J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
    Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
    Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Research: Comparison of the Accuracy of a Pocket versus Standard Pulse Oximeter.
    da Costa JC; Faustino P; Lima R; Ladeira I; Guimarães M
    Biomed Instrum Technol; 2016; 50(3):190-3. PubMed ID: 27164204
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of a new pulse oximeter sensor.
    Fernandez M; Burns K; Calhoun B; George S; Martin B; Weaver C
    Am J Crit Care; 2007 Mar; 16(2):146-52. PubMed ID: 17322015
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of Pulse Oximetry and Handheld Doppler for Assessing Digital Perfusion.
    Jimenez ML; Matzon JL; Lutsky KF
    Bull Hosp Jt Dis (2013); 2019 Mar; 77(2):128-131. PubMed ID: 31128582
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Accuracy of pulse oximeters in measuring oxygen saturation in patients with poor peripheral perfusion: a systematic review.
    Poorzargar K; Pham C; Ariaratnam J; Lee K; Parotto M; Englesakis M; Chung F; Nagappa M
    J Clin Monit Comput; 2022 Aug; 36(4):961-973. PubMed ID: 35119597
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A prototype device for standardized calibration of pulse oximeters II.
    Hornberger Ch; Knoop P; Matz H; Dörries F; Konecny E; Gehring H; Otten J; Bonk R; Frankenberger H; Wouters P; Gil-Rodriguez J; Ponz L; Avgerinos J; Karoutis A; Ikiades A; Weininger S
    J Clin Monit Comput; 2002; 17(3-4):203-9. PubMed ID: 12455737
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Precision and accuracy of "a pocket" pulse oximeter in Mexico City].
    Torre-Bouscoulet L; Chávez-Plascencia E; Vázquez-García JC; Pérez-Padilla R
    Rev Invest Clin; 2006; 58(1):28-33. PubMed ID: 16789596
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ambulatory oximetry monitoring in patients with severe COPD: a preliminary study.
    Pilling J; Cutaia M
    Chest; 1999 Aug; 116(2):314-21. PubMed ID: 10453857
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Novel wearable and wireless ring-type pulse oximeter with multi-detectors.
    Huang CY; Chan MC; Chen CY; Lin BS
    Sensors (Basel); 2014 Sep; 14(9):17586-99. PubMed ID: 25244586
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Accuracy and Reliability of Commercial Wrist-Worn Pulse Oximeter During Normobaric Hypoxia Exposure Under Resting Conditions.
    Lauterbach CJ; Romano PA; Greisler LA; Brindle RA; Ford KR; Kuennen MR
    Res Q Exerc Sport; 2021 Sep; 92(3):549-558. PubMed ID: 32633688
    [No Abstract]   [Full Text] [Related]  

  • 37. Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.
    Cheng EY; Hopwood MB; Kay J
    J Clin Monit; 1988 Jul; 4(3):223-6. PubMed ID: 3210070
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of a New Pulse Oximetry in Detection of Arterial Oxygen Saturation and Heart Rate Measurements: The SOMBRERO Study.
    Marinari S; Volpe P; Simoni M; Aventaggiato M; De Benedetto F; Nardini S; Sanguinetti CM; Palange P
    Sensors (Basel); 2022 Jul; 22(13):. PubMed ID: 35808526
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Correspondence to: performance of the new SmartCardia wireless, wearable oximeter: a comparison with arterial SaO2 in healthy volunteers.
    Barker SJ; Wilson WC
    BMC Anesthesiol; 2022 Sep; 22(1):303. PubMed ID: 36163005
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients.
    Van Ginderdeuren F; Van Cauwelaert K; Malfroot A
    J Cyst Fibros; 2006 May; 5(2):125-8. PubMed ID: 16504602
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.