213 related articles for article (PubMed ID: 31208105)
1. Particle Image Velocimetry of Oil-Water Two-Phase Flow with High Water Cut and Low Flow Velocity in a Horizontal Small-Diameter Pipe.
Han L; Wang H; Liu X; Xie R; Mu H; Fu C
Sensors (Basel); 2019 Jun; 19(12):. PubMed ID: 31208105
[TBL] [Abstract][Full Text] [Related]
2. Ultrasonic particle image velocimetry for improved flow gradient imaging: algorithms, methodology and validation.
Niu L; Qian M; Wan K; Yu W; Jin Q; Ling T; Gao S; Zheng H
Phys Med Biol; 2010 Apr; 55(7):2103-20. PubMed ID: 20299721
[TBL] [Abstract][Full Text] [Related]
3. Echo particle image velocimetry.
DeMarchi N; White C
J Vis Exp; 2012 Dec; (70):. PubMed ID: 23299186
[TBL] [Abstract][Full Text] [Related]
4. Time-Resolved Particle Image Velocimetry Measurements with Wall Shear Stress and Uncertainty Quantification for the FDA Nozzle Model.
Raben JS; Hariharan P; Robinson R; Malinauskas R; Vlachos PP
Cardiovasc Eng Technol; 2016 Mar; 7(1):7-22. PubMed ID: 26628081
[TBL] [Abstract][Full Text] [Related]
5. Inter-Laboratory Characterization of the Velocity Field in the FDA Blood Pump Model Using Particle Image Velocimetry (PIV).
Hariharan P; Aycock KI; Buesen M; Day SW; Good BC; Herbertson LH; Steinseifer U; Manning KB; Craven BA; Malinauskas RA
Cardiovasc Eng Technol; 2018 Dec; 9(4):623-640. PubMed ID: 30291585
[TBL] [Abstract][Full Text] [Related]
6. Flow velocity vector fields by ultrasound particle imaging velocimetry: in vitro comparison with optical flow velocimetry.
Westerdale J; Belohlavek M; McMahon EM; Jiamsripong P; Heys JJ; Milano M
J Ultrasound Med; 2011 Feb; 30(2):187-95. PubMed ID: 21266556
[TBL] [Abstract][Full Text] [Related]
7. Enhancement of measurement accuracy of X-ray PIV in comparison with the micro-PIV technique.
Park H; Jung SY; Park JH; Kim JH; Lee SJ
J Synchrotron Radiat; 2018 Mar; 25(Pt 2):552-559. PubMed ID: 29488936
[TBL] [Abstract][Full Text] [Related]
8. Meta-Lens Particle Image Velocimetry.
Liu X; Zhao Z; Xu S; Zhang J; Zhou Y; He Y; Yamaguchi T; Ouyang H; Tanaka T; Chen MK; Shi S; Qi F; Tsai DP
Adv Mater; 2024 Apr; 36(17):e2310134. PubMed ID: 38042993
[TBL] [Abstract][Full Text] [Related]
9. Velocimetry based on dye visualization for a pulsatile tubing flow measurement.
Yang Z; Johnson M
Appl Opt; 2019 Apr; 58(10):C7-C13. PubMed ID: 31045025
[TBL] [Abstract][Full Text] [Related]
10. A Differential Pressure Sensor Coupled with Conductance Sensors to Evaluate Pressure Drop Prediction Models of Gas-Water Two-Phase Flow in a Vertical Small Pipe.
Deng YR; Jin ND; Yang QY; Wang DY
Sensors (Basel); 2019 Jun; 19(12):. PubMed ID: 31213018
[TBL] [Abstract][Full Text] [Related]
11. A dual-phantom system for validation of velocity measurements in stenosis models under steady flow.
Blake JR; Easson WJ; Hoskins PR
Ultrasound Med Biol; 2009 Sep; 35(9):1510-24. PubMed ID: 19540655
[TBL] [Abstract][Full Text] [Related]
12. High dynamic velocity range particle image velocimetry using multiple pulse separation imaging.
Persoons T; O'Donovan TS
Sensors (Basel); 2011; 11(1):1-18. PubMed ID: 22346564
[TBL] [Abstract][Full Text] [Related]
13. Quantitative flow analysis around aquatic animals using laser sheet particle image velocimetry.
Stamhuis E; Videler J
J Exp Biol; 1995; 198(Pt 2):283-94. PubMed ID: 9317812
[TBL] [Abstract][Full Text] [Related]
14. [Two-dimensional measurement of blood flow velocity in rat arteries based on ultrasonic particle image velocimetry].
Zhu Y; Qian M; Niu L; Zheng H; Lu G
Nan Fang Yi Ke Da Xue Xue Bao; 2014 Aug; 34(9):1305-9. PubMed ID: 25263364
[TBL] [Abstract][Full Text] [Related]
15. A tracer liquid image velocimetry for multi-layer radial flow in bioreactors.
Gao YB; Liang JX; Luo YX; Yan J
Biomed Eng Online; 2015 Feb; 14():10. PubMed ID: 25888748
[TBL] [Abstract][Full Text] [Related]
16. Echo Particle Image Velocimetry for Estimation of Carotid Artery Wall Shear Stress: Repeatability, Reproducibility and Comparison with Phase-Contrast Magnetic Resonance Imaging.
Gurung A; Gates PE; Mazzaro L; Fulford J; Zhang F; Barker AJ; Hertzberg J; Aizawa K; Strain WD; Elyas S; Shore AC; Shandas R
Ultrasound Med Biol; 2017 Aug; 43(8):1618-1627. PubMed ID: 28501327
[TBL] [Abstract][Full Text] [Related]
17. Error Propagation Dynamics of PIV-based Pressure Field Calculations: How well does the pressure Poisson solver perform inherently?
Pan Z; Whitehead J; Thomson S; Truscott T
Meas Sci Technol; 2016 Aug; 27(8):084012. PubMed ID: 27499587
[TBL] [Abstract][Full Text] [Related]
18. Three-dimensional measurement and visualization of internal flow of a moving droplet using confocal micro-PIV.
Kinoshita H; Kaneda S; Fujii T; Oshima M
Lab Chip; 2007 Mar; 7(3):338-46. PubMed ID: 17330165
[TBL] [Abstract][Full Text] [Related]
19. Visualization of bubble-fluid interaction by a moving object flow image analyzer system.
Choi HM; Terauchi T; Monji H; Matsui G
Ann N Y Acad Sci; 2002 Oct; 972():235-41. PubMed ID: 12496023
[TBL] [Abstract][Full Text] [Related]
20. Echocardiographic particle image velocimetry: a novel technique for quantification of left ventricular blood vorticity pattern.
Kheradvar A; Houle H; Pedrizzetti G; Tonti G; Belcik T; Ashraf M; Lindner JR; Gharib M; Sahn D
J Am Soc Echocardiogr; 2010 Jan; 23(1):86-94. PubMed ID: 19836203
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]